Merck
所有图片(3)

34998

Sigma-Aldrich

乙腈

HPLC Plus, ≥99.9%

别名:
乙腈, 甲基氰, 氰甲烷, ACN
线性分子式:
CH3CN
CAS号:
分子量:
41.05
Beilstein:
741857
EC 号:
MDL编号:
eCl@ss:
39031501
PubChem化学物质编号:
NACRES:
NA.03

质量水平

100

等级

HPLC Plus

蒸汽密度

1.41 (vs air)

蒸汽压

72.8 mmHg ( 20 °C)

测定

≥99.9%

形式

liquid

自燃温度

973 °F

expl. lim.

16 %

baseline drift measuring range

≤12 mAU (210 nm)

technique(s)

HPLC: suitable
IR spectroscopy: suitable

杂质

≤0.0001% free alkali (as NH3)
≤0.0002% non-volatile matter
≤0.001% free acid (as CH3COOH)
≤0.01% water (Karl Fischer)
≤0.5 ppb fluorescence (quinine) at 254 nm
≤0.5 ppb fluorescence (quinine) at 365 nm

卤代烷残留物

10 ng/L (as heptachlor epoxide)

折射率

n20/D 1.344 (lit.)

bp

81-82 °C (lit.)

mp

−45 °C (lit.)

密度

0.786 g/mL at 25 °C (lit.)

HPLC-gradient

≤0.2 mAU at 254 nm
≤1 mAU at 210 nm

λ

H2O reference

紫外吸收

λ: 195 nm Amax: ≤0.10
λ: 200 nm Amax: ≤0.02
λ: 228 nm Amax: ≤0.005
λ: 235 nm Amax: ≤0.0044
λ: 250 nm Amax: ≤0.0044
λ: 400 nm Amax: ≤0.0044

application(s)

food and beverages

SMILES string

CC#N

InChI

1S/C2H3N/c1-2-3/h1H3

InChI key

WEVYAHXRMPXWCK-UHFFFAOYSA-N

正在寻找类似产品? Visit 产品对比指南

相关类别

一般描述

乙腈(MeCN)在各种研究中广泛用作溶剂,具有高介电常数(37.5)。许多研究人员已报道了各种纯化方法,以获得用于不同研究(极谱法、光谱学等)的不同等级的乙腈。

应用

全新品质的UPLC Plus乙腈适用于所有应用,包括:
质谱,HPLC,TLC,GPC,UV,IR,GC,农药残留分析以及RNA/DNA合成和纯化。
乙腈已被用于组成梯度系统,用于HPLC检测二苯基甲烷二异氰酸酯,一种聚合物降解产物。

包装

200 L in Pure-Pac™ 2
1, 6×1, 2.5, 4×2.5, 4, 4×4 L in glass bottle
20 L in Nowpak™
20, 50 L in Pure-Pac™ 2
200 L in Pure-Pac™ 1

制备说明

本品经过0.2 μ过滤器过滤

其他说明

Pure-Pac® II容器需要用Micromatic MacroValve耦合器来分配溶剂, Z560723
重要通知
  • 货号 34998-4X2.5L的产品即将停产。请订购34998-2.5L单瓶装,因为其具体参数与上述产品本质相同。
  • 货号34998-6X1L的产品即将停产。请订购34998-1L单瓶装,因为其物理参数与上述产品本质相同。

推荐产品

探索最适于 HPLCLC-MS 分析的 LiChropur 试剂

法律信息

Pure-Pac is a registered trademark of Sigma-Aldrich Co. LLC

象形图

FlameExclamation mark

警示用语:

Danger

危险分类

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Eye Irrit. 2 - Flam. Liq. 2

储存分类代码

3 - Flammable liquids

WGK

WGK 2

闪点(F)

35.6 °F - closed cup

闪点(C)

2.0 °C - closed cup

分析证书

请输入批号搜索分析证书(COA)。

原产地证书 (CofO)

请输入批号搜索原产地证书(COO)。

  1. Which document(s) contains shelf-life or expiration date information for a given product?

    If available for a given product, the recommended re-test date or the expiration date can be found on the Certificate of Analysis.

  2. How do I get lot-specific information or a Certificate of Analysis?

    The lot specific COA document can be found by entering the lot number above under the "Documents" section.

  3. Who do I contact about larger solvent volume needs?

    Email us at labessentials@sial.com or visit Sigma-Aldrich Fine Chemicals for development and manufacturing-scale inquiries: safcglobal@sial.com

  4. How do I know what packaging options are available for a solvent?

    The Solvent Center gives you the ability to review all the specifications associated with our solvent packaging. This includes physical dimensions, closure types, dispensing methods, UN/DOT Rating as well as solvent compatibility. Visit the Solvent Center.

  5. Who do I contact if I need a solvent blend, which you do not carry?

    Email us at labessentials@sial.com. For a complete listing of all our Solvent blends, visit the Solvent Center

  6. The dispensing of solvents provides some challenges due to the number of container options available. What dispensing options are available for each container?

