Recommended Products
Quality Level
form
solid
IVD
for in vitro diagnostic use
pH
6.0-7.0
bulk density
520 kg/m3
εmax
1200-1400 at 648-651 nm in methanol at 0.0005%
650-850 at 521-524 nm in methanol at 0.0005%
application(s)
diagnostic assay manufacturing
hematology
histology
storage temp.
2-30°C
Related Categories
General description
Wright′s eosin methylene blue - for microscopy staining dye, is a defined mixture of the dyes C.I. 52015 and C.I. 45380 for hematological staining procedures and is used in conjunction with eosin Y. The Wright′s eosin methylene blue solution can be used for analysis and diagnostics in the whole blood differentiation. The staining of the nuclei is due of the molecular interaction of the Eosin Y dye and a complex of Azur B with DNA. Both dyes assemble to an Eosin Y - Azur B-DNA complex and the intensity of the resulting stain depends on the content of Azur B and the ratio of Azur B : Eosin Y. Furthermore, the resulting stain can vary depending on the influence of fixation, staining times, pH-value of the solutions or buffer substances. For more details, please see instructions for use (IFU). This product is registered as IVD and CE marked. For more details, please see instructions for use (IFU). The IFU can be downloaded from this webpage.
Analysis Note
Identity (UV/VIS-Spectrum): passes test
pH-value (0,01 %; methanol 50 %): 6.0 - 7.0
Absorption maximum λ 1 (Methanol): 648 - 651 nm
Absorption maximum λ 2 (Methanol): 521 - 524 nm
Spec. Absorptivity A 1%/1cm
- λ1max; 0.0005 %; methanol; calculated on dried substance:
1200 - 1400
- λ2max; 0.0005 %; methanol; calculated on dried substance: 650 - 850
TLC-Test: passes test
Loss on drying (105 °C): ≤ 10 %
Suitability for microscopy: passes test
pH-value (0,01 %; methanol 50 %): 6.0 - 7.0
Absorption maximum λ 1 (Methanol): 648 - 651 nm
Absorption maximum λ 2 (Methanol): 521 - 524 nm
Spec. Absorptivity A 1%/1cm
- λ1max; 0.0005 %; methanol; calculated on dried substance:
1200 - 1400
- λ2max; 0.0005 %; methanol; calculated on dried substance: 650 - 850
TLC-Test: passes test
Loss on drying (105 °C): ≤ 10 %
Suitability for microscopy: passes test
signalword
Warning
hcodes
Hazard Classifications
Eye Irrit. 2 - Skin Sens. 1
Storage Class
11 - Combustible Solids
wgk_germany
WGK 3
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service