If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf
Select a Size
About This Item
Skip To
material
polypropylene tube
technique(s)
solid phase extraction (SPE): suitable
application(s)
environmental
food and beverages
Quality Level
Looking for similar products? Visit Product Comparison Guide
1 of 4
This Item | 57265 | 57030-U | 57250-U |
|---|---|---|---|
| technique(s) solid phase extraction (SPE): suitable | technique(s) solid phase extraction (SPE): suitable | technique(s) solid phase extraction (SPE): suitable | technique(s) solid phase extraction (SPE): suitable |
| application(s) environmental | application(s) food and beverages | application(s) environmental | application(s) environmental |
| material polypropylene tube | material PTFE frit, polypropylene tube | material UHMW PE frit, polypropylene tube | material UHMW PE frit, polypropylene tube |
| Quality Level 100 | Quality Level 100 | Quality Level 100 | Quality Level 100 |
Features and Benefits
- Patented screw-type valves within each SPE port for precise flow control
- Glass basin will not dissolve, fog, or discolor when exposed to solvents
- Legs on cover allow user to easily rest cover on work surface when removed from the manifold
- Screw-type solvent-resistant vacuum bleed gauge and valve offer better sealing and vacuum control. Valve takes 1/4″ vacuum tubing.
- PP collection vessel rack accommodates autosampler vials; small scintillation vials (22.75 mm O.D. recommended); 10 and 16 mm test tubes; and 1, 2, 5, and 10 mL volumetric flasks. An optional plate for 20 mL scintillation vials is available for 12-port models.
General description
Legal Information
related product
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
2-layer SPE cartridge efficiently reduces background for ginger contaminant analysis.
Use QuEChERS methods to analyze samples of milk for veterinary drugs.
Analysis of 20 pharmaceutical compounds in calf serum using Supel™ Swift HLB SPE cartridge for cleanup and LC-MS determination and another commercially available HLB cartridge for comparison.
Dual-layer cartridge achieves efficient SPE clean-up for challenging pesticide residue testing in turmeric and spices.
Protocols
Optimize β-glucuronidase hydrolysis for glucuronide metabolite analysis considering factors like time, temperature, pH, and enzyme concentration.
Paprika spice's PAH contamination risk due to environmental exposure highlights food safety concerns.
solution, 2 μg/mL in acetonitrile, analytical standard
Related Content
Solid phase extraction purifies samples for chromatographic analysis, improving data quality and protecting analytical columns.
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
Helpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-
-
What is the spacing between ports for the manifolds?
1 answer-
Visiprep 12 Port, Product Dimensions
1 1/8" (1.14") Between valves (center to center)
1 5/8" Between rows (center to center)
All ports on the 12 and 24 vacuum manifolds can only be used simultaneously with 1, 3, and 6mL tubes. In order to use all ports of the manifold with 12, 20, or 60 mL SPE tubes, Long Stem Flow Control Valves are required – see product 57048.Helpful?
-
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service


