Skip to Content
Merck

Skip To

NA0310

GenElute HP Plasmid Maxiprep Kit

greener alternative

sufficient for 25 purifications

Synonym(s):

GenElute HP Plasmid Maxiprep Kit, plasmid extraction kit, plasmid isolation kit, plasmid purification kit

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice

About This Item

NACRES:
NA.52
UNSPSC Code:
41105501
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


usage

sufficient for 25 purifications

Quality Level

greener alternative product characteristics

Designing Safer Chemicals
Learn more about the Principles of Green Chemistry.

sustainability

Greener Alternative Product

technique(s)

DNA purification: suitable

test parameters

sample volume: 150 mL bacterial culture

greener alternative category

storage temp.

15-25°C

General description

The GenElute HP Plasmid Maxiprep Kit offers a simple, rapid, and cost effective method for isolating plasmid DNA from recombinant E. coli cultures. The kit features a filter syringe for the rapid clearing of lysate and a silica binding column designed for either a vacuum or a spin format. Up to 1.2 mg of plasmid DNA can be isolated from a 150 mL overnight culture grown in Luria Broth (LB) medium. Note that the actual yield depends on the strain, the plasmid, and the culture medium used.

An overnight recombinant E. coli culture is harvested by centrifugation and subjected to a modified alkaline-SDS lysis procedure followed by adsorption of the DNA onto a silica membrane in the presence of high salts. Contaminants are removed by two wash steps. Finally, the bound DNA is eluted in Elution Solution (Tris-HCl) or water.

The recovered plasmid DNA is predominately in its supercoiled form. The DNA is ready for immediate use in downstream applications such as restriction digestion, ligation, sequencing, PCR, transformation, and transfection.
We are committed to bringing you Greener Alternative Products, which adhere to one or more of The 12 Principles of Greener Chemistry. This product has Inherently Safer Chemistry, compared to the standard use of phenol and chloroform to perform DNA extractions.

Application

GenElute HP Plasmid Maxiprep Kit has been used in the isolation of plasmids.

Features and Benefits

  • From harvested bacterial culture to pure plasmid DNA in 30 minutes or less
  • Up to 1.2 mg of high-copy plasmid DNA
  • Flexibility of a vacuum or spin format
  • Contains fewer plastic components than other high speed kits, reducing the amount of waste
  • No phenol/chloroform extraction or alcohol precipitation required

Other Notes

For additional information, please see www.sigma-aldrich.com/genelutehp.

Legal Information

GenElute is a trademark of Sigma-Aldrich Co. LLC

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
NA0300PLEX15PLX15
usage

sufficient for 25 purifications

usage

sufficient for 10 purifications

usage

sufficient for 15 purifications

usage

sufficient for 15 purifications

technique(s)

DNA purification: suitable

technique(s)

DNA purification: suitable

technique(s)

DNA purification: suitable

technique(s)

DNA purification: suitable

test parameters

sample volume: 150 mL bacterial culture

test parameters

sample volume: 50 mL bacterial culture

test parameters

: <2 hr kit run time for up to 12 preps, sample volume: 25-200 mL bacterial culture

test parameters

: ~45 min kit run time, sample volume: 25-200 mL bacterial culture

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

greener alternative category

Aligned,

greener alternative category

Aligned,

greener alternative category

, Aligned

greener alternative category

Aligned,

greener alternative product characteristics

Designing Safer Chemicals
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Designing Safer Chemicals
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Inherently Safer Chemistry for Accident Prevention
Learn more about the Principles of Green Chemistry.

greener alternative product characteristics

Designing Safer Chemicals
Learn more about the Principles of Green Chemistry.


Still not finding the right product?


Kit Components Also Available Separately

Product No.
Description
SDS & Pricing

  • Column Preparation Solution 2
    SDS

  • Lysis Solution
    SDS

  • Resuspension Solution, Add RNase A before use. After addition of RNAse, store at 2-8ºC. )
    SDS

  • RNase A solution
    SDS

  • Wash Solution 1
    SDS

  • Wash Solution 2
    SDS

signalword

Danger

target_organs

Central nervous system

Storage Class

3 - Flammable liquids

flash_point_f

77.0 °F - closed cup

flash_point_c

25 °C - closed cup

wgk

WGK 3

Hazard Classifications

Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Dam. 1 - Flam. Liq. 3 - Met. Corr. 1 - Resp. Sens. 1 - Skin Corr. 1B - STOT SE 3



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

Don't see the Right Version?

If you require a particular version, you can look up a specific certificate by the Lot or Batch number.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Protocols

Follow this simple, rapid, and cost-effective method for isolating plasmid DNA from recombinant E. coli cultures with the GenElute™ HP Plasmid Maxiprep kit.


Fraser Soares et al.
Blood, 137(16), 2171-2181 (2020-12-04)
Acute myeloid leukemia (AML) remains a devastating disease in need of new therapies to improve patient survival. Targeted adoptive T-cell therapies have achieved impressive clinical outcomes in some B-cell leukemias and lymphomas but not in AML. Double-negative T cells (DNTs)
Musaddeque Ahmed et al.
Nature communications, 12(1), 1781-1781 (2021-03-21)
Prostate cancer (PCa) risk-associated SNPs are enriched in noncoding cis-regulatory elements (rCREs), yet their modi operandi and clinical impact remain elusive. Here, we perform CRISPRi screens of 260 rCREs in PCa cell lines. We find that rCREs harboring high risk
Jaeho Yoon et al.
Biomedicines, 9(9) (2021-09-29)
Renal hypouricemia is a rare genetic disorder. Hypouricemia can present as renal stones or exercise-induced acute renal failure, but most cases are asymptomatic. Our previous study showed that two recessive variants of SLC22A12 (p.Trp258*, pArg90His) were identified in 90% of



Global Trade Item Number

SKUGTIN
NA0310-1KT04061834119036

Questions

1–6 of 6 Questions  
  1. Is plasmid DNA isolated with this kit suitable for use in transfection?

    1 answer
    1. Yes. However, if you are currently required to use an endofree plasmid purification kit, we recommend using the GenElute HP Endotoxin-free Kit.

      Helpful?

  2. Which format gives a better yield, vacuum or spin?

    1 answer
    1. There is no difference in plasmid recovery when using either format.

      Helpful?

  3. How long does it take to isolate plasmid using the vacuum format?

    1 answer
    1. A midiprep or maxiprep requires only 30 minutes to complete.

      Helpful?

  4. How do the GenElute HP Plasmid Kits differ from other plasmid purification systems?

    1 answer
    1. The GenElute HP Plasmid Kits are much faster than other commercially available kits. A filter syringe is used for preparing the cleared lysate, which replaces a lengthy centrifugation step. These kits also offer the option of using a vacuum or spin purification format rather than a gravity drip to bind, wash and elute the plasmid. In addition, samples are eluted in Tris buffer so there are no alcohol precipitations required.

      Helpful?

  5. What is the expected yield of plasmid DNA that you can isolate from these kits?

    1 answer
    1. Yields can reach as high as 350 mg for a midiprep and 1.2 mg for a maxiprep. As with any protocol, lower yields can be expected with low copy plasmids.

      Helpful?

  6. Do the binding columns fit on other manufacturers’ manifolds?

    1 answer
    1. Yes. The columns fit on all standard vacuum manifolds.

      Helpful?

Reviews

No rating value

Active Filters