跳转至内容
Merck

跳至

SLGV004SL

Millex PVDF针头式过滤器

pore size 0.22 μm, diam. 4 mm, sterile, hydrophilic

Millex™ PVDF syringe filter
1 of 2 reviewers received a sample product or took part in a promotion

别名:

0.22 μm PVDF针头式过滤器, Durapore® PVDF针头式过滤器, Millex-GS针头式过滤器

登录 查看组织和合同定价。

选择尺寸

变更视图
包装规格货号是否有货价格

关于此项目

UNSPSC Code:
41104922
NACRES:
NB.22
eCl@ss:
32031690
Pore size:
0.22 μm
Diam.:
4 mm
Sterility:
ethylene oxide treated, sterile
Material:
PVDF membrane, high-density polyethylene housing
价格与库存信息目前不能提供
技术服务
需要帮助?我们经验丰富的科学家团队随时乐意为您服务。
让我们为您提供帮助


Quality Level

material

PVDF membrane, high-density polyethylene housing

sterility

ethylene oxide treated, sterile

product line

Millex

shelf life

3 yr

feature

holdup volume< 10 μL, hydrophilic

manufacturer/tradename

Millex

parameter

14 bar max. inlet pressure (200 psi), 45 °C max. temp.

technique(s)

low protein-binding filtration: suitable, sterile filtration: suitable

diam.

4 mm

filtration area

0.1 cm2

housing diam.

6.4 mm

inlet to outlet H

19.7 mm

volume

1 mL

matrix

Durapore®

pore size

0.22 μm

input

aqueous solution(s)
tissue culture medium

fitting

female Luer-Lok® inlet, male Luer outlet stepped slip

shipped in

ambient

storage temp.

no temp limit

Legal Information

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
Luer-Lok is a registered trademark of Becton-Dickinson & Co.
Millex is a trademark of Merck KGaA, Darmstadt, Germany


Still not finding the right product?

Explore all of our products under Millex PVDF针头式过滤器

或者

试用我们的 产品选型工具 工具缩小选择范围




分析证书(COA)

输入产品批号来搜索 分析证书(COA) 。批号可以在产品标签上"批“ (Lot或Batch)字后找到。

已有该产品?

在文件库中查找您最近购买产品的文档。

访问文档库


商品

Select the right sterile filter by media, volume, and application.


Magfur E Alam et al.
Journal of pharmaceutical sciences, 109(1), 656-669 (2019-11-05)
Monoclonal antibodies are attractive therapeutic agents because of their impressive biological activities and favorable biophysical properties. Nevertheless, antibodies are susceptible to various types of chemical modifications, and the impact of such modifications on antibody physical stability and aggregation remains understudied.



全球贸易项目编号

货号GTIN
SLGV004SL08436037120312

Questions

  1. Quel type de seringue je peux utiliser avec Filtre SLGV004SL (pour filtration des anticorps) ?

    1 answer
    1. Syringes smaller than 10 mL should not be used, as pressures exceeding the maximum pressure rating may occur, potentially causing damage to the syringe filter and personal injury. The syringe should have a male Luer Lok, as the filter has a female Luer Lok inlet. The device is 6.4 mm wide and accepts a male Luer inlet smaller than this.

      Helpful?

Reviews

Active Filters

  1. Seattle, WA
    • Review 1
    • Votes 4
    1 out of 5 stars.

    Cannot get sterile water to flow through.

    I used this to filter an antibody and the could not push any volume through the filter. I assumed that I must have a precipitate in my solution. However, I then tried sterile water to make sure the product worked. Absolutely nothing went through without an incredible amount of force. I tried twice with new filters. These say they're for aqueous phase and are hydrophilic, but that is not at all how they're behaving.

    Helpful?

    1. Response from Merck KGaA:

      Thank you for taking the time to leave a review! There is no history of similar complaints for this product. We would be happy to discuss this further so we can document this issue for the lot you received and possibly issue a replacement. When you have a moment, please contact us by visiting https://www.sigmaaldrich.com/support/customer-support and submit a Report Product Issue ticket. We look forward to hearing from you soon!

  2. 1 Ratings-only review