• Inicio
  • Resultados de la búsqueda
  • A multiclass method for the analysis of endocrine disrupting chemicals in human urine samples. Sample treatment by dispersive liquid-liquid microextraction.

A multiclass method for the analysis of endocrine disrupting chemicals in human urine samples. Sample treatment by dispersive liquid-liquid microextraction.

Talanta (2014-08-17)
F Vela-Soria, O Ballesteros, A Zafra-Gómez, L Ballesteros, A Navalón
RESUMEN

The population is continuously exposed to endocrine disrupting chemicals (EDCs). This has influenced an increase in diseases and syndromes that are more frequent nowadays. Therefore, it is necessary to develop new analytical procedures to evaluate the exposure with the ultimate objective of establishing, in an accurate way, relationships between EDCs and harmful health effects. In the present work, a new method based on a sample treatment by dispersive liquid-liquid microextraction (DLLME) for the extraction of six parabens (methyl-, ethyl-, isopropyl-, propyl-, isobutyl and butylparaben), six benzophenones (benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-6, benzophenone-8 and 4-hydroxybenzophenone) and two bisphenols (bisphenol A and bisphenol S) in human urine samples, followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) analysis is proposed. An enzymatic treatment allows determining the total content of the target EDCs. The extraction parameters were accurately optimized using multivariate optimization strategies. Ethylparaben ring-(13)C6 and bisphenol A-d16 were used as surrogates. Found limits of quantification ranging from 0.2 to 0.5 ng mL(-1) and inter-day variability (evaluated as relative standard deviation) ranging from 2.0% to 14.9%. The method was validated using matrix-matched standard calibration followed by a recovery assay with spiked samples. Recovery rates ranged from 94% to 105%. A good linearity, for concentrations up to 300 ng mL(-1) for parabens and 40 ng mL(-1) for benzophenones and bisphenols, respectively, was obtained. The method was satisfactorily applied for the determination of target compounds in human urine samples from 20 randomly selected individuals.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, anhydrous, ≥99.5%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, for molecular biology
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, meets USP testing specifications
Sigma-Aldrich
Ethyl alcohol, Pure, 190 proof, ACS spectrophotometric grade, 95.0%
Sigma-Aldrich
Ethanol, anhydrous, denatured
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Ethanol, BioUltra, for molecular biology, ≥99.8%, (absolute alcohol, without additive, A15 o1)
Supelco
Ethanol, standard for GC
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Supelco
Methanol, analytical standard
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ethyl acetate, ACS reagent, ≥99.5%
Sigma-Aldrich
Citric acid, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethyl acetate, suitable for HPLC, ≥99.7%
Sigma-Aldrich
Ethyl alcohol, Pure, 200 proof, ACS reagent, ≥99.5%
Sigma-Aldrich
Ethyl acetate, anhydrous, 99.8%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Sigma-Aldrich
Potassium chloride, ACS reagent, 99.0-100.5%
Sigma-Aldrich
Sodium sulfate, ACS reagent, ≥99.0%, anhydrous, granular
Sigma-Aldrich
Magnesium sulfate, anhydrous, ReagentPlus®, ≥99.5%
Sigma-Aldrich
Sodium phosphate monobasic, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Chlorobenzene, anhydrous, 99.8%
Sigma-Aldrich
Sodium sulfate, ACS reagent, ≥99.0%, anhydrous, powder
Sigma-Aldrich
Potassium chloride, for molecular biology, ≥99.0%