    The Sigma-Aldrich Solvent Center provides numerous dispensing options for each container type. For a complete listing of all our dispensing options, visit the Solvent Center.

  7. Which solvent grade should I be using for my application?

    Sigma-Aldrich Solvent Applications Table gives a guideline to common applications and the appropriate solvent grades.  Visit: Solvents

  8. What are the options for drying solvents? 

    Sigma-Aldrich offers a full range of high-purity solvents with extremely low water levels specifically manufactured for moisture sensitive Organic and Biotech applications.  Sigma-Aldrich also carries various drying agents such as molecular sieves, which are typically compatible with organic solvents.

  9. What apparatus do you recommend for HPLC solvent filtration?

    The Sigma-Aldrich Vacuum Filtration Assembly gives you all the components you need including: funnel top, fritted glass funnel support, filtration flask, aluminum clamp, and silicone stopper.  The Acrodisc Syringe Filters offer high quality filtration for analytical samples, certified for HPLC to ensure low extractable and available in a broad range of membranes to meet sample compatibility requirements.

  10. Can you recommend a Solvent Extractor for organics from aqueous solution?

    Solvent extractors are often used for the quantitative extraction of organics from aqueous solutions and separations in immunoassays. The MIXXOR system has been applied successfully in many laboratory solvent extraction operations and is ideal for the rapid screening of alternative solvents for specific extraction problems.

  11. How do I find price and availability?

    There are several ways to find pricing and availability for our products. Once you log onto our website, you will find the price and availability displayed on the product detail page. You can contact any of our Customer Sales and Service offices to receive a quote.  USA customers:  1-800-325-3010 or view local office numbers.

  12. What is the Department of Transportation shipping information for this product?

    Transportation information can be found in Section 14 of the product's (M)SDS.To access the shipping information for this material, use the link on the product detail page for the product. 

  13. My question is not addressed here, how can I contact Technical Service for assistance?

    Ask a Scientist here.

H Haugen et al.
Journal of biomedical materials research. Part B, Applied biomaterials, 73(2), 229-237 (2005-03-10)
This article deals with enzyme-induced biodegradation behavior of thermoplastic polyether-urethane (TPU). Porous scaffolds were processed by a new foaming method applied in hot pressing and injection molding. The scaffolds were subsequently gamma sterilized. The samples were incubated with cholesterol esterase
Alexander David Ardianrama et al.
Journal of colloid and interface science, 552, 485-493 (2019-06-04)
Although triangular silver (Ag) nanoplates are intrinsically unstable, this characteristic has been taken advantage of in the development of a novel sensing platform. However, most of these applications have relied on halide ions as etchants. In the current work, we
Purification of acetonitrile.
Walter M and Ramaley L.
Analytical Chemistry, 45(1), 165-166 (1973)
Timo Glatter et al.
Molecular systems biology, 5, 237-237 (2009-01-22)
Protein complexes represent major functional units for the execution of biological processes. Systematic affinity purification coupled with mass spectrometry (AP-MS) yielded a wealth of information on the compendium of protein complexes expressed in Saccharomyces cerevisiae. However, global AP-MS analysis of
Divya Subramonian et al.
Journal of proteome research, 13(9), 3905-3918 (2014-07-30)
SUMOylation is an essential posttranslational modification and regulates many cellular processes. Dysregulation of SUMOylation plays a critical role in metastasis, yet how its perturbation affects this lethal process of cancer is not well understood. We found that SUMO-2/3 modification is

实验方案

HPLC Analysis of Paraquat and Diquat on Ascentis® Express HILIC (UV Detection)

HPLC Analysis of Paraquat and Diquat on Ascentis® Express HILIC (UV Detection)

HPLC Analysis of Vitamins B1 B6 B12

HPLC Analysis of Vitamins B1, B6 and B12 using Ascentis® Express RP-Amide

相关内容

Extended Lifetime Ethanol Metabolites and Method Development for Ethyl Sulfate and Ethyl Glucuronide Separation

Review of clinically relevant ethanol metabolites and analytical method development for the analysis of ethyl glucuronide and ethyl sulfate in urine matrix.

HPLC Analysis of Polyglutamate Metabolites of Methotrexate on TSKgel® NH2-100 and ODS-100V

Separation of Methotrexate (MTX)-PG; Methotrexate (MTX)-PG2; Methotrexate (MTX)-PG3 ; Methotrexate (MTX)-PG4; Methotrexate (MTX)-PG5; Methotrexate (MTX)-PG6; Methotrexate (MTX)-PG7

HPLC Analysis of Polyglutamate Metabolites of Methotrexate on TSKgel® NH2-100 and ODS-100V

Separation of Methotrexate (MTX)-PG; Methotrexate (MTX)-PG2; Methotrexate (MTX)-PG3 ; Methotrexate (MTX)-PG4; Methotrexate (MTX)-PG5; Methotrexate (MTX)-PG6; Methotrexate (MTX)-PG7

我们的科学家团队拥有各种研究领域经验,包括生命科学、材料科学、化学合成、色谱、分析及许多其他领域.

联系技术服务部门