Skip to Content
Merck

MGT

mPAGE® Mini Gel Tank

for electrophoresis of precast gels or hand cast polyacrylamide gels

Synonym(s):

mini gel tank

Sign In to View Organizational & Contract Pricing.

Select a Size

1 EA

₩816,771

1 EA

₩1,107,873

₩816,771


Estimated to ship onMarch 30, 2026Details



About This Item

NACRES:
NC.01
UNSPSC Code:
41105340

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

AC/DC input

100 watts (maximum power limit), 300 V (maximum voltage limit)

manufacturer/tradename

Millipore

packaging

1 ea of (for running 2 or 4 gels)

parameter

70 °C ambient temp. limit

technique(s)

SDS-PAGE: suitable, electrophoresis: suitable

L × W × H

17 cm × 13.5 cm × 15.5 cm, tank and lid

buffer volume

1265 mL , Primary and secondary core (4 gels), 790 mL , Primary core (2 gels)

tank L × W × H

17 cm × 13 cm × 15.5 cm

compatibility

for use with mPAGE®

  • Gels cast with mPage® Gel Caster
  • Other precast gels with cassette dimension 8 x 10 cm
  • mPAGE® Bis-Tris Precast Gels
  • mPAGE® Mini Wet Transfer System

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
GCR2MSPA15MSPA10
technique(s)

SDS-PAGE: suitable, electrophoresis: suitable

technique(s)

SDS-PAGE: suitable, electrophoresis: suitable

technique(s)

SDS-PAGE: suitable, electrophoresis: suitable

technique(s)

SDS-PAGE: suitable, electrophoresis: suitable

packaging

1 ea of (for running 2 or 4 gels)

packaging

pack of 2

packaging

pkg of 5 packs

packaging

pkg of 5 packs

AC/DC input

100 watts (maximum power limit), 300 V (maximum voltage limit)

AC/DC input

-

AC/DC input

-

AC/DC input

-

manufacturer/tradename

Millipore

manufacturer/tradename

Millipore

manufacturer/tradename

Millipore

manufacturer/tradename

Millipore

parameter

70 °C ambient temp. limit

parameter

-

parameter

-

parameter

-

L × W × H

17 cm × 13.5 cm × 15.5 cm, tank and lid

L × W × H

-

L × W × H

-

L × W × H

-

General description

The mPAGE® Mini Gel Tank is used to perform high-resolution protein separation on handcast or precast polyacrylamide gels. The gel tank is designed for use with 8 cm x 10 cm mini gels and is compatible with gels cast on the mPAGE® Gel Caster and mPAGE® Precast Gels. The mPAGE® Mini Gel Tank is available in 2 formats for running up to 2 or 4 mini gels and is designed to prevent incorrect assembly and leakage.

Other Notes

2-gel tank includes
  • mPAGE® Tank Lid with Electrode Cables (1)
  • mPAGE® Replacement Tank (1)
  • mPAGE® Primary Electrode Core (1)
  • mPAGE® Buffer Dam (1)
  • mPAGE® Gel Releasers (5)
4-gel tank includes
  • mPAGE® Tank Lid with Electrode Cables (1)
  • mPAGE® Replacement Tank (1)
  • mPAGE® Primary Electrode Core (1)
  • mPAGE® Secondary Electrode Core (1)
  • mPAGE® Buffer Dam (1)
  • mPAGE® Gel Releasers (5)

Legal Information

MPAGE is a registered trademark of Merck KGaA, Darmstadt, Germany

related product

Product No.
Description
Pricing

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Articles

Understand the importance of using high-quality water in protein electrophoresis and Western blotting to improve assay sensitivity and accuracy.

mPAGE® Lux 캐스팅 시스템으로 3분 만에 바로 사용 가능한 SDS-PAGE 겔로 겔 캐스팅 워크플로우를 새롭게 하세요. 더 간단하고 안전한 겔 캐스팅 방법을 찾아보세요.

Refresh your gel casting workflow with ready-to-use SDS-PAGE gels in just 3 minutes with the mPAGE® Lux Casting System. Find simpler, safer gel casting methods.

Protocols

PAGE 소개. 폴리아크릴아미드 겔에서의 크기 기준 단백질 분리를 위한 SDS-PAGE 배경 및 프로토콜에 대해 알아봅니다.

Introduction to PAGE. Learn about SDS-PAGE background and protocol for the separation of proteins based on size in a poly-acrylamide gel.

Related Content

We get it. Westerns can be a pain in the blot, and we’ve certainly made our share. So, share with us your ugly blots and receive a surprise! And while we can’t tell you what it is – that would spoil the surprise - except that it will spark creativity in the lab.

이해합니다. 서양인들은 얼룩으로 인해 고통스러울 수 있으며, 저희도 확실히 그 고통을 겪었습니다. 그러니 여러분의 못생긴 오점을 공유해 주시고 깜짝 선물을 받아보세요! 깜짝 선물이 무엇인지 알려드릴 수는 없지만, 실험실에서 창의력을 자극할 수 있다는 점만 말씀드릴 수 있습니다.

Questions

  1. Is the MGT (mPAGE® Mini Gel Tank) compatible with NuPAGE Gel?

    1 answer
    1. The MGT-2 tank is incompatible with NuPAGE gels due to their taller size, which exceeds the capacity of the MGT-2. Additionally, the outlet of the NuPAGE gels is positioned on the side, while the closure system of the MGT-2 requires an outlet at the bottom.

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service