Skip to Content
Merck
  • Efficient analysis of selected estrogens using fabric phase sorptive extraction and high performance liquid chromatography-fluorescence detection.

Efficient analysis of selected estrogens using fabric phase sorptive extraction and high performance liquid chromatography-fluorescence detection.

Journal of chromatography. A (2014-08-02)
Rajesh Kumar, Gaurav, Heena, Ashok Kumar Malik, Abuzar Kabir, Kenneth G Furton
ABSTRACT

A simple, fast and sensitive analytical method using fabric phase sorptive extraction (FPSE) followed by high performance liquid chromatography with fluorescence detection (HPLC-FLD) has been developed for efficient quantification of biologically important molecules e.g., 17α-ethynylestradiol (EE2), β-estradiol (E2) and bisphenol A (BPA). FPSE is a new sorptive extraction technique that integrates the advantages of permeable sol-gel derived hybrid organic-inorganic sorbents with flexible and permeable fabric substrates, resulting in a highly efficient and sensitive extraction media that can be introduced directly into any kind of fluidic matrix. Various factors affecting the performance of FPSE technique were optimized. The chromatographic separation was carried using mobile phase acetonitrile/methanol/water (30:15:55; v/v) at a flow rate 1.0mL/min on C18 column with fluorescence detection (λex=280nm and λem=310nm). The calibration curves of the target analytes were prepared with good correlation coefficient values (R(2)>0.992). Limit of detection (LOD) values range from 20 to 42pg/mL. The developed method was applied successfully for the analysis of estrogen molecules in urine and various kinds of aqueous samples.

MATERIALS
Product Number
Brand
Product Description

Supelco
Sodium hydroxide concentrate, 0.1 M NaOH in water (0.1N), Eluent concentrate for IC
Sigma-Aldrich
Methanol, suitable for NMR (reference standard)
Sigma-Aldrich
Acetone, natural, ≥97%
Sigma-Aldrich
Acetone, ≥99%, FCC, FG
Supelco
Sodium hydroxide solution, 49-51% in water, eluent for IC
Sigma-Aldrich
Sodium hydroxide, BioUltra, suitable for luminescence, ≥98.0% (T), pellets
Supelco
Methanol, analytical standard
Supelco
Acetone, analytical standard
Sigma-Aldrich
Sodium hydroxide solution, BioUltra, Molecular Biology, 10 M in H2O
Sigma-Aldrich
Methanol, anhydrous, 99.8%
Sigma-Aldrich
3-Ethyl-2,4-pentanedione, mixture of tautomers, 98%
Sigma-Aldrich
Acetone, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Sodium hydroxide solution, 1.0 N, BioReagent, suitable for cell culture
Sigma-Aldrich
Sodium hydroxide, anhydrous, free-flowing, Redi-Dri, reagent grade, ≥98%, pellets
Supelco
Acetonitrile(Neat), Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Residual Solvent - Acetonitrile(solution in DMSO), Pharmaceutical Secondary Standard; Certified Reference Material
Sigma-Aldrich
Methanol, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Acetone, suitable for HPLC, ≥99.8%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, ≥99.9%
Sigma-Aldrich
Methanol, suitable for HPLC, gradient grade, suitable as ACS-grade LC reagent, ≥99.9%
Sigma-Aldrich
Acetone, HPLC Plus, for HPLC, GC, and residue analysis, ≥99.9%
Sigma-Aldrich
Acetone, suitable for HPLC, ≥99.9%
Sigma-Aldrich
Methanol, HPLC Plus, ≥99.9%
Sigma-Aldrich
Methanol, Laboratory Reagent, ≥99.6%
Supelco
Acetone, Pharmaceutical Secondary Standard; Certified Reference Material
Supelco
Methanol, Pharmaceutical Secondary Standard; Certified Reference Material
USP
Acetone, United States Pharmacopeia (USP) Reference Standard
Sigma-Aldrich
Acetone, ACS reagent, ≥99.5%
Sigma-Aldrich
Acetone, Laboratory Reagent, ≥99.5%
Sigma-Aldrich
Sodium hydroxide, puriss. p.a., ACS reagent, K ≤0.02%, ≥98.0% (T), pellets