# Ion-Suppression & Phospholipid Contamination
__HybridSPE®-Phospholipid Technology__
In pharmaceutical bioanalysis, researchers develop and run various assays to quantitate drugs, pharmaceutical candidates, and their metabolites in biological fluids such as serum or plasma. The data resulting from these assays are used to help determine the pharmacodynamic and pharmacokinetic properties as well as the toxic and therapeutic concentrations of existing and emerging pharmaceutical compounds. Although advances in LC-MS technology have reaped overwhelming benefits in terms of increased throughput and sensitivity, good sample preparation continues to be a critical component of bioanalysis.
__Section Overview__
- [Phospholipids & Ion-Suppression](https://www.sigmaaldrich.com#phospholipids-and-ion-suppression)
- [Why are Phospholipids Difficult to Remove During Sample Prep?](https://www.sigmaaldrich.com#difficult-to-remove)
- [Related Products](https://www.sigmaaldrich.com#products)
## [](https://www.sigmaaldrich.com)Phospholipids & Ion-Suppression
Excessive background from endogenous matrix components has always been a greater concern in bioanalysis, and has become paramount with decreasing analytical run times. In bioanalytical mass spectrometry, the issue of excessive background contributes to the growing problem of ion-suppression.
Ion-suppression is caused by one or more interfering components or species that co-elute with analyte(s) of interest during LC-MS analysis and manifests itself as a loss of analyte response. These co-eluting species can affect droplet formation or ionize concurrently resulting in an erroneous decrease (suppression) or increase (enhancement) in signalresponse. The end result is poor assay reproducibility, accuracy, and sensitivity. Such deleterious effects are often most notable at the lower limits of quantiation (LLOQ).
One of the major causes of ion-suppression in bioanalysis is the presence of phospholipids during LC-MS analysis in the positive ion electrospray mode (+ESI). Phospholipids are prevalent in extremely high concentrations in blood based biological fluids (~1 mg/mL); and represent the second largest lipid component in biological matrices after triglycerides. Figure 1 compares the LC-MS chromatograms of two clonidine spiked rat plasma samples processed by standard protein precipitation alone and protein precipitation followed by phospholipid removal. When standard protein precipitation was employed, severe signal suppression of clonidine was evident. In contrast, by removing phospholipid interferences prior to analysis, response for clonidine was nearly doubled.
## [](https://www.sigmaaldrich.com)Why are Phospholipids Difficult to Remove During Sample Prep?
When processing plasma/serum samples for LC-MS, the three most common sample prep techniques are protein precipitation (protein ppt), liquid-liquid extraction (LLE), and solid phase extraction (SPE). Each technique offers unique advantages that are considered during the method development process. For example, protein ppt methods are simple (2-3 steps), fast, and often require no method development. However, the technique offers minimal selectivity as it only removes gross levels of protein from the sample prior to analysis. In contrast, SPE offers significant benefits in terms of selectivity/sample cleanup, but the technique requires moderate to extensive levels of expertise and time for adequate method development. In addition, SPE often requires multiple steps (5-8) resulting in increased assay time.
Due to the nature of phospholipids, none of the mainstream sample prep techniques (protein ppt, LLE, and SPE) offer the proper selectivity to distinguish phospholipids from analytes of interest. Figure 2 describes this phenomenon.

__Figure 1.__Phospholipid effect on ionization of clonidine

__Figure 2.__Phospholipids co-extract with analytes of interest when using traditional sample prep techniques
__Protein PPT – No phospholipid removal__
- Will only remove gross levels of proteins
__LLE – No phospholipid removal__
A. Phospholipids will co-extract with analytes due to hydrophobic tail
__SPE – Nominal phospholipid removal__
B. Reversed-phase – phospholipids will co-extract with analytes due to hydrophobic tail
C. Mixed-mode/ion-exchange – phospholipids will co-extract with analytes due to zwitterionic polar head group
## Related Products
抱歉,發生意外錯誤。
Response not successful: Received status code 500
