Skip to Content
Merck
  • Xanthine derivatives quantification in serum by capillary zone electrophoresis.

Xanthine derivatives quantification in serum by capillary zone electrophoresis.

Journal of chromatographic science (2013-11-14)
Juan Peris-Vicente, Maria Rambla-Alegre, Abhilasha Durgavanshi, Devasish Bose, Josep Esteve-Romero, Sergio Marco-Peiró
ABSTRACT

A capillary electrophoresis method was developed to quantify caffeine and theophylline, xanthine derivatives with bronchodilator activity. Buffer concentration, pH and applied voltage were optimized using a central composite design-face centred. Separation conditions were: silica capillary tube, 75 μm (i.d.) and 61 cm (total length); absorbance detection, 280 nm; borate buffer, 20 mM, pH 9.0; applied voltage, 25 kV and 1 psi injection/8 s. Validation was performed in blank serum following the International Conference Harmonization guidelines: resolution (peaks without overlapping), linear range (0.125-50 µg/mL; r(2) > 0.9999), limits of detection and quantification (10; 20 and 33; 66 ppb for caffeine and theophylline, respectively), intra- and inter-day precision (Relative standard deviation lower than 1.9%) and accuracy (98-101%). Migration times were <8 min. This method is simple, specific and suitable and reaches high label claims (98.7-100.4%) in pharmaceutical formulations analysis. Moreover, the method was applied to the monitoring of the analytes in serum of patients.

MATERIALS
Product Number
Brand
Product Description

Millipore
Bifido Selective Supplement B, suitable for microbiology
Supelco
5α-Androstan-17β-ol-3-one, VETRANAL®, analytical standard
Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Sigma-Aldrich
Caffeine, anhydrous, 99%, FCC, FG
Supelco
Benalaxyl-M, PESTANAL®, analytical standard
Supelco
Caffeine Melting Point Standard, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Caffeine, Pharmaceutical Secondary Standard; Certified Reference Material
USP
Caffeine melting point standard, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
ACES, BioUltra, ≥99.5% (T)
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, purum, ≥99.0% (TLC)
Sigma-Aldrich
Caffeine, anhydrous, tested according to Ph. Eur.
Sigma-Aldrich
Boric acid, 99.999% trace metals basis
Supelco
Mettler-Toledo Calibration substance ME 18872, Caffeine, traceable to primary standards (LGC)
Sigma-Aldrich
Boric acid, 99.97% trace metals basis
Sigma-Aldrich
ACES, ≥99.0% (titration)
Sigma-Aldrich
ACES, BioXtra, ≥99.0% (titration)
Sigma-Aldrich
Caffeine, meets USP testing specifications, anhydrous
Sigma-Aldrich
Boric acid, BioReagent, Molecular Biology, suitable for cell culture, suitable for plant cell culture, ≥99.5%
Sigma-Aldrich
Boric acid, tablet, 1 g boric acid per tablet
Sigma-Aldrich
Caffeine, BioXtra
Sigma-Aldrich
Caffeine, powder, ReagentPlus®
Sigma-Aldrich
Caffeine, Sigma Reference Standard, vial of 250 mg
Sigma-Aldrich
Boric acid, suitable for electrophoresis, ≥99.5%
Sigma-Aldrich
ACES, BioPerformance Certified, ≥99.0%, suitable for cell culture
Sigma-Aldrich
5α-Androstan-17β-ol-3-one, ≥97.5%
Sigma-Aldrich
Boric acid, BioXtra, ≥99.5%
Supelco
Caffeine, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland
Caffeine, European Pharmacopoeia (EP) Reference Standard
USP
Glacial acetic acid, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Boric acid, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., buffer substance, ≥99.8%