Skip to Content
MilliporeSigma

1.08325

Supelco

Toluene

for analysis EMSURE® ACS,ISO,Reag. Ph Eur

Synonym(s):

Toluol, Methylbenzene

Slide 1 of 8
Sign Into View Organizational & Contract Pricing

Select a Size

Pricing and availability is not currently available.

About This Item

Linear Formula:
C6H5CH3
CAS Number:
Molecular Weight:
92.14
Beilstein/REAXYS Number:
635760
MDL number:
UNSPSC Code:
12191501
EC Index Number:
203-625-9
NACRES:
NA.21
Grade:
ACS reagent
Assay:
≥99.9% (GC)
Bp:
110-111 °C (lit.)
Vapor pressure:
22 mmHg ( 20 °C)
26 mmHg ( 25 °C)

Skip To


Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

grade

ACS reagent

Quality Level

agency

reag. ISO
reag. Ph. Eur.

vapor density

3.2 (vs air)

vapor pressure

22 mmHg ( 20 °C)
26 mmHg ( 25 °C)

product line

EMSURE®

assay

≥99.9% (GC)

form

liquid

autoignition temp.

997 °F

expl. lim.

7 %

dilution

(for analytical testing)

impurities

≤0.000002% As (Arsenic)
≤0.0002 meq/g Acidity
≤0.0006 meq/g Alkalinity
≤0.005% Benzene (GC)
≤0.03% Water
≤0.5 ppm Chloride (Cl)
≤1 ppm Sulfate (SO4)

evapn. residue

≤0.0005%

color

clearAPHA: ≤10

refractive index

n/D 1.496 (lit.)

kinematic viscosity

0.7 cSt(20 °C)

bp

110-111 °C (lit.)

mp

-93 °C (lit.)

transition temp

flash point 4 °C

solubility

0.52 g/L

density

0.865 g/mL at 25 °C (lit.)

cation traces

Ag: ≤0.000002%
Al: ≤0.00005%
Au: ≤0.00001%
B: ≤0.000002%
Ba: ≤0.00001%
Be: ≤0.000002%
Bi: ≤0.00001%
Ca: ≤0.00005%
Cd: ≤0.000005%
Co: ≤0.000002%
Cr: ≤0.000002%
Cu: ≤0.000002%
Fe: ≤0.00001%
In: ≤0.000002%
Li: ≤0.000002%
Mg: ≤0.00001%
Mn: ≤0.000002%
Mo: ≤0.000005%
Ni: ≤0.000002%
Pb: ≤0.00001%
Pt: ≤0.000002%
Sb: ≤0.000002%
Sn: ≤0.00001%
Ti: ≤0.000005%
Tl: ≤0.000005%
V: ≤0.000005%
Zn: ≤0.00001%
Zr: ≤0.000002%

SMILES string

Cc1ccccc1

storage temp.

2-30°C

InChI

1S/C7H8/c1-7-5-3-2-4-6-7/h2-6H,1H3

InChI key

YXFVVABEGXRONW-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
1.08389PHR13111.00849
assay

≥99.9% (GC)

assay

≥99.8% (GC)

assay

-

assay

≥99.8% (GC)

grade

ACS reagent

grade

-

grade

certified reference material, pharmaceutical secondary standard

grade

-

Quality Level

300

Quality Level

100

Quality Level

300

Quality Level

100

technique(s)

titration: suitable

technique(s)

gas chromatography (GC): suitable

technique(s)

HPLC: suitable, gas chromatography (GC): suitable

technique(s)

GC/MS: suitable, gas chromatography (GC): suitable

solubility

0.52 g/L

solubility

-

solubility

-

solubility

0.52 g/L

form

liquid

form

liquid

form

-

form

liquid

General description

EMSURE grade solvents are suitable for a broad spectrum of classical lab applications, and are frequently used in regulated and highly demanding lab applications. EMSURE provides worldwide best and most extensive product specifications. We declare our EMSURE range to be in compliance with the ACS, with the reagent part of the European Pharmacopoeia (Reag. Ph Eur) and also with the ISO standards.

Application


  • Toluene Detection in Biological Samples Using SPME-GC-MS.: This research presents a method for detecting toluene in biological samples using solid-phase microextraction combined with gas chromatography-mass spectrometry (SPME-GC-MS). The method provides high sensitivity and accuracy, making it suitable for biological monitoring of toluene exposure (Suh et al., 2015).

  • Adsorption Characteristics of Toluene on Metal-Organic Frameworks.: This paper explores the adsorption characteristics of toluene on various metal-organic frameworks (MOFs). The study identifies the most efficient MOFs for toluene adsorption, offering insights for industrial applications in air purification (Zhang et al., 2019).

Other Notes

Discover EMSURE - to be more than sure!
Explore various lab safety accessories and equipment for safe handling of solvents to increase your safety level from the first usage.

Legal Information

EMSURE is a registered trademark of Merck KGaA, Darmstadt, Germany

accessory

Product No.
Description
Pricing

signalword

Danger

Hazard Classifications

Aquatic Chronic 3 - Asp. Tox. 1 - Flam. Liq. 2 - Repr. 2 - Skin Irrit. 2 - STOT RE 2 Inhalation - STOT SE 3

target_organs

Central nervous system

Storage Class

3 - Flammable liquids

wgk_germany

WGK 3

flash_point_f

39.9 °F - closed cup

flash_point_c

4.4 °C - closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Protocols

Summary application report for analysis of moisture in Crude oil

Related Content

Our ergonomic 1 L HDPE bottle for acids, bases, and solvents provide an alternative to glass chemical bottles for lab safety in pouring & handling of hazardous chemicals in the laboratory.

See All

Questions

1–3 of 3 Questions  
  1. How can I determine the shelf life / expiration / retest date of this product?

    1 answer
    1. If this product has an expiration or retest date, it will be shown on the Certificate of Analysis (COA, CofA). If there is no retest or expiration date listed on the product's COA, we do not have suitable stability data to determine a shelf life. For these products, the only date on the COA will be the release date; a retest, expiration, or use-by-date will not be displayed.
      For all products, we recommend handling per defined conditions as printed in our product literature and website product descriptions. We recommend that products should be routinely inspected by customers to ensure they perform as expected.
      For products without retest or expiration dates, our standard warranty of 1 year from the date of shipment is applicable.
      For more information, please refer to the Product Dating Information document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/418/501/product-dating-information-06-25-mk.pdf

      Helpful?

  2. What is this toluene intended for? Is there toluene, acetone and isopropyl alcohol without chlorine intended for determining organic chlorine in crude oil according to ASTM D4929 by titration?

    1 answer
    1. The product is a research grade solvent. It is not tested for Chlorine content, nor is it guaranteed to be suitable for use in ASTM D4929 testing.
      To seek a product tested for Chlorine content or for suitability for a given ASTM method, please search our website for products by name, then click the product number of interest to view the specification sheet.

      Helpful?

  3. How is shipping temperature determined? And how is it related to the product storage temperature?

    1 answer
    1. Products may be shipped at a different temperature than the recommended long-term storage temperature. If the product quality is sensitive to short-term exposure to conditions other than the recommended long-term storage, it will be shipped on wet or dry-ice. If the product quality is NOT affected by short-term exposure to conditions other than the recommended long-term storage, it will be shipped at ambient temperature. As shipping routes are configured for minimum transit times, shipping at ambient temperature helps control shipping costs for our customers. For more information, please refer to the Storage and Transport Conditions document: https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/marketing/global/documents/316/622/storage-transport-conditions-mk.pdf

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service