Merck

57439-U

Supelco

SPME-OC Fiber Assembly, Polydimethylsiloxane/Divinylbenzene (PDMS/DVB)

df 75 μm(Coating thickness includes 65 μm coating + 10 μm OC (overcoating), needle size 23 ga, pkg of 3 ea, fiber L 1 cm

Sinónimos:
SPME-Overcoated Fiber Polydimethylsiloxane/Divinylbenzene (PDMS/DVB)
NACRES:
NB.21

material

StableFlex fiber (Polydimethylsiloxane/Divinylbenzene (PDMS/DVB))
notched pink hub

Nivel de calidad

tamaño de la aguja

23 ga

descripción

Polydimethylsiloxane/Divinylbenzene (PDMS/DVB) fiber overcoated with a layer of PDMS.

envase

pkg of 3 ea

df

75 μm (Coating thickness includes 65 μm coating + 10 μm OC (overcoating))

technique(s)

solid phase microextraction (SPME): suitable

fibra Al

1 cm

grupo activo de la matriz

PDMS/DVB coating, Overcoated Polydimethylsiloxane/Divinylbenzene

application(s)

food and beverages

compatibilidad

for use with autosampler or manual (for direct immersion into matrix or headspace analysis of volatile or semi-volatile analytes (MW 50-300+))

Categorías relacionadas

Comparar elementos similares

Ver comparación completa

Show Differences

1 of 4

Este artículo
57345-U57327-U57326-U
df

75 μm (Coating thickness includes 65 μm coating + 10 μm OC (overcoating))

df

65 μm (PDMS/DVB)

df

65 μm (PDMS/DVB)

df

65 μm (PDMS/DVB)

matrix active group

PDMS/DVB coating, Overcoated Polydimethylsiloxane/Divinylbenzene

matrix active group

PDMS/DVB coating

matrix active group

PDMS/DVB coating

matrix active group

PDMS/DVB coating

compatibility

for use with autosampler or manual (for direct immersion into matrix or headspace analysis of volatile or semi-volatile analytes (MW 50-300+))

compatibility

for analyte group volatiles, amines, and nitroaromatic compounds (MW 50-300), for use with autosampler

compatibility

for analyte group volatiles, amines, and nitroaromatic compounds (MW 50-300), for use with autosampler

compatibility

for analyte group volatiles, amines, and nitroaromatic compounds (MW 50-300), for use with manual holder

needle size

23 ga

needle size

23 ga

needle size

24 ga

needle size

24 ga

description

Polydimethylsiloxane/Divinylbenzene (PDMS/DVB) fiber overcoated with a layer of PDMS.

description

-

description

-

description

-

Descripción general

A new development in SPME fiber technology incorporates a protective overcoating on the fiber. This overcoating, which consists of polydimethylsiloxane (PDMS) serves as a barrier to protect the fiber from the matrix, which makes it more physically robust and less prone to chemical fouling. High background samples, such as many foods, pose a challenge to immersion SPME due to the presence of fats, sugars, pigments, and other macromolecules. These can stick to the SPME fiber and reduce its usable life and/or be transferred to the GC, where they may interfere with chromatographic analysis. Overcoating the fiber with PDMS reduces these problems.

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Las referencias de los producto se combinan con los tamaños de envase y las cantidades cuando se muestran en la página web, por ejemplo: T1503-25G. Asegúrese de introducir el número de producto ÚNICAMENTE en el campo del Número de producto (Ejemplo T1503).

Ejemplo

T1503
Referencia del producto
-
25G
Tamaño del envase/cantidad

Otros ejemplos

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

introducir como1.000309185)

¿Tiene algún problema? No dude en ponerse en contacto con nosotros Servicio técnico para asistencia

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Productos Aldrich

  • Si encuentra un número de lote como TO09019TO, introduzca el número de lote 09019TO sin las dos primeras letras.

  • Si encuentra un número de lote con un código de entrada como 05427ES-021, introduzca el número 05427ES sin el código de entrada -021.

