705993

Sigma-Aldrich

3-epi-25-Hydroxyvitamin D3

98% (CP)

Empirical Formula (Hill Notation):
C27H44O2
CAS Number:
Molecular Weight:
400.64
MDL number:
PubChem Substance ID:
NACRES:
NA.24

Quality Level

assay

98% (CP)

form

powder

application(s)

mass spectrometry (MS): suitable

color

white to off-white

mass shift

M+3

storage temp.

−20°C

SMILES string

C[C@@]12[C@](CC[C@]2([H])[C@@H](CCCC(C)(O)C)C)([H])/C(CCC1)=C/C=C3C[C@H](O)CCC/3=C

InChI

1S/C27H44O2/c1-19-10-13-23(28)18-22(19)12-11-21-9-7-17-27(5)24(14-15-25(21)27)20(2)8-6-16-26(3,4)29/h11-12,20,23-25,28-29H,1,6-10,13-18H2,2-5H3/b21-11+,22-12-/t20-,23-,24-,25+,27-/m1/s1

InChI key

JWUBBDSIWDLEOM-UEGFJKGBSA-N

Related Categories

Application

3-epi-25-Hydroxyvitamin D3 is also known as 3-epi-25(OH)D3. It is a metabolite of vitamin D3 formed in the liver. 3-epi-25(OH)D3 is used as a biomarker to determine the status of vitamin D in the body. It can be also employed as an analytical standard to measure the concentration of 3-epi-25(OH)D3 molecules in human serum.

Packaging

To best serve customer requests, each order is packaged and shipped on demand approximately 2 weeks after receipt of an order. If you have questions regarding availability and price, please contact the Stable Isotope Customer Service Group at 937-859-1808 (1-800-448-9760 for US & Canada) or email us at isosales@sial.com.
This product may be available from bulk stock and can be packaged on demand. For information on pricing, availability and packaging, please contact Stable Isotopes Customer Service.

Pictograms

Skull and crossbonesHealth hazard

Signal Word

Danger

Hazard Statements

RIDADR

UN 2811 6.1 / PGII

WGK Germany

WGK 3

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Certificate of Analysis
Certificate of Origin
Yosef Dror et al.
The Journal of clinical endocrinology and metabolism, 98(5), 2160-2167 (2013-03-28)
Low serum calcidiol has been associated with multiple comorbidities and mortality but no "safe" range has been found for the upper concentration. We aim to establish the upper threshold of serum calcidiol, beyond which there is an increased risk for...
P V Pradeep et al.
Journal of postgraduate medicine, 59(1), 4-8 (2013-03-26)
No single factor can predict the occurrence of post total thyroidectomy (TT) hypocalcemia. This study was conducted to look at various factors usually implicated in post TT clinically significant hypocalcemia (CSH) and to develop a scoring system using a combination...
3-epi-25 hydroxyvitamin D concentrations are not correlated with age in a cohort of infants and adults
Strathmann FG, et al.
Clinica Chimica Acta; International Journal of Clinical Chemistry, 413(1-2), 203-206 (2012)
Alex Aregbesola et al.
Journal of epidemiology and community health, 67(6), 533-536 (2013-04-19)
Vitamin D has been suggested to have a role in infection defence and on the immune system. We therefore investigated the effect of serum 25-hydroxyvitamin D₃ (25(OH)D₃) on the risk of incident hospitalised pneumonia in an ageing general population in...
Qi Wang et al.
The Journal of steroid biochemistry and molecular biology, 135, 43-50 (2013-01-22)
Vitamin D has been known to be closely associated with diabetes and periodontitis while the underlying mechanism has yet to be clarified. The present study aimed to discover the effect of 25-hydroxyvitamin D3 (25-OHD3) on glycemic control and periodontal health...
Articles
Novel sample prep technique coupled with the unique selectivity of the Ascentis Express F5 column enables a fast and simplified bioanalytical method for associated vitamin D metabolites.
Read More
Using HybridSPE-Phospholipid, Ascentis Express, and Other LC-MS Workflow Components
Read More
Improvement in LC/MS Analysis of Vitamin D Metabolites in Serum by Leveraging Column Selectivity and Effective Sample Prep
Read More
This application shows an Ascentis Express F5 provided rapid resolution of the isobaric vitamin D metabolites. MS detection provides the necessary secondary resolution.
Read More
Related Content
The metabolic role and health implications of the various vitamin D isoforms are of current clinical interest. Therefore, it is important to have an analytical method that will resolve all of the known isoforms with necessary sensitivity and specificity
Read More

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service

Social Media

LinkedIn icon
Twitter icon
Facebook Icon
Instagram Icon

MilliporeSigma

Research. Development. Production.

We are a leading supplier to the global Life Science industry with solutions and services for research, biotechnology development and production, and pharmaceutical drug therapy development and production.

© 2021 Merck KGaA, Darmstadt, Germany and/or its affiliates. All Rights Reserved.

Reproduction of any materials from the site is strictly forbidden without permission.