• Inicio
  • Resultados de la búsqueda
  • Simultaneous determination of perfluorinated compounds and their potential precursors in mussel tissue and fish muscle tissue and liver samples by liquid chromatography-electrospray-tandem mass spectrometry.

Simultaneous determination of perfluorinated compounds and their potential precursors in mussel tissue and fish muscle tissue and liver samples by liquid chromatography-electrospray-tandem mass spectrometry.

Journal of chromatography. A (2015-02-25)
I Zabaleta, E Bizkarguenaga, A Prieto, M Ortiz-Zarragoitia, L A Fernández, O Zuloaga
RESUMEN

An analytical method for the simultaneous determination in fish liver and muscle tissue and mussel samples of 14 perfluorinated compounds (PFCs), including three perfluoroalkylsulfonates (PFSAs), seven perfluorocarboxylic acids (PFCAs), three perfluorophosphonic acids (PFPAs) and perfluorooctanesulfonamide (PFOSA), and 10 potential precursors, including four polyfluoroalkyl phosphates (PAPs), four fluorotelomer saturated acids (FTCAs) and two fluorotelomer unsaturated acids (FTUCAs), was developed in the present work. Different clean-up strategies by means of solid-phase extraction (SPE) using a mix-mode weak anion exchanger (WAX), reverse phase Envi-Carb or a combination of them was optimized and evaluated for the clean-up of focused ultrasonic solid-liquid (FUSLE) extracts before the analysis by liquid chromatography-triple quadrupole tandem mass spectrometry (LC-MS/MS). Mix-mode WAX coupled in-line to Envi-Carb was finally selected since it rendered the cleanest extracts and minimum matrix effect. The FUSLE-SPE-LC-MS/MS methodology was validated in terms of recovery, precision and method detection limits (MDLs). Apparent recovery values in the 65-116%, 59-119% and 67-126% range and MDLs in the 0.1-2.7 ng/g, 0.1-3.8 ng/g and 0.2-3.1ng/g range were obtained for liver, mussel and fish muscle tissue samples, respectively. The method developed was applied to the analysis of grey mullet liver (Chelon labrosus) and mussel (Mytilus galloprovincialis) samples from the Basque Coast (North of Spain) and Yellowfin tuna muscle tissue (Thunnus albacares) samples from the Indian Ocean. To the best of our knowledge this is the first method that describes the simultaneous determination of 14 PFCs and 10 potential precursors in fish liver, fish muscle tissue and mussel samples. Besides, this is the first time that 8:2 monosubstituted polyfluorodecyl phosphate (8:2 monoPAP) and 8:2 disubstituted polyfluorodecyl phosphate (8:2 diPAP) were detected in mussel and tuna samples, respectively.

MATERIALES
Referencia del producto
Marca
Descripción del producto

Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Acetic acid, glacial, ReagentPlus®, ≥99%
Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Supelco
Methanol, analytical standard
Sigma-Aldrich
Ammonium hydroxide solution, ACS reagent, 28.0-30.0% NH3 basis
Sigma-Aldrich
Acetic acid, glacial, ACS reagent, ≥99.7%
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Methanol, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8% (GC)
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Methanol, ACS reagent, ≥99.8%
Supelco
Ammonium acetate, suitable for mass spectrometry (MS), LiChropur, eluent additive for LC-MS
Sigma-Aldrich
tert-Butyl methyl ether, anhydrous, 99.8%
Sigma-Aldrich
Ammonium hydroxide solution, 28% NH3 in H2O, ≥99.99% trace metals basis
Sigma-Aldrich
Acetic acid, glacial, puriss., meets analytical specification of Ph. Eur., BP, USP, FCC, 99.8-100.5%
Sigma-Aldrich
Ammonium acetate, for molecular biology, ≥98%
Sigma-Aldrich
Formic acid, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥98%
Sigma-Aldrich
Acetic acid, glacial, puriss. p.a., ACS reagent, reag. ISO, reag. Ph. Eur., ≥99.8%
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
tert-Butyl methyl ether, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Formic acid, puriss., meets analytical specifications of DAC, FCC, 98.0-100%
Sigma-Aldrich
Divinylbenzene, technical grade, 80%
Sigma-Aldrich
Ammonium acetate, ACS reagent, ≥97%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Supelco
Acetic acid, analytical standard