Millipore Classic Glass Filter Holder - Kit

47 mm, Stainless steel screen membrane support, 300 mL funnel

Synonym(s):

Millipore filter holder

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
1 ea

Estimated to ship on24 September 2026fromMerck Life Science spol. s r.o

€513.00

About This Item

UNSPSC Code:
41104909
NACRES:
NB.24
eCl@ss:
32031613
Material:
anodized aluminum spring clamp(s), borosilicate glass base, borosilicate glass funnel(s), glass seal, parylene coating (on stopper), silicone sleeve (for alignment), silicone stopper

€513.00


Estimated to ship on24 September 2026Details


Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Segment

material

anodized aluminum spring clamp(s), borosilicate glass base, borosilicate glass funnel(s), glass seal, parylene coating (on stopper), silicone sleeve (for alignment), silicone stopper

technique(s)

vacuum filtration: suitable

H

22.9 cm

diam.

7.6 cm

filter diam.

47 mm

filtration area

9.6 cm2

fitting

inlet funnel, No. 8 outlet stopper for standard 1 L and 4 L filtering flasks (perforated silicone)

application(s)

filtration

compatibility

for use with Classic Glass Filter Holder

shipped in

ambient

General description

Millipore Classic Glass Filter Holders - Kit
47 mm, Stainless steel screen membrane support, 300 mL funnel

The Classic Glass Filter Holder is an essential tool for every research lab. The holder′s multipurpose design is appropriate for a variety of applications and is available in three different support materials for compatibility with your specific application needs.

This item is a Kit composed of the following items:
(Catalog Number - Description)
XX1014704 - Millipore Glass funnel, 300 mL, 47 mm, Borosilicate, Ground glass seal
XX1014703 - Millipore Spring Clamp, 47 mm, Aluminum
XX1014732 - Millipore Glass Base and Stopper, 47 mm, For use with stainless steel screen support, Screen provided
ALIGNED05 - Millipore Alignment Guide, 47 mm, 5/PK

Features & Benefits:
• Designed for easy loading and removal of membranes
• Three membrane support materials options to suit a variety of applications
• UV sterilize or autoclave with filter in place for bacteriological analysis

Applications:
General Filtration and Clarification, Bacteriological Analysis, Particulate Contamination Analysis of Oils and Hydraulic Fluids, Exfoliative Cytology

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
XX5014700XX1014720XX1514700
description

47 mm, Stainless steel screen membrane support, 300 mL funnel

description

47 mm, Glass frit membrane support, 500 mL funnel

description

47 mm, PTFE-coated membrane support, 300 mL funnel

description

47 mm, Glass frit membrane support, 300 mL funnel

material

borosilicate glass base, anodized aluminum spring clamp(s), parylene coating (on stopper), borosilicate glass funnel(s), silicone stopper, glass seal, silicone sleeve (for alignment)

material

borosilicate glass funnel(s), silicone sleeve (for alignment), glass seal, anodized aluminum spring clamp(s), borosilicate glass base, parylene coating (on stopper), silicone stopper

material

PTFE seal, parylene coating (on stopper), silicone stopper, anodized aluminum spring clamp(s), borosilicate glass base, borosilicate glass funnel(s), silicone sleeve (for alignment)

material

silicone sleeve (for alignment), borosilicate glass funnel(s), anodized aluminum spring clamp(s), fritted glass support (for filter), borosilicate glass base, tubulated borosilicate glass cap

application(s)

filtration

application(s)

filtration

application(s)

PFAS testing
filtration

application(s)

PFAS testing
filtration

technique(s)

vacuum filtration: suitable

technique(s)

vacuum filtration: suitable

technique(s)

vacuum filtration: suitable

technique(s)

vacuum filtration: suitable

Quality Level

100

Quality Level

100

Quality Level

100

Quality Level

100

filter diam.

47 mm

filter diam.

47 mm

filter diam.

47 mm

filter diam.

47 mm

filtration area

9.6 cm2

filtration area

9.6 cm2

filtration area

9.6 cm2

filtration area

9.6 cm2


Still not finding the right product?




Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–2 of 2 Questions  
  1. The photo of the kit shows that the Millipore Vacuum Filtering Side-Arm Flask is included. The description doesn't taik about it. What's going on here?

    1 answer
    1. The side-arm flask is not included with the kit, and must be purchased separately. Please refer to the Description section above:

      This item is a Kit composed of the following items:
      (Catalog Number - Description)
      XX1014704 - Millipore Glass funnel, 300 mL, 47 mm, Borosilicate, Ground glass seal
      XX1014703 - Millipore Spring Clamp, 47 mm, Aluminum
      XX1014732 - Millipore Glass Base and Stopper, 47 mm, For use with stainless steel screen support, Screen provided
      ALIGNED05 - Millipore Alignment Guide, 47 mm, 5/PK

      Helpful?

  2. For this p/n: XX1014730, what is the pore / web size of this SS screen support? We will use p/n NY1004700, 10.0 μm Pore Size Nylon Membrane Filter on it with your Glass Filter Holder, and we hope the screen pore size is larger than 10 um.

    1 answer
    1. The mesh size is 125 um.