1.14774

Supelco

Nitrite Test

colorimetric, 0.1-10 mg/L (NO2-), for use with MCOLORTEST®

Sign Into View Organizational & Contract Pricing

specific analyte(s)

nitrite

Quality Level

measuring range

0.1-10 mg/L (NO2-)

compatibility

for use with MCOLORTEST®

detection method

colorimetric

storage temp.

15-25°C

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
1.144081.169731.10022
vibrant-m

1.14774

Nitrite Test

vibrant-m

1.14408

Nitrite Test

vibrant-m

1.16973

Nitrite Test

vibrant-m

1.10022

Nitrite Test

specific analyte(s)

nitrite

specific analyte(s)

nitrite

specific analyte(s)

nitrite

specific analyte(s)

nitrite

measuring range

0.1-10 mg/L (NO2-)

measuring range

0.0015-0.030 mg/L (NO2-N), 0.005-0.10 mg/L (NO2-)

measuring range

0.5-25.0 mg/L (NO2-)

measuring range

0.1-3 g/L (NO2-)

microbialanalysis
microbialanalysis

microbialanalysis
microbialanalysis

microbialanalysis
microbialanalysis

microbialanalysis
microbialanalysis

compatibility

for use with MCOLORTEST®

compatibility

for use with MQUANT®

compatibility

RQflex® 10 Plus, RQflex® 20, for use with REFLECTOQUANT®

compatibility

for use with MQuant® StripScan App

storage temp.

15-25°C

storage temp.

15-25°C

storage temp.

2-8°C

storage temp.

2-8°C

General description

Method: colorimetric with color-disk comparator 0.1 - 0.2 - 0.4 - 0.6 - 1.0 - 1.8 - 3.0 - 6.0 - 10 mg/l NO MQuant®
Nitrite is naturally present in soil, water and food, and regularly testing its concentration is essential for many applications. With the MQuant® Nitrite test (formally MColortest®) Nitrites can be closely monitored in drinking and ground water as well as in process, waste, or aquarium water. The test can be used in:
  • Groundwater and surface water, seawater
  • Drinking water and mineral water
  • Waters from aquaculture
  • Boiler and boiler feed water, cooling water
  • Wastewater and electroplating wastewater
  • Food after appropriate sample pretreatment
  • Soils after appropriate sample pretreatment

Method
In acidic solution nitrite ions react with sulfanilic acid to form a diazonium salt, which in turn reacts with N-(1-naphthyl)ethylenediamine dihydrochloride to form a red-violet azo dye. The nitrite concentration is measured semiquantitatively by visual comparison of the color of the measurement solution with the color fields of a color disk. The test evaluates the color reaction based on the transmitted light method. So even turbid and colored water samples can be analyzed without further preparation.
The color disk is made of very durable, lightfast plastic, thus suitable for industrial areas and wet environments.

Legal Information

MCOLORTEST is a registered trademark of Merck KGaA, Darmstadt, Germany
MQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

pictograms

Exclamation mark

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1

Storage Class

11 - Combustible Solids

wgk_germany

WGK 2


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 7

1 of 7

Ammonium Test colorimetric, 0.5-10 mg/L (NH4+), for use with MQUANT®

Supelco

1.11117

Ammonium Test

Nitrite Test colorimetric, 2-80 mg/L (NO2-), MQuant®

Supelco

1.10007

Nitrite Test

Alkalinity Test titrimetric, for use with MQUANT®

Supelco

1.11109

Alkalinity Test

Nitrate Test photometric, 0.3-30.0 mg/L (NO3-N), Spectroquant®

Supelco

1.01842

Nitrate Test

Ammonium Test colorimetric, 0.2-5 mg/L (NH4+), for use with MQUANT®

Supelco

1.08024

Ammonium Test

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service