Skip to Content
Merck

NA0200

GenElute HP Plasmid Midiprep Kit

greener alternative

sufficient for 25 purifications

Synonym(s):

GenElute HP Plasmid Midiprep Kit, plasmid extraction kit, plasmid isolation kit, plasmid purification kit, Gen Elute

Sign In to View Organizational & Contract Pricing.

Select a Size

1 KIT

MXP 8,098.00

MXP 8,098.00


Check Cart for Availability


About This Item

NACRES:
NA.52
UNSPSC Code:
41105501

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Product Name

GenElute HP Plasmid Midiprep Kit, sufficient for 25 purifications

usage

sufficient for 25 purifications

greener alternative product characteristics

Designing Safer Chemicals
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

technique(s)

DNA purification: suitable

Quality Level

test parameters

sample volume: 1-5 mL bacterial culture

greener alternative category

storage temp.

15-25°C

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
PLD35PLED35NA0300
technique(s)

DNA purification: suitable

technique(s)

DNA purification: suitable

technique(s)

DNA purification: suitable

technique(s)

DNA purification: suitable

usage

sufficient for 25 purifications

usage

sufficient for 35 purifications

usage

sufficient for 35 purifications

usage

sufficient for 10 purifications

greener alternative product characteristics

Designing Safer Chemicals
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Inherently Safer Chemistry for Accident Prevention
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Inherently Safer Chemistry for Accident Prevention
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Designing Safer Chemicals
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

sustainability

Greener Alternative Product

NA0200S

-

-

NA0300S, NA0310

greener alternative category

, Aligned

greener alternative category

Aligned,

greener alternative category

Aligned,

greener alternative category

Aligned,

General description

We are committed to bringing you Greener Alternative Products, which adhere to one or more of The 12 Principles of Greener Chemistry. This product has Inherently Safer Chemistry, compared to the standard use of phenol and chloroform to perform DNA extractions.
The GenElute HP Plasmid Midiprep Purification kits offer an ultrafast and efficient solution for large-scale plasmid preparation from E. coli cultures. These kits combine silica-based membrane technology and the convenience of spin or vacuum format. The kits also include a special filter cartridge, which replaces the centrifugation step following alkaline lysis. Following lysis the DNA is bound to the silica membrane and contaminants are removed with a simple wash step. The DNA is then eluted in water or TE buffer by centrifugation.

The purified plasmid DNA is suitable for a wide variety of molecular biology applications, including restriction digestions and sequencing.

Other Notes

For additional information, please see www.sigma-aldrich.com/genelutehp.

Legal Information

GenElute is a trademark of Sigma-Aldrich Co. LLC

Application

GenElute HP Plasmid Midiprep Kit has been used to isolate and purify plasmids.[1][2]

Features and Benefits

  • From harvested bacterial culture to pure plasmid DNA in 30 minutes or less
  • Up to 350 μg of high-copy plasmid DNA
  • Flexibility of a vacuum or spin format
  • No phenol/chloroform extraction or alcohol precipitation required
  • Contains fewer plastic components, reducing the amount of waste

Kit Components Also Available Separately

Product No.
Description
SDS

  • R1149Resuspension Solution, Add RNase A before use. After addition of RNAse, store at 2-8ºC. )SDS

  • W0263Wash Solution 1SDS

  • W4639Wash Solution 2SDS

  • R6148RNase A solutionSDS

  • C2112Column Preparation SolutionSDS

  • L1912Lysis SolutionSDS

signalword

Danger

target_organs

Central nervous system

Storage Class

3 - Flammable liquids

wgk

WGK 3

Hazard Classifications

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Dam. 1 - Flam. Liq. 3 - Met. Corr. 1 - Resp. Sens. 1 - Skin Corr. 1B - STOT SE 3


Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Genome-wide CRISPR screens reveal a Wnt-FZD5 signaling circuit as a druggable vulnerability of RNF43-mutant pancreatic tumors.
Steinhart Z
Nature Medicine, 23(1), 60-68 (2017)
Vanessa E Gray et al.
G3 (Bethesda, Md.), 9(11), 3683-3689 (2019-09-29)
Despite the importance of Aβ aggregation in Alzheimer's disease etiology, our understanding of the sequence determinants of aggregation is sparse and largely derived from in vitro studies. For example, in vitro proline and alanine scanning mutagenesis of Aβ40 proposed core
The distal upstream promoter in Ly49 genes, Pro1, is active in mature NK cells and T cells, does not require TATA boxes, and displays enhancer activity.
Gays F
Journal of Immunology, 194(12), 6068-6081 (2015)
Stephanie P Cartwright et al.
BMC research notes, 10(1), 340-340 (2017-07-29)
Patients with dual hepatitis B (HBV) and hepatitis D (HDV) virus infection are at an increased risk of progression to liver cirrhosis and hepatocellular carcinoma than patients with a single viral infection. Treatment of viral hepatitis due to dual HBV/HDV
Melissa A Chiasson et al.
eLife, 9 (2020-09-02)
Vitamin K epoxide reductase (VKOR) drives the vitamin K cycle, activating vitamin K-dependent blood clotting factors. VKOR is also the target of the widely used anticoagulant drug, warfarin. Despite VKOR's pivotal role in coagulation, its structure and active site remain

Related Content

Resumen de las técnicas habituales y las aplicaciones posteriores de la extracción y purificación del ADN genómico, el ADN plasmídico y el ARN total de células, tejidos, sangre, virus y otros tipos de muestra.

Overview of common techniques and downstream applications for extraction and purification of genomic DNA, plasmid DNA, and total RNA from cells, tissue, blood, viruses, and other sample types.

Tools for plasmid preparation, in vitro transcription, mRNA purification, and LNP formulation in mRNA-based vaccine and therapeutic development.

See All

Questions

1–6 of 6 Questions  
  1. How do the GenElute HP Plasmid Kits differ from other plasmid purification systems?

    1 answer
    1. The GenElute HP Plasmid Kits are much faster than other commercially available kits. A filter syringe is used for preparing the cleared lysate, which replaces a lengthy centrifugation step. These kits also offer the option of using a vacuum or spin purification format rather than a gravity drip to bind, wash and elute the plasmid. In addition, samples are eluted in Tris buffer so there are no alcohol precipitations required.

      Helpful?

  2. What is the expected yield of plasmid DNA that you can isolate from these kits?

    1 answer
    1. Yields can reach as high as 350 mg for a midiprep and 1.2 mg for a maxiprep. As with any protocol, lower yields can be expected with low copy plasmids.

      Helpful?

  3. Is plasmid DNA isolated with this kit suitable for use in transfection?

    1 answer
    1. Yes. However, if you are currently required to use an endofree plasmid purification kit, we recommend using the GenElute HP Endotoxin-free Kit.

      Helpful?

  4. How long does it take to isolate plasmid using the vacuum format?

    1 answer
    1. A midiprep or maxiprep requires only 30 minutes to complete.

      Helpful?

  5. Which format gives a better yield, vacuum or spin?

    1 answer
    1. There is no difference in plasmid recovery when using either format.

      Helpful?

  6. Do the binding columns fit on other manufacturers’ manifolds?

    1 answer
    1. Yes. The columns fit on all standard vacuum manifolds.

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service