  • Si encuentra un número de lote con un código de entrada como STBB0728K9, introduzca el código de lote STBB0728 sin el código de entrada K9.

¿No ha encontrado lo que estaba buscando?

En algunos casos, puede que un COA no esté disponible en la página web. Si su búsqueda no encontró el COA puede solicitarlo.

Solicitar COA

Jermiah Y Shen et al.
Journal of separation science, 35(19), 2544-2552 (2012-08-22)
The presence of triclosan and triclocarban, two endocrine-disrupting chemicals and antimicrobial agents, and transformation products of triclocarban, 1,3-di(phenyl)urea, 1,3-bis(4-chlorophenyl)urea and 1,3-bis(3,4-dichlorophenyl)urea, in tap water, treated household drinking water, bottled water, and river water samples were investigated using solid-phase micro-extraction coupled
A P Arisseto et al.
Food additives & contaminants. Part A, Chemistry, analysis, control, exposure & risk assessment, 29(12), 1832-1839 (2012-08-23)
Selected commercial processed foods available in the Brazilian market (306 samples) were analysed for furan content using a validated gas chromatography-mass spectrometry method preceded by headspace solid phase micro-extraction (HS-SPME-GC/MS). Canned and jarred foods, including vegetable, meat, fruit and sweet
Alfredo Koch et al.
Phytochemistry, 71(17-18), 2190-2198 (2010-10-23)
2-Methoxy-3-isobutylpyrazine (MIBP) contributes a bell pepper aroma to many grape cultivars and has a reported aroma threshold of ∼2 ng L(-1) in water. The purpose of this study was twofold: (1) develop a procedure using headspace solid phase micro-extraction combined
J H Han et al.
Journal of food science, 73(8), E349-E355 (2008-11-21)
Physical properties of whey protein isolate (WPI) coating solution incorporating ascorbic palmitate (AP) and alpha-tocopherol (tocopherol) were characterized, and the antioxidant activity of dried WPI coatings against lipid oxidation in roasted peanuts were investigated. The AP and tocopherol were mixed
Cristina Sala et al.
Journal of agricultural and food chemistry, 52(11), 3492-3497 (2004-05-27)
The influence of vine training and sunlight exposure on the 3-alkyl-2-methoxypyrazines contents in musts and wines was studied by means of two previously reported methods based on headspace solid-phase micro-extraction. Experimental samples were monitored throughout grape ripening and wine making.

Artículos

Analysis of Pesticides in Baby Food by Solid Phase Microextraction (SPME) Using a New Overcoated Fiber

A direct immersion SPME method using a new overcoated SPME fiber was developed for the extraction of pesticides from pureed prune baby food.

GC/MS/MS Analysis of Bisphenol A (BPA) in a Fruit Flavored Energy Drink on the SLB-PAHms Column After SPME Using an Overcoated SPME Fiber

Bisphenol A (BPA) plastic is controversial in food and beverage containers. This study demonstrates SPME of BPA from an energy drink using an overcoated PDMS/DVB fiber, followed by GC/MS/MS analysis using SLB-PAHms GC Column.

Protocolos

Analysis of Bisphenol A in Food by Solid Phase Microextraction Using an Overcoated Fiber

Bisphenol A (BPA) is suspected to be an endocrine disruptor. Regulations on specific migration limits (SML) from food contact materials are getting tighter (EU 2018/213) requiring more sensitive determinations. An overcoated SPME fiber provides the durability necessary for direct immersion into foods such as canned soup and pumpkin, allowing for low level analysis of BPA via SPME-GC-MS/MS.

Contenido relacionado

Solid Phase Microextraction (SPME)

Solid phase microextraction (SPME) is a solvent-free sample preparation technique that uses coated fibers to extract analytes of interest from a sample before analysis by GC or HPLC.

Microextracción en fase sólida (SPME)

La microextracción en fase sólida (SPME) es una técnica de preparación de muestras sin disolvente en la que se utilizan fibras recubiertas para extraer analitos de interés de una muestra antes del análisis mediante GC o HPLC.

Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.

Póngase en contacto con el Servicio técnico