While most HPLC columns feature 10.32 threaded end fittings, some may have different types and sizes of fittings. Given the wide variety of HPLC systems, it is not possible to guarantee with complete certainty that a specific HPLC system utilizes 10.32 fittings. Furthermore, even within a single type of fitting, such as 10.32, there are short, standard, and extended versions of the nut and ferrule. Hence, it is advisable to consult the instrument manual to determine the correct fitting type and size.
Select a Size
| Pack Size | SKU | Availability | Price |
|---|---|---|---|
| 1 unit | Check Cart for Availability | $816.00 |
About This Item
$816.00
Product Name
Purospher® STAR NH2 (5 µm), L × I.D. 150 mm x 4.6 mm LiChroCART™ HPLC cartridge, manuCART™ holder required for use
material
stainless steel column
Quality Level
agency
suitable for USP L8
product line
Purospher®
feature
endcapped: no
packaging
1 ea of
extent of labeling
3.5% Carbon loading
parameter
250 bar pressure, 60 °C max. temp.
technique(s)
HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium)
column L × I.D.
15 cm × 4.6 mm
surface area
330 m2/g
matrix
fully porous particle
matrix active group
NH2 bonding phase
particle size
5 μm
pore size
120 Å pore size
operating pH range
2-7.5
separation technique
hydrophilic interaction (HILIC), normal phase, reversed phase
storage temp.
no temp limit
General description
Application
Features and Benefits
- Ultra-pure silica (99.999%)
- Low silanol activity
- Reproducible results from run-to-run and batch-to-batch
Analysis Note
Theoretical Plates (N/m) (2-Nitrotoluene): ≥ 50000
Symmetry (2-Nitrotoluene): 0.8 - 1.4
Capacity factor (2-Nitrotoluene): ≤ 3.0
Legal Information
1 of 1
This Item | |||
|---|---|---|---|
| separation technique hydrophilic interaction (HILIC), reversed phase, normal phase | separation technique hydrophilic interaction (HILIC), normal phase, reversed phase | separation technique hydrophilic interaction (HILIC), normal phase, reversed phase | separation technique hydrophilic interaction (HILIC), normal phase, reversed phase |
| matrix active group NH2 bonding phase | matrix active group NH2 bonding phase | matrix active group NH2 bonding phase | matrix active group NH2 bonding phase |
| particle size 5 μm | particle size 5 μm | particle size 5 μm | particle size 5 μm |
| matrix fully porous particle | matrix fully porous particle | matrix fully porous particle | matrix fully porous particle |
| product line Purospher® | product line Purospher® | product line Purospher® | product line Purospher® |
| technique(s) HPLC: suitable, mass spectrometry (MS): suitable (Low - Medium), LC/MS: suitable | technique(s) HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium) | technique(s) HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium) | technique(s) HPLC: suitable, LC/MS: suitable, mass spectrometry (MS): suitable (Low - Medium) |
Still not finding the right product?
Explore all of our products under Purospher® STAR NH2 (5 µm)
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
Global Trade Item Number
| SKU | GTIN |
|---|---|
| 1502470001 | 04022536752655 |
-
Is the product Purospher® STAR NH2 (5 µm) LiChroCART® 150-4.6 column (catalog number 1.50247.0001 or 48219-474) compatible with the Agilent 1260 HPLC system?
1 answer-
Helpful?
-