Skip to Content
MilliporeSigma

Skip To

1.06469

Sodium hydroxide

pellets for analysis (max. 0.02% K) EMSURE® ACS,Reag. Ph Eur,ISO

Synonym(s):

Caustic soda

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
1 kg
Check Cart for Availability
$182.00
5 kg
Check Cart for Availability
$514.00
12 kg
Check Cart for Availability
$846.00
50 kg
Check Cart for Availability
$2,420.00

About This Item

Linear Formula:
NaOH
CAS Number:
Molecular Weight:
40.00
NACRES:
NA.21
EC Index Number:
215-185-5
UNSPSC Code:
12352305
MDL number:
Assay:
99-100% (total alkilinity calculated as NaOH)
Form:
pellets
Grade:
ACS reagent

$182.00


Check Cart for Availability
Packaging: HDPE bottle

Request a Bulk Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


grade

ACS reagent

Quality Level

agency

reag. ISO, reag. Ph. Eur.

vapor density

>1 (vs air)

vapor pressure

<18 mmHg ( 20 °C), 3 mmHg ( 37 °C)

product line

EMSURE®

assay

99-100% (total alkilinity calculated as NaOH)

form

pellets

impurities

≤0.0003% Total nitrogen (N)

pH

>14 (20 °C, 100 g/L in H2O)

mp

318 °C (lit.)

solubility

water: 1090 g/L at 20 °C

density

2.13 g/cm3 at 20 °C

anion traces

carbonate (as Na2CO3): ≤0.5%, chloride (Cl-): ≤0.0005%, phosphate (PO43-): ≤0.0005%, silicate (as SiO2): ≤0.001%, sulfate (SO42-): ≤0.0005%

cation traces

Al: ≤0.0005%, As: ≤0.0001%, Ca: ≤0.0005%, Cu: ≤0.0002%, Fe: ≤0.0005%, Hg: ≤0.00001%, K: ≤0.020%, Mg: ≤0.0005%, Ni: ≤0.0005%, Pb: ≤0.0005%, Zn: ≤0.001%, heavy metals (as Ag): ≤0.0005%, heavy metals (as Pb): ≤0.0005%

storage temp.

2-30°C

SMILES string

[OH-].[Na+]

InChI

1S/Na.H2O/h;1H2/q+1;/p-1

InChI key

HEMHJVSKTPXQMS-UHFFFAOYSA-M

Application


  • Biosorbent derived from coffee husk for efficient removal of toxic heavy metals from wastewater.: Researchers developed a biosorbent from coffee husk to remove heavy metals from wastewater. Sodium hydroxide plays a critical role in the chemical activation of the coffee husk, enhancing its adsorption capacity (Quyen et al., 2021).

  • Development of Advanced Chemometric-Assisted Spectrophotometric Methods for the Determination of Cromolyn Sodium and Its Alkaline Degradation Products.: This paper presents advanced spectrophotometric methods for analyzing cromolyn sodium and its degradation products. Sodium hydroxide is used to induce the degradation of cromolyn sodium, allowing for the study of its breakdown products (El Zahar et al., 2020).

  • High resolution and high throughput analytical methods for d-tagatose and process related impurities using capillary electrophoresis.: The study develops capillary electrophoresis methods for analyzing d-tagatose and its impurities. Sodium hydroxide is employed as an electrolyte to enhance the separation and resolution in the electrophoresis process (Surapureddi et al., 2020).

  • Phosphorus in recycling fertilizers - analytical challenges.: This research addresses the analytical challenges in determining phosphorus in recycling fertilizers. Sodium hydroxide is used to adjust the pH of samples, which is crucial for accurate phosphorus quantification (Krüger and Adam, 2017).

Analysis Note

Assay (acidimetric,NaOH): 99 - 100 %
Assay (total alkalinity calc. as NaOH): 99 - 100 %
Identity: passes test
Appearance of solution: passes test
Carbonate (as Na₂CO₃): ≤ 0.5 %
Chloride (Cl): ≤ 0.0005 %
Phosphate (PO₄): ≤ 0.0005 %
Silicate (SiO₂): ≤ 0.001 %
Sulfate (SO₄): ≤ 0.0005 %
Total nitrogen (N): ≤ 0.0003 %
Heavy metals (as Ag): ≤ 0.0005 %
Heavy metals (as Pb): ≤ 0.0005 %
Al (Aluminium): ≤ 0.0005 %
As (Arsenic): ≤ 0.0001 %
Ca (Calcium): ≤ 0.0005 %
Cu (Copper): ≤ 0.0002 %
Fe (Iron): ≤ 0.0005 %
Hg (Mercury): ≤ 0.00001 %
K (Potassium): ≤ 0.020 %
Mg (Magnesium): ≤ 0.0005 %
Ni (Nickel): ≤ 0.0005 %
Pb (Lead): ≤ 0.0005 %
Zn (Zinc): ≤ 0.001 %

Other Notes

Replaces: SX0590; SX0590-20

Legal Information

EMSURE is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
1.37020221465S5881
grade

ACS reagent

grade

-

grade

ACS reagent

grade

reagent grade

assay

99-100% (total alkilinity calculated as NaOH)

assay

≥98.0-100.5% (total alkilinity calculated as NaOH)

assay

≥97.0%

assay

≥98%

agency

reag. ISO, reag. Ph. Eur.

agency

BP, ChP, JP, NF, Ph. Eur.

agency

suitable for DIN 38407-42, suitable for EPA 1621, suitable for EPA 533, suitable for EPA 8327, suitable for EPA OTM-45, suitable for SM 4500 - NH3

agency

suitable for EPA 1621, suitable for SM 4500 - NH3

Quality Level

300

Quality Level

500

Quality Level

200

Quality Level

200

form

pellets

form

pellets, solid

form

pellets

form

pellets (anhydrous)

storage temp.

2-30°C

storage temp.

15-25°C

storage temp.

-

storage temp.

-


Still not finding the right product?

Explore all of our products under Sodium hydroxide


pictograms

Corrosion

signalword

Danger

hcodes

Hazard Classifications

Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1A

wgk

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable

Storage Class

8B - Non-combustible corrosive hazardous materials



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library





Global Trade Item Number

SKUGTIN
106469100004022536077369
106469901204027269677664
106469500004022536077376
106469905004022536077390
106469905204027269952952

Questions

1–4 of 4 Questions  
  1. What's its purity?

    1 answer
    1. The minimum purity specification for this product is 99%. The lot specific purity is listed in the Certificate of Analysis. Please navigate to the ‘DOCUMENTATION’ section of the Product Detail Page to access a Certificate under ‘Certificate of Analysis’ or click the link below:
      https://www.sigmaaldrich.com/product/mm/106469#product-documentation

      Helpful?

  2. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

  4. How does the pellet size of the discontinued product SX0590 compare to the replacement product 106469?

    1 answer
    1. The pellet size for both 106469 and SX0590 is approximately 5 mm, indicating that they are the same size.

      Helpful?

Reviews

No rating value

Active Filters