Skip to Content
Merck
  • Microextraction by packed sorbent (MEPS) to analyze catecholamines in innovative biological samples.

Microextraction by packed sorbent (MEPS) to analyze catecholamines in innovative biological samples.

Journal of pharmaceutical and biomedical analysis (2014-12-17)
Maria Addolorata Saracino, Laura Santarcangelo, Maria Augusta Raggi, Laura Mercolini
ABSTRACT

A new microextraction by packed sorbent (MEPS) procedure coupled to a high-performance liquid chromatographic method has been developed for quantitation of catecholamines (i.e. norepinephrine, epinephrine and dopamine) in innovative biological samples, namely dried plasma and urine spots. Analyses were carried out on a C18 reversed-phase column using a mobile phase composed of 2.5% methanol and 97.5% aqueous citrate buffer, containing octanesulfonic acid. Coulometric detection was used, setting the first analytical cell at -0.350 V and the second analytical cell at +0.400 V. Dried matrices were purified by means of a fast and feasible MEPS procedure, optimized on C18 sorbent and requiring only a small amount of biological sample. The availability of miniaturized procedures allowed satisfying specific requirements that ought to be considered during pre-treatment intended for catecholamine analysis. The extraction yield values were always higher than 85% and sensitivity was good, with a limit of quantitation of 100 pg mL(-1) for all the analytes. Satisfactory results were also obtained in terms of linearity, precision and accuracy. The method was successfully applied to dried plasma and urine spots derived from two socially diversified groups, namely psychiatric patients and poly-drug abusers, in comparison to healthy volunteers.

MATERIALS
Product Number
Brand
Product Description

Sigma-Aldrich
Tetrabutylammonium bromide, ReagentPlus®, ≥99.0%
Sigma-Aldrich
Tetrabutylammonium bromide solution, 50 wt. % in H2O
Sigma-Aldrich
Phosphoric acid, 85 wt. % in H2O, 99.99% trace metals basis
Sigma-Aldrich
Phosphoric acid-16O4 solution, 70 wt. % in D2O, 99.9 atom % 16O
Sigma-Aldrich
Sodium hydroxide-16O solution, 20 wt. % in H216O, 99.9 atom % 16O
Sigma-Aldrich
trans,trans-1,4-Diphenyl-1,3-butadiene, 98%
Sigma-Aldrich
Methanol solution, suitable for NMR (reference standard), 4% in methanol-d4 (99.8 atom % D), NMR tube size 3 mm × 8 in.
Sigma-Aldrich
Citric acid, ACS reagent, ≥99.5%
Sigma-Aldrich
Sodium phosphate dibasic, 99.95% trace metals basis
Sigma-Aldrich
Potassium phosphate monobasic, 99.99% trace metals basis
Sigma-Aldrich
Ammonium-14N chloride, 99.99 atom % 14N, 15N-depleted, 99% (CP)
Sigma-Aldrich
Tetrabutylammonium bromide, ACS reagent, ≥98.0%
Sigma-Aldrich
Hydrogen chloride, ReagentPlus®, ≥99%
Sigma-Aldrich
Citric acid, ≥99.5%, FCC, FG
Sigma-Aldrich
Ethylenediaminetetraacetic acid, 99.995% trace metals basis
Sigma-Aldrich
Phosphoric acid, crystalline, ≥99.999% trace metals basis
Sigma-Aldrich
Phosphoric acid, BioUltra, ≥85% (T)
Sigma-Aldrich
Phosphoric acid, puriss., ≥99%
Sigma-Aldrich
Ethylenediaminetetraacetic acid, BioUltra, ≥99.0% (KT)
Sigma-Aldrich
Sodium 1-octanesulfonate monohydrate, ≥97.0% (T)
Supelco
Sodium 1-octanesulfonate monohydrate, ≥99.0% (T)
Sigma-Aldrich
Urea, puriss. p.a., ACS reagent, reag. Ph. Eur., ≥99%
Supelco
Ammonium ion solution for ISE, 1000 mg/kg N, analytical standard (for ion-selective electrodes)
Sigma-Aldrich
Urea, BioUltra, Molecular Biology, 99% (T)
Sigma-Aldrich
Citric acid, BioUltra, anhydrous, ≥99.5% (T)
Supelco
Sodium 1-octanesulfonate monohydrate, suitable for ion pair chromatography, LiChropur, ≥99.0% (T)
Sigma-Aldrich
Potassium phosphate monobasic, tested according to Ph. Eur., anhydrous
Supelco
Tetrabutylammonium bromide, suitable for ion pair chromatography, LiChropur, ≥99.0%
Sigma-Aldrich
1,2-Dihydroxybenzene, ReagentPlus®, ≥99%
Sigma-Aldrich
Phosphoric acid, ≥85 wt. % in H2O, ≥99.999% trace metals basis