MilliporeSigma
All Photos(4)

Documents

1.07019

Supelco

Toluene

for analysis EMPARTA® ACS

Sign Into View Organizational & Contract Pricing

Synonym(s):
Toluol, Methylbenzene
Linear Formula:
C6H5CH3
CAS Number:
Molecular Weight:
92.14
Beilstein:
635760
MDL number:
EC Index Number:
203-625-9

grade

ACS reagent

Quality Level

vapor density

3.2 (vs air)

vapor pressure

22 mmHg ( 20 °C)
26 mmHg ( 25 °C)

product line

EMPARTA®

Assay

≥99.5% (GC)

form

liquid

autoignition temp.

997 °F

expl. lim.

7 %

impurities

≤0.0002 meq/g Acidity
≤0.0006 meq/g Alkalinity
≤0.003% Sulfur compounds (as S)
≤0.03% Water

evapn. residue

≤0.001%

color

APHA: ≤10

refractive index

n/D 1.496 (lit.)

kinematic viscosity

0.7 cSt(20 °C)

bp

110-111 °C (lit.)

mp

-93 °C (lit.)

transition temp

flash point 4 °C

density

0.865 g/mL at 25 °C (lit.)

storage temp.

2-30°C

SMILES string

Cc1ccccc1

InChI

1S/C7H8/c1-7-5-3-2-4-6-7/h2-6H,1H3

InChI key

YXFVVABEGXRONW-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Related Categories

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
1.083271.083311.08325
Toluene for analysis EMPARTA® ACS

Supelco

1.07019

Toluene

Toluene for liquid chromatography LiChrosolv®

Supelco

1.08327

Toluene

Toluene for spectroscopy Uvasol®

Supelco

1.08331

Toluene

Toluene for analysis EMSURE® ACS,ISO,Reag. Ph Eur

Supelco

1.08325

Toluene

vapor density

3.2 (vs air)

vapor density

3.2 (vs air)

vapor density

3.2 (vs air)

vapor density

3.2 (vs air)

vapor pressure

22 mmHg ( 20 °C), 26 mmHg ( 25 °C)

vapor pressure

22 mmHg ( 20 °C), 26 mmHg ( 25 °C)

vapor pressure

22 mmHg ( 20 °C), 26 mmHg ( 25 °C)

vapor pressure

22 mmHg ( 20 °C), 26 mmHg ( 25 °C)

assay

≥99.5% (GC)

assay

≥99.9% (GC)

assay

≥99.9% (GC)

assay

≥99.9% (GC)

form

liquid

form

liquid

form

liquid

form

liquid

autoignition temp.

997 °F

autoignition temp.

997 °F

autoignition temp.

997 °F

autoignition temp.

997 °F

Packaging

1.07019.2521: 2.5L, Minimum order quantity: 4

Analysis Note

Purity (GC): ≥ 99.5 %
Identity (IR): conforms
Appearance: clear
Color: ≤ 10 Hazen
Acidity: ≤ 0.0002 meq/g
Alkalinity: ≤ 0.0006 meq/g
Boiling point: 109 - 111 °C
Sulfur compounds (as S): ≤ 0.003 %
Readily carbonizable substances: conforms
Evaporation residue: ≤ 0.001 %
Water: ≤ 0.03 %

Legal Information

EMPARTA is a registered trademark of Merck KGaA, Darmstadt, Germany

Signal Word

Danger

Hazard Classifications

Aquatic Chronic 3 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

Target Organs

Central nervous system

Storage Class Code

3 - Flammable liquids

WGK

WGK 3

Flash Point(F)

39.9 °F

Flash Point(C)

4.4 °C


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 5

1 of 5

Toluene ACS reagent, ≥99.5%

Sigma-Aldrich

179418

Toluene

3-Chloropropiophenone 98%

Sigma-Aldrich

335614

3-Chloropropiophenone

Residual Solvent - Toluene Pharmaceutical Secondary Standard; Certified Reference Material

Supelco

PHR1317

Residual Solvent - Toluene

Toluene Laboratory Reagent, ≥99.3%

Sigma-Aldrich

179965

Toluene

Related Content

Our ergonomic 1 L HDPE bottle for acids, bases, and solvents provide an alternative to glass chemical bottles for lab safety in pouring & handling of hazardous chemicals in the laboratory.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service