Spectroquant®

Quality Level

analyte functional class(es)

chemical oxygen demand (COD)

specific analyte(s)

ammonium, nitrogen

technique(s)

photometry: suitable

detection method

photometric (ammonium, COD and nitrogen)

format

multi-component solution

storage temp.

15-25°C

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
1.147381.146761.14675
CombiCheck 50 photometric, Spectroquant®

Supelco

1.14695

CombiCheck 50

CombiCheck 80 photometric, Spectroquant®

Supelco

1.14738

CombiCheck 80

CombiCheck 10 photometric, Spectroquant®

Supelco

1.14676

CombiCheck 10

CombiCheck 20 photometric, Spectroquant®

Supelco

1.14675

CombiCheck 20

detection method

photometric (ammonium, COD and nitrogen)

detection method

photometric (COD, nitrate and phosphorus)

detection method

photometric (ammonium, chloride, CSB, nitrate, phosphorus and sulfate)

detection method

photometric (ammonium, chloride, CSB, nitrate, phosphorus and sulfate)

Quality Level

100

Quality Level

100

Quality Level

100

Quality Level

100

product line

Spectroquant®

product line

Spectroquant®

product line

Spectroquant®

product line

Spectroquant®

analyte functional class(es)

chemical oxygen demand (COD)

analyte functional class(es)

chemical oxygen demand (COD)

analyte functional class(es)

chemical oxygen demand (COD)

analyte functional class(es)

chemical oxygen demand (COD)

specific analyte(s)

ammonium, nitrogen

specific analyte(s)

nitrate, phosphate

specific analyte(s)

ammonium, chloride, nitrate, phosphate, sulfate

specific analyte(s)

ammonium, chloride, nitrate, phosphate, sulfate

General description

This Spectroquant® CombiCheck 50 is a high-quality laboratory solution used for internal quality control and method-controlling purposes.

These Spectroquant® standard solutions perfectly complement our ready-to-use test kits and photometers within the Spectroquant® portfolio and are ideal for validating international norm methods described in e.g., ISO, EN, APHA, and EPA.

Please visit the Reference Material Quality Grade website to find a comprehensive overview of our different grades of standards.

Application

CombiCheck 50 can be used to check the photometric measurement system (reagents, measurement device, handling) and the mode of working.

Features and Benefits

  • Manufactured and tested in DIN EN ISO 9001:2008 accredited laboratory
  • The solution is pre-diluted to a concentration that falls into the range of our Spectroquant® test kits. This eliminates the need for dilution prior to analysis and hence avoids a common source of error
  • Ready-to-use diluted reference materials (RMs) along with expanded measurement uncertainty ensure absolute precision
  • Accompanied with a certificate of analysis (COA) detailing the certified values, including uncertainty and expiry date
  • Directly traceable to standard reference materials (SRM) from the National Institute of Standards and Technology (NIST) or to United States Pharmacopeia (USP)
  • Reliable and reproducible results

Analysis Note

Standard Solution Reagent R-1:

Ammonium: 1.00 ± 0.10 mg/L NH4-N
COD: 20/0 ± 4 mg/L COD
Nitrogen: 5.0 ± 0.7 mg/L N

Addition Solution Reagent R-2 (Spike sample):

Ammonium: 1.00 ± 0.10 mg/L NH4-N
COD: 10.0 ± 3.0 mg/L COD
Nitrogen: 3.0 ± 0.5 mg/L N

Legal Information

SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

12 - Non Combustible Liquids

WGK

nwg

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service