Saltar al contenido
Merck

267503

Sigma-Aldrich

Titanium

foil, thickness 0.25 mm, 99.7% trace metals basis

Titanium
Slide 1 of 1
Iniciar sesiónpara Ver la Fijación de precios por contrato y de la organización

Seleccione un Tamaño

1 EA
MXP 2,991.00

MXP 2,991.00


Disponible para enviar HOYDetalles


Solicite una orden a granel

Acerca de este artículo

Fórmula empírica (notación de Hill):
Ti
Número CAS:
Peso molecular:
47.87
EC Number:
MDL number:
UNSPSC Code:
12141746
PubChem Substance ID:
NACRES:
NA.23

Saltar a


Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarle

Quality Level

assay

99.7% trace metals basis

form

foil

autoignition temp.

860 °F

resistivity

42.0 μΩ-cm, 20°C

thickness

0.25 mm

bp

3287 °C (lit.)

mp

1660 °C (lit.)

density

4.5 g/mL at 25 °C (lit.)

application(s)

battery manufacturing

SMILES string

[Ti]

InChI

1S/Ti

InChI key

RTAQQCXQSZGOHL-UHFFFAOYSA-N

Comparar elementos similares

Ver comparación completa

Mostrar Diferencias

1 of 4

Este artículo
348848348791460400
form

foil

form

foil

form

foil

form

wire

assay

99.7% trace metals basis

assay

99.98% trace metals basis

assay

99.7% trace metals basis

assay

99.7% trace metals basis

density

4.5 g/mL at 25 °C (lit.)

density

4.5 g/mL at 25 °C (lit.)

density

4.5 g/mL at 25 °C (lit.)

density

4.5 g/mL at 25 °C (lit.)

resistivity

42.0 μΩ-cm, 20°C

resistivity

42.0 μΩ-cm, 20°C

resistivity

42.0 μΩ-cm, 20°C

resistivity

42.0 μΩ-cm, 20°C

bp

3287 °C (lit.)

bp

3287 °C (lit.)

bp

3287 °C (lit.)

bp

3287 °C (lit.)

mp

1660 °C (lit.)

mp

1660 °C (lit.)

mp

1660 °C (lit.)

mp

1660 °C (lit.)

General description

Titanium is a highlycorrosion-resistant metal that finds application in the fields ofelectrochemical catalysis, aerospace engineering, and biomedical implants. Ithas excellent strength, biocompatibility, Young’s modulus, and low density.

Application

Titanium is extensively used as a substrate to grow titanium oxidenanotubes via anodization process. For example, it can be used to fabricate TiO2thin films and hydroxyapatite/Gr bioactive coatings.

Preparation Note

150 × 150 mm (approximately 25.2 g)

Clase de almacenamiento

13 - Non Combustible Solids

wgk_germany

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable

ppe

Eyeshields, Gloves, type N95 (US)


Elija entre una de las versiones más recientes:

Certificados de análisis (COA)

Lot/Batch Number

¿No ve la versión correcta?

Si necesita una versión concreta, puede buscar un certificado específico por el número de lote.

¿Ya tiene este producto?

Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.

Visite la Librería de documentos

A Kurbad et al.
International journal of computerized dentistry, 16(2), 125-141 (2013-08-13)
This article presents two novel options for lithium-disilicate restorations supported by single-tooth implants. By using a Ti-Base connector, hybrid abutments and hybrid abutment crowns can be fabricated for different implant systems. The latter option in particular is an interesting new
Jinho Shin et al.
Journal of nanoscience and nanotechnology, 13(8), 5807-5810 (2013-07-26)
In this study, hydroxyapatite (HA) was coated on anodized titanium (Ti) surfaces through radio frequency magnetron sputtering in order to improve biological response of the titanium surface. All the samples were blasted with resorbable blasting media (RBM). RBM-blasted Ti surface
Kwi-Dug Yun et al.
Journal of nanoscience and nanotechnology, 13(6), 3864-3867 (2013-07-19)
This study examined the bone response to titanium dioxide nanotube modified implants. A total of 24 implants were placed in the femur of 4 beagles. Before placement, screw-shaped implants were classified into 3 groups; machined surface (group M), titanium dioxide
D M Rivera-Chacon et al.
Journal of biomedical nanotechnology, 9(6), 1092-1097 (2013-07-19)
Improvements in osteoconduction of implant biomaterials require focusing on the bone-implant interface, which is a complex multifactorial system. Surface topography of implants plays a crucial role at this interface. Nanostructured surfaces have been shown to promote serum protein adsorption and
Study of a TiO2 photocatalytic coating for use in plasma catalysis.
K Van Wesenbeeck et al.
Communications in agricultural and applied biological sciences, 78(1), 227-233 (2013-07-24)

Artículos

Biomedical implants are essentially foreign substances within the human body that must survive many years’ exposure to demanding mechanical and physiological conditions. Despite these challenges, metal implants have been widely used to substitute for or rebuild hard tissues such as bones and teeth.

Questions

1–2 of 2 Questions  
  1. Bonjour, les feuilles de titane (épaisseur 0,25 mm) ont quelles dimensions (largeur et longueur)? cdlt, Tommaso

    1 answer
    1. The dimensions are 150 × 150 mm.

      Helpful?

  2. Dimensions of sample (width x height) ?

    1 answer
    1. The dimensions of this item are 150 × 150 mm with a thickness of 0.25 mm.

      Helpful?

Reviews

Active Filters

  1. 1 Ratings-only review

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico