跳转至内容
Merck

跳至

DX0835

二氯甲烷

Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

别名:

亚甲基氯

并加购,请在购物车里查看协议价、货期和发货地。

选择规格

变更视图
规格/货号是否有货价格

关于此项目

线性分子式:
CH2Cl2
化学文摘社编号:
分子量:
84.93
EC Index Number:
200-838-9
UNSPSC Code:
12352101
Beilstein/REAXYS Number:
1730800
MDL number:
NACRES:
NA.21
Assay:
≥99.5% (GC)
Bp:
39.8-40 °C (lit.)
Vapor pressure:
24.45 psi ( 55 °C), 6.83 psi ( 20 °C)
价格与库存信息目前不能提供
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


agency

meets USP/NF

Quality Segment

vapor density

2.9 (vs air)

vapor pressure

24.45 psi ( 55 °C), 6.83 psi ( 20 °C)

assay

≥99.5% (GC)

form

liquid

autoignition temp.

1223 °F

expl. lim.

22 %

dilution

(for analytical testing)

impurities

≤0.0003 meq/g Titrable acid, ≤0.02% Water (H2O)

evapn. residue

≤0.002%

color

APHA: ≤10

refractive index

n20/D 1.424 (lit.)

pH

7 (20 °C)

bp

39.8-40 °C (lit.)

mp

-95 °C, −95 °C (lit.)

density

1.325 g/mL at 25 °C (lit.)

shipped in

ambient

storage temp.

room temp

SMILES string

ClCCl

InChI

1S/CH2Cl2/c2-1-3/h1H2

InChI key

YMWUJEATGCHHMB-UHFFFAOYSA-N

General description

EMPARTA solvents are designed for routine chemical synthesis, drying, purification, and critical labware cleaning in quality control environments. Engineered for precision, they deliver consistently reproducible results essential for rigorous validation and documentation.

Exceptional Quality Standards: These solvents meet or exceed ACS specifications, providing assurance of high quality that is crucial for accurate testing and analysis in quality control.

Consistent Reproducibility: Designed for precision, the solvents ensure that results can be reliably reproduced, which is vital for maintaining compliance and integrity in quality control processes.

Versatile Applications: Suitable for a variety of QC tasks, including analytical testing, method validation, and testing USP/NF monographs, these solvents support a comprehensive approach to quality assurance in laboratory settings.

Application

DX0835P-4 is packaged in poly coated glass bottles
Stabilized with an alkene.
Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

Packaging

M-Bottle for Solvents
As a global leader in lab reagents, we are constantly looking for new ways to optimize the safety of our products. The newly developed 4L solvent bottle design features advanced sealing technology that eliminates leaks to make the handling of solvents safer and more convenient than ever before.
See all the new features here!

Analysis Note

Appearance: Clear Liquid
Assay (GC): 99.5% min
Color (APHA): 10 max
Evaporation residue: 0.002% max
Free halogens: To pass test
Infrared Spectrum: Conforms to standard
Titrable acid: 0.0003meq/g max
Water (H2O): 0.02% max
Evaporation Number: 1.9


Still not finding the right product?

Explore all of our products under 二氯甲烷


pictograms

Health hazardExclamation mark

signalword

Warning

Hazard Classifications

Carc. 2 - Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Central nervous system

存储类别

6.1D - Non-combustible acute toxic Cat.3 / toxic hazardous materials or hazardous materials causing chronic effects

wgk

WGK 2



历史批次信息供参考:

分析证书(COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our 文件 section.

如需帮助,请联系 客户支持

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库



Questions

1–2 of 2 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters