This product is provided as a volumetric solution for titration. The concentration is reported on the lot-specific certificate of analysis without formal analysis of purity or trace metals. Please consider an alternate grade of hydrochloric acid such as 339253, HX0607, or 1.15186. These products are evaluated for metal content with reported purity and are more suitable for trace metal analysis.
Select a Size
| Pack Size | SKU | Availability | Price |
|---|
About This Item
Product Name
Hydrochloric acid solution, c(HCl) = 1 mol/l (1 N), Titripur®, reag. Ph. Eur., reag. USP
Quality Level
agency
reag. Ph. Eur., reag. USP
product line
Titripur®
form
liquid
quality
Analyzed in our ISO 17025 accredited QC lab
reaction suitability
reaction type: Acid-base reactions
packaging
Titripac® of
concentration
1 M
technique(s)
titration: suitable
pH
<1 (20 °C in H2O)
density
1.02 g/cm3 at 20 °C
storage temp.
15-25°C
SMILES string
Cl
InChI
1S/ClH/h1H
InChI key
VEXZGXHMUGYJMC-UHFFFAOYSA-N
Application
- Research on the Synthesis of Zinc-Ammonium Phosphate Using Galvanic Waste Sludge as a Source of Zinc.: This study explores the synthesis of zinc-ammonium phosphate from galvanic waste sludge. Hydrochloric acid solution is utilized in the extraction process, demonstrating its effectiveness in recovering valuable metals from industrial waste (Morgovan et al., 2024).
- Corrosion inhibition of mild steel in hydrochloric acid solution by the expired Ampicillin drug.: This research investigates the use of expired Ampicillin as a corrosion inhibitor for mild steel in hydrochloric acid solutions. The study highlights a novel application for expired pharmaceuticals in mitigating corrosion in acidic environments (Alamry et al., 2023).
- Contactless conductivity sensor employing moist paper as absorbent for in-situ detection of generated carbon dioxide gas.: This paper discusses a contactless conductivity sensor for detecting CO2 gas, utilizing hydrochloric acid solutions to generate the gas for calibration and testing. The method offers a simple and efficient approach for environmental monitoring (Sonsa-Ard et al., 2020).
- The microwave induced plasma with optical emission spectrometry (MIP-OES) in 23 elements determination in geological samples.: This article details the application of microwave-induced plasma optical emission spectrometry for elemental analysis in geological samples. Hydrochloric acid solution is used in the sample preparation process to ensure accurate and efficient element extraction (Niedzielski et al., 2015).
Features and Benefits
This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
Packaging
Titripac® packaging - all SKU-pack size numbers ending "4000, 4003, 9010, 9013" - more information on www.sigmaaldrich.com/Titripac
Analysis Note
Amount-of-substance concentration 0.995 - 1.005 mol/L
Measurement uncertainty ± 0.003 mol/L
Traceability NIST SRM
The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 723 Tris(hydroxymethyl)aminomethane) by means of volumetric standard Tris(hydroxymethyl)aminomethane (article number 1.02408), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.
Other Notes
Legal Information
1 of 1
This Item | |||
|---|---|---|---|
| reaction suitability reaction type: Acid-base reactions | reaction suitability reaction type: Acid-base reactions | reaction suitability reaction type: Acid-base reactions | reaction suitability reaction type: Acid-base reactions |
| technique(s) titration: suitable | technique(s) titration: suitable | technique(s) titration: suitable | technique(s) titration: suitable |
| product line Titripur® | product line Titripur® | product line Titrisol® | product line Titrisol® |
| agency reag. Ph. Eur., reag. USP | agency reag. Ph. Eur., reag. USP, suitable for SM 2310, suitable for SM 2320 | agency - | agency - |
| storage temp. 15-25°C | storage temp. 15-25°C | storage temp. 15-25°C | storage temp. 15-25°C |
| density 1.02 g/cm3 at 20 °C | density 1.00 g/cm3 at 20 °C | density 1.09 g/cm3 at 20 °C | density 1.03 g/cm3 at 20 °C |
Still not finding the right product?
Explore all of our products under Hydrochloric acid solution
signalword
Warning
hcodes
pcodes
Hazard Classifications
Met. Corr. 1
Storage Class
12 - Non Combustible Liquids
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Protocols
Photometric determination of ammonium ions in mineral fertilizer samples by indophenol blue method using Spectroquant® test kits and spectrophotometer.
Photometric determination of ammonium ions in organic fertilizers by indophenol blue method using Spectroquant® test kits and spectrophotometer.
Photometric or turbidimetric determination subsequent to water extraction/fusion melting
Articles
LC/LC-MS method identifies 8 aminoglycosides in pork using Discovery® DSC-18 SPE and Ascentis® Express C18 UHPLC, per Chinese standards.
SmartChemicals enable wireless CoA data transfer, reducing human error in titration experiments.
Application Note: Peroxidase in vegetables – Visual determination after conversion of a specific substrate.
Related Content
Karl Fischer titration determines water content in raw materials and products, a widely used analytical method.
Global Trade Item Number
| SKU | GTIN |
|---|---|
| M72803-100ML | 04061837778612 |
| 1090579025 | 04022536110110 |
| 1090571003 | 04054839633270 |
| 1090575000 | 04022536110080 |
| 1090579013 | 04054839633294 |
| 1090572500 | 04022536110073 |
| 1090571000 | 04022536110059 |
| 1090579026 | 04022536687001 |
| 1090574000 | 04027269029722 |
| 1090574003 | 04054839633287 |
| 1090579010 | 04022536110103 |
-
Is 1090571000 Hydrochloric acid solution suitable for trace metal analysis? What is the purity? What are the concentrations of metals in this product? Thanks
1 answer-
Helpful?
-
-
How can I determine the shelf life / expiration / retest date of this product?
1 answer-
If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdfHelpful?
-
-
How is shipping temperature determined? And how is it related to the product storage temperature?
1 answer-
Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf
Helpful?
-