Przejdź do zawartości
Merck

Analiza LC/MS/MS pozostałości pestycydów w daktylach na kolumnie Ascentis® Express RP-Amide po ekstrakcji QuEChERS

Analiza LC/MS/MS pozostałości pestycydów w daktylach na kolumnie Ascentis® Express RP-Amide po ekstrakcji QuEChERS application for LC-MS, application for SPE

Materiały

produkt powiązany

Numer produktu
Opis
Cennik

Quinalphos

PESTANAL®, analytical standard

Rotenone

PESTANAL®, analytical standard

Aldicarb-sulfone

PESTANAL®, analytical standard

Etrimfos

PESTANAL®, analytical standard

Neburon

PESTANAL®, analytical standard

Omethoate

PESTANAL®, analytical standard

Butocarboximsulfoxide

PESTANAL®, analytical standard

Ethylene oxide solution

certified reference material, 50 mg/mL in methanol

Supel QuE

Citrate Extraction Tube, pk of 50, suitable for EN 15662

Spiromesifen

PESTANAL®, analytical standard

Supel QuE

Empty Centrifuge Tube with Lid, centrifuge tube volume 50 mL, pk of 50, suitable for EN 15662:2008 per BS

Malathion

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Supel QuE

PSA/C18 Tube, pack of 100, AOAC® 2007.01

Carbendazim

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Supel QuE

PSA Tube, pk of 50, AOAC® 2007.01, centrifuge tube volume 15 mL , Shaker Compatible

Aldicarb

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Ascentis® Express RP-Amide, 2 μm UHPLC Column

2 μm particle size, L × I.D. 10 cm × 2.1 mm

Methomyl

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Thiacloprid

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Carbofuran

reference material

Bifenazate

reference material

Chlorantraniliprole

reference material

Methabenzthiazuron

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Triazophos

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Trichlorfon

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Spinetoram solution

100 μg/mL in acetonitrile, certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Pyraflufen-ethyl

certified reference material, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

used together

Numer produktu
Opis
Cennik

Glufosinate-ammonium

PESTANAL®, analytical standard

wyposażenie dodatkowe

Numer produktu
Opis
Cennik

Certified Vial Kit, Low Adsorption (LA), 2 mL, pk of 100

volume 2 mL, amber glass vial (with marking spot), natural PTFE/silicone septa (with slit), thread for 9 mm

Benchmixer XL multi-tube vortexer

AC/DC input 115 V AC

CONDITIONS

sample/matrix

5 g ground dates spiked with pesticides at 10 ng/g

extraction process

add 10 mL water and 10 mL acetonitrile; shake 1 hr at 2500 rpm; add contents of Supel QuE citrate extraction tube (55227-U); . (shake for 1 minute; centrifuge at 5000 rpm fo 5 minutes and draw off supernatant)

clean-up tube

Supel QuE PSA/C18 (55288-U)

clean-up process

transfer 1 mL of the extract to 2 mLSupel QuE PSA/C18 tube; shake for 1 minute; centrifuge at 5000 rpm for 3 min; draw off supernatant for analysis.

sample preparation

Dilute 100 μL of cleaned extract to a final volume of 1 mL in 5 mM ammonium formate/0.1% formic acid in water; transfer diluted sample to vial for LC/MS/MS analysis

column

Ascentis Express RP-Amide, 10 cm x 2.1 mm I.D., 2 μm particles (51576-U)

mobile phase

(A) 5 mM ammonium formate with 0.1% formic acid in water; (B) 5 mM ammonium formate with 0.1% formic acid in 95:5 acetonitrile:H2O

gradient

held at 5% B from 0 to 1 min; to 100% B in 13 min; held at 100% B for 1.5 min; to 95% A in 0.5 min; held at 95% A for 1.5 min

flow rate

0.4 mL/min

column temp.

30 °C

detector

MS, ESI (+), MRM

injection

5 μL

Opis

Zastosowanie

Zamrozić daktyle ciekłym azotem i zmielić na jednolitą masę.

Komentarz do analizy

Metoda "szybka, łatwa, tania, skuteczna, wytrzymała i bezpieczna" (QuEChERS) może być stosowana do analizy wielu pozostałości pestycydów występujących w daktylach. W tym badaniu do analizy pozostałości pestycydów w pistacjach wykorzystano ekstrakcję QuEChERS i oczyszczanie przy użyciu PSA/C18. Średnie odzyski uzyskane dla powtarzalnych próbek z domieszką 10 ng/g mieściły się w zakresie 70-120% dla 23 z 25 analizowanych pestycydów.

Informacje prawne

Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany