XX1014700

Millipore Classic Glass Filter Holder - Kit

47 mm, Glass frit membrane support, 300 mL funnel

Synonym(s):

Borosilicate glass filter holder

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
1 ea
Please contact Customer Service for Availability
4 670,00 kr

About This Item

UNSPSC Code:
41104909
NACRES:
NB.24
eCl@ss:
32031613

4 670,00 kr


Please contact Customer Service for Availability

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Level

material

anodized aluminum spring clamp(s), borosilicate glass base, borosilicate glass funnel(s), glass seal, silicone sleeve (for alignment), silicone stopper (parylene treated)

agency

suitable for EPA 1613, suitable for EPA 200.7, suitable for EPA 200.8, suitable for EPA 300

technique(s)

vacuum filtration: suitable

H

22.9 cm

diam.

7.6 cm

filter diam.

47 mm

filtration area

9.6 cm2

funnel capacity

300 mL

fitting

inlet funnel, No. 8 outlet stopper for standard 1 L and 4 L filtering flasks (perforated silicone)

application(s)

filtration

compatibility

for use with Classic Glass Filter Holder

shipped in

ambient

General description

Millipore Classic Glass Filter Holders - Kit
47 mm, Glass frit membrane support, 300 mL funnel

The Classic Glass Filter Holder is an essential tool for every research lab. The holder′s multipurpose design is appropriate for a variety of applications and is available in three different support materials for compatibility with your specific application needs.

This item is a Kit composed of the following items:
(Catalog Number - Description)
XX1014704 - Millipore Glass funnel, 300 mL, 47 mm, Borosilicate, Ground glass seal
XX1014703 - Millipore Spring Clamp, 47 mm, Aluminum
XX1014702 - Millipore Glass Base and Stopper, 47 mm, Glass frit membrane support
ALIGNED05 - Millipore Alignment Guide, 47 mm, 5/PK

Features & Benefits:
• Designed for easy loading and removal of membranes
• Three membrane support materials options to suit a variety of applications
• UV sterilize or autoclave with filter in place for bacteriological analysis

Applications:
General Filtration and Clarification, Bacteriological Analysis, Particulate Contamination Analysis of Oils and Hydraulic Fluids, Exfoliative Cytology

Application

47 mm, Glass frit membrane support, 300 mL funnel

Biochem/physiol Actions

Vacuum

Preparation Note

Sterilization Method
UV sterilize or autoclave without filter in-place

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
XX1014720XX1014730XX1514700
compatibility

for use with Classic Glass Filter Holder

compatibility

for use with Classic Glass Filter Holder

compatibility

for use with Classic Glass Filter Holder

compatibility

for use with All-Glass Filter Holder

fitting

inlet funnel, No. 8 outlet stopper for standard 1 L and 4 L filtering flasks (perforated silicone)

fitting

inlet funnel, No. 8 outlet stopper for standard 1 L and 4 L filtering flasks (perforated silicone)

fitting

inlet funnel, No. 8 outlet stopper for standard 1 L and 4 L filtering flasks (perforated silicone)

fitting

inlet funnel, 6 mm (1/4 in.) O.D. outlet tubulated cap sidearm for vacuum

material

anodized aluminum spring clamp(s), borosilicate glass funnel(s), silicone sleeve (for alignment), borosilicate glass base, silicone stopper (parylene treated), glass seal

material

PTFE seal, anodized aluminum spring clamp(s), borosilicate glass base, borosilicate glass funnel(s), parylene coating (on stopper), silicone sleeve (for alignment), silicone stopper

material

anodized aluminum spring clamp(s), borosilicate glass base, borosilicate glass funnel(s), glass seal, parylene coating (on stopper), silicone sleeve (for alignment), silicone stopper

material

anodized aluminum spring clamp(s), borosilicate glass base, borosilicate glass funnel(s), fritted glass support (for filter), silicone sleeve (for alignment), tubulated borosilicate glass cap

agency

suitable for EPA 200.7, suitable for EPA 300, suitable for EPA 1613, suitable for EPA 200.8

agency

suitable for EPA OTM-45

agency

-

agency

suitable for EPA 1633, suitable for ISO 21675 2019

shipped in

ambient

shipped in

ambient

shipped in

ambient

shipped in

ambient

technique(s)

vacuum filtration: suitable

technique(s)

vacuum filtration: suitable

technique(s)

vacuum filtration: suitable

technique(s)

vacuum filtration: suitable


Still not finding the right product?




Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Articles

Learn how filter selection and sample and mobile phase filtration impact HPLC back pressure and column lifetime.

Related Content

Find analytical tools for air and fluid particle contamination monitoring in industrial environments.

This page is intended to make it easier to find the consumables you need based on the analytical method you’re using. Methods included on this page come from the EPA, Standard Methods and ASTM.

View All Related Content




Global Trade Item Number

SKUGTIN
XX101470004054839426612

Questions

1–2 of 2 Questions  
  1. What is the alternative product for the discontinued product #XX1104704?

    1 answer
    1. The Glass-filter holders like XX1014700 can be used as an alternative for the discontinued product #XX1104704.

      Helpful?

  2. Is it possible to use Glass or Stainless Steel funnels with the manifolds? Are clamps shown on the website required for either of these funnels? Additionally, what are the recommendations for sanitizing these funnels?

    1 answer
    1. A glass funnel, XX1014700, is recommended and can be used with the manifold, EZFITH0LD1, EZFITH0LD3, or EZFITH0LD6, depending on the desired sample setup. It is advised to autoclave the glass funnel and base. While a stainless steel funnel is available, it is primarily used for flammable liquids due to its ability to be grounded and is relatively expensive.

      Helpful?