__Related Articles__
- [Determination of Formaldehyde and Acetaldehyde in Air Using DNPH Cartridges and Automated On-Line Desorption Followed by HPLC](https://www.sigmaaldrich.com/TW/en/technical-documents/protocol/environmental-testing-and-industrial-hygiene/air-testing/aldehydes-air-dnph)
- [Effect of Container Materials on Milk Off-Flavors](https://www.sigmaaldrich.com/TW/en/technical-documents/technical-article/analytical-chemistry/gas-chromatography/container-materials)
- [Pesticide Residue Analysis in Ginger Powder with QuEChERS](https://www.sigmaaldrich.com/TW/en/technical-documents/technical-article/analytical-chemistry/quechers/analysis-of-pesticide-residues-in-ginger-powder)
- [Analysis of Pesticide Residues in Pistachios Using QuEChERS Extraction and Cleanup with Supel™ QuE Z-Sep+](https://www.sigmaaldrich.com/TW/en/technical-documents/technical-article/analytical-chemistry/quechers/analysis-of-pesticide-residues-in-pistachios)
- [HybridSPE-Phospholipid Technology](https://www.sigmaaldrich.com/TW/en/technical-documents/technical-article/analytical-chemistry/small-molecule-hplc/hybridspe-precipitation-technology)
- [Impact of Mobile Phase Additives on LC-MS Sensitivity, Demonstrated using Spice Cannabinoids](https://www.sigmaaldrich.com/TW/en/technical-documents/technical-article/analytical-chemistry/small-molecule-hplc/lcms-spice-cannabinoids)
- [Solvent Analysis for 40 Per and Polyfluoroalkyl Substances](https://www.sigmaaldrich.com/TW/en/technical-documents/technical-article/analytical-chemistry/small-molecule-hplc/solvent-analysis-for-40-per-and-polyfluoroalkyl-substances)
- [Analysis of Drugs of Abuse in Urine](https://www.sigmaaldrich.com/TW/en/technical-documents/technical-article/analytical-chemistry/solid-phase-extraction/analysis-of-drugs-of-abuse-in-urine-after-cleanup-with-hlb)
- [View More](https://www.sigmaaldrich.com/TW/en/search/facet-search?focus=sitecontent&term=facet-search)
__Related Product Categories__
- [Solid Phase Extraction (SPE) and QuEChERS](https://www.sigmaaldrich.com/TW/en/products/analytical-chemistry/analytical-sample-preparation/spe-and-quechers)
頂部
__登入以繼續__
若要繼續閱讀,請登入或建立帳戶。
登入__還沒有帳戶?__註冊
支援[客戶支援](https://www.sigmaaldrich.com/TW/zh/support/customer-support)[聯絡我們](https://www.sigmaaldrich.com/TW/zh/collections/offices)[常見問題](https://maestro.my.site.com/knowledgeportal/s/)[安全資料表 (SDS)](https://www.sigmaaldrich.com/TW/zh/documents-search?tab=sds)[證書 (COA/COO)](https://www.sigmaaldrich.com/TW/zh/documents-search?tab=coa)[品質與法規](https://www.sigmaaldrich.com/TW/zh/life-science/quality-and-regulatory-management)[計算機與應用程式](https://www.sigmaaldrich.com/TW/zh/support/calculators-and-apps)[網路研討會](https://www.sigmaaldrich.com/TW/zh/collections/webinars)
訂單[訂單查詢](https://www.sigmaaldrich.com/TW/zh/order-lookup)[快速訂購](https://www.sigmaaldrich.com/TW/zh/quick-order)[客製化產品](https://www.sigmaaldrich.com/TW/zh/services/custom-products)[電子商務解決方案](https://www.sigmaaldrich.com/TW/zh/life-science/ecommerce/ecommerce-solutions)
公司簡介[關於我們](https://www.sigmaaldrich.com/TW/zh/life-science/about-us)[責任](https://www.sigmaaldrich.com/TW/zh/life-science/ssbi)[活動](https://www.sigmaaldrich.com/TW/zh/collections/events)[新聞稿](https://www.sigmaaldrich.com/TW/zh/collections/press)[節目](https://www.sigmaaldrich.com/TW/zh/life-science/partnership-programs)[工作機會](https://careers.merckgroup.com/global/en)[辦公室](https://www.sigmaaldrich.com/TW/zh/collections/offices)
社交媒體
[](https://www.linkedin.com/company/merck-life-science)
[](https://x.com/Merck_lifesci)
[](https://www.facebook.com/Merck.lifescience)
[](https://www.instagram.com/mercklifescience/)
[](https://www.youtube.com/@MerckLifeScience/featured)
Merck
__Research.開發。生產。__
我們是全球生命科學產業的領導供應商,提供研究、生物技術開發與生產,以及藥物治療開發與生產的解決方案與服務。
[](https://www.sigmaaldrich.com/TW/zh)
[Sigma-Aldrich® 溶液](https://www.sigmaaldrich.com/TW/zh/life-science/sigma-aldrich)[BioReliance® 解決方案](https://www.sigmaaldrich.com/TW/zh/life-science/bioreliance)[Millipore® 溶液](https://www.sigmaaldrich.com/TW/zh/life-science/millipore)[SAFC® 解決方案](https://www.sigmaaldrich.com/TW/zh/life-science/safc)[Milli-Q® 解決方案](https://www.sigmaaldrich.com/TW/zh/life-science/milliq)[Supelco® 解決方案](https://www.sigmaaldrich.com/TW/zh/life-science/supelco)
© 2026 Merck KGaA, Darmstadt, Germany 和/或其附屬公司。版權所有,包括用於 AI 訓練的文字和資料挖掘以及類似技術。
未經許可,嚴禁複製本網站的任何資料。
[網站使用條款](https://www.sigmaaldrich.com/TW/zh/life-science/legal/site-use-terms)|[隱私權政策](https://www.sigmaaldrich.com/TW/zh/life-science/legal/privacy-statement)|[一般銷售條款](https://www.sigmaaldrich.com/TW/zh/life-science/legal/terms-and-conditions)|[版權同意書](https://www.sigmaaldrich.com/TW/zh/life-science/legal/copyright-consent)|[網站地圖](https://www.sigmaaldrich.com/TW/zh/site-map)
An unknown error has occured.