Skip to Content
Merck
  • Quantitative LC-MS/MS determination of flupirtine, its N-acetylated and two mercapturic acid derivatives in man.

Quantitative LC-MS/MS determination of flupirtine, its N-acetylated and two mercapturic acid derivatives in man.

Journal of pharmaceutical and biomedical analysis (2014-12-03)
Eberhard Scheuch, Karen Methling, Patrick J Bednarski, Stefan Oswald, Werner Siegmund
ABSTRACT

The non-opiate analgesic drug flupirtine was shown in vitro to undergo hydrolysis followed by N-acetylation to form D13223, glucuronidation and conjugation with glutathione to form the stable mercapturic acid derivatives M-424 and M-466. To quantify flupirtine and its metabolites in samples obtained in a clinical study in healthy subjects selected on their genotype of NAT2, UGT1A1 and GSTP1, two LC-MS/MS methods were developed. The validation range for flupirtine and D-13223 in serum was 0.5-500 ng/ml. For urine and feces, the validation ranges for flupirtine and D-13223 were 20-5000 ng/ml and 5.0-5000 ng/ml, respectively. M-424 and M-466 could be quantified in urine between 5.0 and 5000 ng/ml. Free flupirtine and D-13223 were separated from serum, urine and feces with liquid-liquid extraction. For flupirtine and D-13223, the chromatography was performed on a XTerra C18 column isocratically with a mobile phase consisting of ammonium formate buffer (pH 3.5mM) and acetonitrile (50:50; v/v), for M-466 and M-424 a Synergi(®) Fusion-RP column was used and a linear gradient method with water/HCOOH (pH 3) and acetonitrile. The mass spectrometer operated both with electro spray ionization in positive multiple reaction monitoring mode. The developed methods fulfilled the current FDA criteria on bioanalytical method validation for accuracy (error: -16.9 to 11.2%), precision (1.2-13.4%), recovery, stability and matrix effects over the observed analytical range. Thus, the methods were suitable to quantify flupirtine absorption and metabolic disposition in man after single intravenous and oral dosing (100mg) and repeated oral administration (400mg once daily).

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Acetonitrile, anhydrous, 99.8%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Acetonitrile, ReagentPlus®, 99%
Sigma-Aldrich
Acetonitrile, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetonitrile, suitable for HPLC, gradient grade, ≥99.9%
USP
Residual Solvent Class 2 - Acetonitrile, United States Pharmacopeia (USP) Reference Standard
Supelco
Acetonitrile, analytical standard
Sigma-Aldrich
Acetonitrile, biotech. grade, ≥99.93%
Sigma-Aldrich
Acetonitrile, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrile, HPLC Plus, ≥99.9%
Sigma-Aldrich
Ammonium formate solution, BioUltra, 10 M in H2O
Sigma-Aldrich
Formic acid, reagent grade, ≥95%
Sigma-Aldrich
Formic acid solution, BioUltra, 1.0 M in H2O
Sigma-Aldrich
Formic acid, ACS reagent, ≥96%
Sigma-Aldrich
Formic acid, ACS reagent, ≥88%
USP
Methyl alcohol, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetonitrile, suitable for DNA synthesis, ≥99.9% (GC)
Sigma-Aldrich
Formic acid, ≥95%, FCC, FG
Supelco
Sulfadimethoxine, Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Supelco
Sulfadimethoxine, VETRANAL®, analytical standard
Supelco
Sulfadimethoxine, 98.0-102.0%
Sigma-Aldrich
Ammonium formate, BioUltra, ≥99.0% (calc. based on dry substance, NT)
Supelco
Ammonium formate, eluent additive for LC-MS, LiChropur, ≥99.0%
Sigma-Aldrich
Ammonium formate, reagent grade, 97%
Sigma-Aldrich
Ammonium formate, ≥99.995% trace metals basis
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Methanol, analytical standard
Sigma-Aldrich
Methanol, Absolute - Acetone free