D-073

Supelco

5α-Dihydrotestosterone (DHT) solution

1.0 mg/mL in methanol, ampule of 1 mL, certified reference material, Cerilliant®

Sign Into View Organizational & Contract Pricing

Synonym(s):
5α-Dihydrotestosterone solution, 5-alpha-Dihydrotestosterone, DHT, Dihydrotestosterone, 5α−DHT solution
Empirical Formula (Hill Notation):
C19H30O2
CAS Number:
Molecular Weight:
290.44
MDL number:
PubChem Substance ID:
NACRES:
NA.24

grade

certified reference material

form

liquid

feature

Snap-N-Spike®/Snap-N-Shoot®

packaging

ampule of 1 mL

manufacturer/tradename

Cerilliant®

concentration

1.0 mg/mL in methanol

technique(s)

gas chromatography (GC): suitable
liquid chromatography (LC): suitable

application(s)

clinical testing
clinical testing

format

single component solution

storage temp.

−70°C

SMILES string

C[C@]12CC[C@H]3[C@@H](CC[C@H]4CC(=O)CC[C@]34C)[C@@H]1CC[C@@H]2O

InChI

1S/C19H30O2/c1-18-9-7-13(20)11-12(18)3-4-14-15-5-6-17(21)19(15,2)10-8-16(14)18/h12,14-17,21H,3-11H2,1-2H3/t12-,14-,15-,16-,17-,18-,19-/m0/s1

InChI key

NVKAWKQGWWIWPM-ABEVXSGRSA-N

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
D-077T-046M-906
form

liquid

form

liquid

form

liquid

form

liquid

packaging

ampule of 1 mL

packaging

ampule of 1 mL

packaging

ampule of 1 mL

packaging

ampule of 1 mL

manufacturer/tradename

Cerilliant®

manufacturer/tradename

Cerilliant®

manufacturer/tradename

Cerilliant®

manufacturer/tradename

Cerilliant®

concentration

1.0 mg/mL in methanol

concentration

100 μg/mL in methanol

concentration

100 μg/mL in acetonitrile

concentration

1.0 mg/mL in 1,2-dimethoxyethane

technique(s)

gas chromatography (GC): suitable, liquid chromatography (LC): suitable

technique(s)

gas chromatography (GC): suitable, liquid chromatography (LC): suitable

technique(s)

gas chromatography (GC): suitable, liquid chromatography (LC): suitable

technique(s)

gas chromatography (GC): suitable, liquid chromatography (LC): suitable

General description

This Certified Spiking Solution® is suitable for GC/MS and LC/MS applications from clinical and diagnostic testing and endocrinology to sports testing.

5α-Dihydrotestosterone (DHT) is a steroid hormone and metabolite of the natural androgen, testosterone, formed by the action of NADPH-dependent enzyme 5α-reductase. It has been implicated in a broad range of diseases from male pattern baldness to benign prostatic hyperplasia and prostate cancer. As an anabolic steroid, DHT has also been used as a performance-enhancing drug to promote muscle growth.

Application

The Certified Reference Material (CRM) in solution can also be used as follows:
  • Simultaneous analysis of testosterone and 5α-dihydrotestosterone using a benchtop gas chromatograph-mass spectrophotometer (GC-MS) in human serum samples
  • Liquid chromatography-electrospray ionization-tandem mass spectrometric (LC/ESI-MS/MS) determination of testosterone and 5α-dihydrotestosterone following their proton affinitive derivatization using picolinic acid and its analogs
  • Determination of testosterone and 5α-dihydrotestosterone in plasma and testis samples of fathead minnow by a gas chromatography-tandem mass spectrometric (GC-MS/MS) method
  • Multi-residue screening of epitestosterone, testosterone, 5α-dihydrotestosterone, dehydroepiandrosterone, androsterone, and etiocholanolone in urine samples by high-resolution full scan-electrospray ionization-liquid chromatography (HR-FS-ESI-LC) combined with quadrupole orbitrap mass spectrometer (Q/Orbitrap MS) following requirements of World Antidoping Agency (WADA)
  • Quantitative analysis of nine hydroxy-androgens and their conjugates by a stable isotope dilution liquid chromatography-electrospray ionization-tandem mass spectrometry (SID-LC-ESI-MS/MS) based method following their derivatization using picolinic acid

