Merck
All Photos(1)

Documents

ZTC18M

Millipore

ZipTip® Pipette Tips

C18-silica gel resin, bed volume 0.2 μL, tip volume 10 μL

Sign Into View Organizational & Contract Pricing

Select a Size

eCl@ss:
32033590
NACRES:
NB.24

material

C18-silica gel resin
polypropylene

Quality Level

sterility

non-sterile

manufacturer/tradename

ZipTip®

parameter

4-70  °C temperature

technique(s)

analytical sample preparation: suitable
fractionation: suitable
protein purification: suitable (concentration)

bed volume

0.2 μL

thickness

15 μm

tip I.D.

3.375 mm

tip L

31 mm

tip O.D.

5.8 mm

tip volume

10 μL

pore size

200 Å pore size

pH

1.5-13.5
2-12(for 24 hour exposure)

capacity

2.0 μg binding capacity(typically; when used with saturating amounts of analyte)

shipped in

ambient

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
P3B010A00P3B010A01P3B050A05
parameter

4-70  °C temperature

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 5.5 bar max. inlet pressure (80 psi) at 30 °C, 5.5 bar max. transmembrane pressure (80 psig) at 30 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

parameter

30 psi max. reverse press. exposure at 25 °C (for 24 hours), 4-6 L/min-m2 recirculation rate, 40 psi max. transmembrane pressure at 4-50 °C, 6.9 bar max. inlet pressure (100 psi), 80 psi max. transmembrane pressure at 4-40 °C

technique(s)

analytical sample preparation: suitable, fractionation: suitable, protein purification: suitable (concentration)

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

technique(s)

analytical sample preparation: suitable, buffer exchange: suitable, protein purification: suitable (concentration)

pore size

200 Å pore size

pore size

10 kDa NMWCO

pore size

10 kDa NMWCO

pore size

50 kDa NMWCO

capacity

2.0 μg binding capacity(typically; when used with saturating amounts of analyte)

capacity

-

capacity

-

capacity

-

shipped in

ambient

shipped in

ambient

shipped in

-

shipped in

-

Application

ZipTip® with 0.2 µLC18 resin is suitable for mass spectrometry sample preparation and protein concentration.

Features and Benefits

  • One-step desalting, concentration, and purification
  • Allows fractionation of complex samples
  • Ideal for peptides, proteins, nucleic acids, and more
  • Maximum recovery without dead volume
  • Eliminates time-consuming chromatography

Other Notes

Automation Compatible: Yes

Legal Information

ZIPTIP is a registered trademark of Merck KGaA, Darmstadt, Germany

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 1

1 of 1

Ammonium bicarbonate ReagentPlus®, ≥99.0%

Sigma-Aldrich

A6141

Ammonium bicarbonate

Chen-Chung Liao et al.
Biology, 11(2) (2022-02-26)
Atherosclerosis is the preliminary cause of coronary artery disease, one of the diseases that account for the largest number of fatal mortalities. Physical activity is an effective strategy to restrain atherosclerosis from deterioration. Evidence indicated that changes in the proteomic
Bianca Silva Vieira de Souza et al.
Microbes and infection, 21(10), 456-463 (2019-05-11)
Staphylococcus saprophyticus is a gram-positive coagulase negative bacteria which shows clinical importance due to its capability of causing urinary tract infections (UTI), as well as its ability to persist in this environment. Little is known about how S. saprophyticus adapts to
Martha E Floy et al.
FASEB journal : official publication of the Federation of American Societies for Experimental Biology, 35(9), e21799-e21799 (2021-08-03)
Cardiac fibroblasts (CFBs) support heart function by secreting extracellular matrix (ECM) and paracrine factors, respond to stress associated with injury and disease, and therefore are an increasingly important therapeutic target. We describe how developmental lineage of human pluripotent stem cell-derived
Chenchang Bao et al.
Journal of proteomics, 226, 103891-103891 (2020-07-07)
Lysine crotonylation (Kcr) is a recently-discovered type of post-translational modification. Although Kcr has been reported in many species, little is known about this process in crustaceans. In this study, pan anti-lysine crotonylation antibody enrichment and high-resolution liquid chromatogram-mass spectrometry analysis
Alice Capuz et al.
Frontiers in immunology, 13, 882830-882830 (2022-07-06)
Spinal cord injury (SCI) represents a major medical challenge. At present, there is still no cure to treat it efficiently and enable functional recovery below the injury site. Previously, we demonstrated that inflammation determines the fate of the physiopathology. To

Protocols

Purification of Serum Peptides for MALDI Mass Spectrometry with Amicon® Ultra Centrifugal Filters

Biomarkers play an essential role in the drug discovery and development process.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service