RAD165

radiello Cartridge Adsorbents

for sampling Aldehydes, matrix SS net with 2,4-DNPH coated FLORISIL®, pk of 20

NACRES:
NB.24
Pricing and availability is not currently available.

Agency/Method

EPA TO-11A (*Note: This product is not officially specified in the method, it may be suitable for use for the compound(s) listed in the method*)
OSHA 68,85,1007 (*Note: This product is not officially specified in the method, it may be suitable for use for the compound(s) listed in the method*)

packaging

pk of 20

mfr. no.

Radiello

application(s)

air monitoring: suitable

matrix

SS net with 2,4-DNPH coated FLORISIL®

Featured Industry

Environmental
Industrial Hygiene

compatibility

for sampling Aldehydes

Looking for similar products? Visit Product Comparison Guide

General description

A radiello diffusive sampler consists of 3 parts: the diffusive body, the adsorbent tube, and the triangular support plate. For personal air sampling, a vertical adapter can be installed. The adsorbent cartridge is removed from its glass or plastic storage tube and is inserted into the diffusive body. This is then threaded onto the triangular support plate in order to place the sampler in its sampling position.
Several different Radiello cartridge adsorbents are available. Each of which are specific for sampling different classes of compounds. The dimensions for each cartridge are 60 mm L x 4.8 or 5.8 mm D. Each cartridge is designed for one time use with the exception of Radiello thermal desorption (TD) cartridge adsorbents.

Each cartridge arrives in a sealed glass or plastic tube wrapped in a transparent thermally sealed polyethylene (PE) bag. The same sealed tube can be used to store the cartridge after sampling prior to desorption/analysis. A sufficient number of adhesive barcode labels are included with every pack of cartridges for easy tracking of sampling date and time.

Note: To conduct air sampling using the Radiello system, Radiello diffusive bodies and triangular support plates must be ordered (separately) in addition to cartridge adsorbents. Radiello Starter Kits (RADxxxS) include all the necessary parts to complete a sampling.

Application

A radiello cartridge adsorbent packed with carbograph 4 along with PerkinElmer® tube-type adsorbent packed with Tenax® TA may be used in diffusive sampling in a study, done in order to measure the sampling rate variation of four different samplers namely GABIE, 3M 3500, PerkinElmer® TA and radiello 145 diffusive samplers, while being exposed to a low concentration of volatile organic compounds (VOCs) for a long duration (1-14 days).

Legal Information

Florisil is a registered trademark of U.S. Silica Company
PerkinElmer is a registered trademark of PerkinElmer Inc.
Tenax is a registered trademark of Buchem B.V.
radiello is a trademark of Institi Clinici Scientifici Maugeri

WGK Germany

WGK 2

Certificate of Analysis
Certificate of Origin
Passive Sampling of Atmospheric Organic Contaminants
Esteve-Turrillas, F.A., et al.
Comprehensive Sampling and Sample Preperation, 1, 201-222 (2012)
Volatile organic compounds in air
Methods for the Determination of Hazardous Substances, 1-17 (1997)
Evaluation of a diffusive sampler for measurement of carbonyl compounds in air
Uchiyama, S., et al.
Atmospheric Environment, 38 (37), 6319-6326 (2004)
Volatile aldehydes in libraries and archives
Fenech, A., et al.
Atmospheric Environment, 44 (17), 2067-2073 (2010)
Ambient levels and temporal trends of VOCs, including carbonyl compounds, and ozone at Caba?eros National Park border, Spain
Villanueva, F., et al.
Atmospheric Environment, 85, 256-265 (2014)
Articles
Learn about radiello® Diffusive Sampling Aldehydes Applications & Methods.
Read More
Air sampling products for various aldehydes and phenolic compounds, present in common disinfectants and sanitizing agents causing negative health effects on the essential employees
Read More
Learn the how the diffusive air sampler works to see if it’s the right fit for you.
Read More
Protocols
Learn more about radiello air sampler calibration solutions for aldehydes and H2s. We also offer many air sampler calibration kits.
Read More
Learn how to assemble the supporting plate of your radiello air sampler in the lab before the sampling campaign to save time in the field.
Read More
Related Content
Air monitoring is used to measure the level of air pollutants in environmental, industrial, or indoor settings to assess the air quality per standards established by health and regulatory agencies.
Read More
Learn more about the ready-to-use air sampler. It may be advantageous when you prefer not to assemble all of the components on field. It can be purchased as it is or in separate parts to be assembled by the customer.
Read More
Learn about radiello diffusive sampling and why it’s the best option for your air quality needs.
Read More

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service

Social Media

LinkedIn icon
Twitter icon
Facebook Icon
Instagram Icon

MilliporeSigma

Research. Development. Production.

We are a leading supplier to the global Life Science industry with solutions and services for research, biotechnology development and production, and pharmaceutical drug therapy development and production.

© 2021 Merck KGaA, Darmstadt, Germany and/or its affiliates. All Rights Reserved.

Reproduction of any materials from the site is strictly forbidden without permission.