MilliporeSigma
All Photos(1)

Documents

705993

Sigma-Aldrich

3-epi-25-Hydroxyvitamin D3

98% (CP)

Sign Into View Organizational & Contract Pricing

Empirical Formula (Hill Notation):
C27H44O2
CAS Number:
Molecular Weight:
400.64
MDL number:
PubChem Substance ID:
NACRES:
NA.24

Quality Level

assay

98% (CP)

form

powder

technique(s)

mass spectrometry (MS): suitable

color

white to off-white

mass shift

M+3

storage temp.

−20°C

SMILES string

C[C@@]12[C@](CC[C@]2([H])[C@@H](CCCC(C)(O)C)C)([H])/C(CCC1)=C/C=C3C[C@H](O)CCC/3=C

InChI

1S/C27H44O2/c1-19-10-13-23(28)18-22(19)12-11-21-9-7-17-27(5)24(14-15-25(21)27)20(2)8-6-16-26(3,4)29/h11-12,20,23-25,28-29H,1,6-10,13-18H2,2-5H3/b21-11+,22-12-/t20-,23-,24-,25+,27-/m1/s1

InChI key

JWUBBDSIWDLEOM-UEGFJKGBSA-N

Related Categories

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
753149751316705942
3-epi-25-Hydroxyvitamin D3 98% (CP)

705993

3-epi-25-Hydroxyvitamin D3

3-epi-25-Hydroxyvitamin D2 98% (CP)

753149

3-epi-25-Hydroxyvitamin D2

technique(s)

mass spectrometry (MS): suitable

technique(s)

mass spectrometry (MS): suitable

technique(s)

mass spectrometry (MS): suitable

technique(s)

mass spectrometry (MS): suitable

assay

98% (CP)

assay

98% (CP)

assay

≥98% (CP)

assay

96% (CP)

form

powder

form

powder

form

powder

form

powder

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C

storage temp.

−20°C

color

white to off-white

color

white to off-white

color

off-white to beige

color

-

Application

3-epi-25-Hydroxyvitamin D3 is also known as 3-epi-25(OH)D3. It is a metabolite of vitamin D3 formed in the liver. 3-epi-25(OH)D3 is used as a biomarker to determine the status of vitamin D in the body. It can be also employed as an analytical standard to measure the concentration of 3-epi-25(OH)D3 molecules in human serum.

Packaging

This product may be available from bulk stock and can be packaged on demand. For information on pricing, availability and packaging, please contact Stable Isotopes Customer Service.
To best serve customer requests, each order is packaged and shipped on demand approximately 2 weeks after receipt of an order. If you have questions regarding availability and price, please contact the Stable Isotope Customer Service Group at 937-859-1808 (1-800-448-9760 for US & Canada) or email us at isosales@sial.com.

pictograms

Skull and crossbonesHealth hazard

signalword

Danger

Hazard Classifications

Acute Tox. 2 Inhalation - Acute Tox. 3 Dermal - Acute Tox. 3 Oral - STOT RE 1 Oral

Storage Class

6.1A - Combustible, acute toxic Cat. 1 and 2 / very toxic hazardous materials

wgk_germany

WGK 3

flash_point_f

Not applicable

flash_point_c

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Andrzej Slominski et al.
The Journal of clinical endocrinology and metabolism, 98(2), E298-E303 (2013-01-09)
There is no effective treatment for systemic sclerosis and related fibrosing diseases. Recently the action of CYP11A1 on vitamin D(3) was shown to produce biologically active 20S-hydroxyvitamin D [20(OH)D(3)] and 20,23(OH)(2)D(3), 20,22(OH)(2)D(3), and 17,20,23(OH)(3)D(3). Because 20(OH)D(3) is noncalcemic (nontoxic) in
P V Pradeep et al.
Journal of postgraduate medicine, 59(1), 4-8 (2013-03-26)
No single factor can predict the occurrence of post total thyroidectomy (TT) hypocalcemia. This study was conducted to look at various factors usually implicated in post TT clinically significant hypocalcemia (CSH) and to develop a scoring system using a combination
Yosef Dror et al.
The Journal of clinical endocrinology and metabolism, 98(5), 2160-2167 (2013-03-28)
Low serum calcidiol has been associated with multiple comorbidities and mortality but no "safe" range has been found for the upper concentration. We aim to establish the upper threshold of serum calcidiol, beyond which there is an increased risk for
Alex Aregbesola et al.
Journal of epidemiology and community health, 67(6), 533-536 (2013-04-19)
Vitamin D has been suggested to have a role in infection defence and on the immune system. We therefore investigated the effect of serum 25-hydroxyvitamin D₃ (25(OH)D₃) on the risk of incident hospitalised pneumonia in an ageing general population in
Vitamin D assays and the definition of hypovitaminosis D: results from the First International Conference on Controversies in Vitamin D
Sempos CT, et al.
British Journal of Clinical Pharmacology, 84(10), 2194-2207 (2018)

Articles

Novel sample prep technique coupled with the unique selectivity of the Ascentis Express F5 column enables a fast and simplified bioanalytical method for associated vitamin D metabolites.

Using HybridSPE-Phospholipid, Ascentis Express, and Other LC-MS Workflow Components

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service