Features and Benefits

  • Fully characterized under ISO/IEC 17025 and ISO 17034 accreditation
  • Accompanied with a comprehensive Certificate of Analysis (CoA) with data on stability, homogeneity, accuracy of concentration, uncertainty, and traceability
  • Rigorously tested through real-time stability studies to ensure accuracy and shelf life
  • Gravimetrically prepared using qualified precision balances to ensure minimal uncertainty
  • Flame sealed under argon into ampoules for long-term shelf life
  • Offered in a convenient, DEA-exempt format to improve laboratory efficiency

Legal Information

CERILLIANT is a registered trademark of Merck KGaA, Darmstadt, Germany
CERTIFIED SPIKING SOLUTION is a registered trademark of Cerilliant Corporation
Snap-N-Shoot is a registered trademark of Cerilliant Corporation
Snap-N-Spike is a registered trademark of Merck KGaA, Darmstadt, Germany

related product

Product No.
Description
Pricing

Signal Word

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 3 Inhalation - Acute Tox. 3 Oral - Flam. Liq. 2 - STOT SE 1

Storage Class Code

3 - Flammable liquids

WGK

WGK 2

Flash Point(F)

49.5 °F - closed cup

Flash Point(C)

9.7 °C - closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 1

1 of 1

Testosterone solution 1.0 mg/mL in 1,2-dimethoxyethane, drug standard

Supelco

T5411

Testosterone solution

Paula M Marchetti et al.
Annals of clinical biochemistry, 50(Pt 2), 95-107 (2013-02-23)
Dihydrotestosterone (DHT) is the most potent natural androgen in humans. There has been an increasing interest in this androgen and its role in the development of primary and secondary sexual characteristics as well as its potential roles in diseases ranging
Julia Johansson et al.
PloS one, 8(1), e54357-e54357 (2013-01-26)
In rats with dihydrotestosterone (DHT)-induced polycystic ovary syndrome (PCOS), repeated low-frequency electrical stimulation of acupuncture needles restores whole-body insulin sensitivity measured by euglycemic hyperinsulinemic clamp. We hypothesized that electrical stimulation causing muscle contractions and manual stimulation causing needle sensation have
Angel On Kei Chan et al.
Clinical chemistry, 59(5), 798-806 (2013-03-21)
5α-Reductase 2 deficiency (5ARD) is a known cause of 46,XY disorders of sex development (DSD). Traditionally, the diagnosis relies on dihydrotestosterone (DHT) measurement, but the results are often equivocal, potentially leading to misdiagnosis. We reviewed alternative approaches for diagnosis of
Francesca Argellati et al.
Anticancer research, 33(3), 815-820 (2013-03-14)
To investigate periostin (POSTN) expression in the LNCaP cell line. Our LNCaP strain did not constitutively express the POSTN gene. Through cell transfection with a cloning vector, we developed an LNCaP cell line that stably expressed POSTN. LNCaP wild-type and
Jee In Kim et al.
American journal of physiology. Renal physiology, 305(1), F61-F70 (2013-05-10)
Male gender and the male hormone testosterone increase susceptibility to kidney ischemia and reperfusion (I/R) injury, which is associated with inflammatory responses. Possible involvement of histone deacetylase (HDAC) in inflammatory responses has been suggested. We investigated the gender-specific role of

Articles

This application note describes an accurate and sensitive, Supel™ Swift HLB DPX Tips based analysis of a total of 9 steroids (cortisone, cortisol, 11-deoxycortisol, androstenedione, testosterone, dehydroepiandrosterone, 5α-dihydrotestosterone, 17α-hydroxyprogesterone, and progesterone) in blood serum samples using two different standards (UTAK and NIST).

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service