AX1303

Supelco

Ammonium Hydroxide

Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

Synonym(s):
Ammonia aqueous, Ammonium hydroxide solution, Ammonia water, Ammonia Solution
Linear Formula:
NH4OH
CAS Number:
Molecular Weight:
35.05
Beilstein/REAXYS Number:
3587154
MDL number:

storage conditions

Store at room temperature.

Quality Level

vapor pressure

635 hPa ( 20 °C)

expl. lim.

27 %

pH

>12 (20 °C in H2O, strongly alkaline)

bp

32 °C

mp

-72 °C

density

0.9 g/mL at 25 °C (lit.)

shipped in

ambient

storage temp.

room temp

SMILES string

[NH4+].[OH-]

InChI

1S/H3N.H2O/h1H3;1H2

InChI key

VHUUQVKOLVNVRT-UHFFFAOYSA-N

Packaging

2.5 l in Glas bottle pre packed
500 ml in Glas bottle pre packed
145 l in Plastic barrel

Application

AX1303-53 is for Canada only
AX1303P-5, AX1303-57 and AX1303-75 are packaged in poly coated glass bottles
Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

Analysis Note

Aluminum (Al): 0.3ppm max
Appearance: Passes test
Assay (as NH3): 28.0-30.0%
Calcium (Ca): 0.3ppm max
Carbon dioxide (CO2): 0.002% max
Chloride (Cl): 0.5ppm max
Chromium (Cr): 0.3ppm max
Copper (Cu): 0.1ppm max
Gold (Au): 0.3ppm max
Heavy metals (as Pb): 0.5ppm max
Iron (Fe): 0.2ppm max
Lead (Pb): 0.2ppm max
Magnesium (Mg): 0.3ppm max
Manganese (Mn): 0.2ppm max
Nickel (Ni): 0.1ppm max
Nitrate (NO3): 2ppm max
Phosphate (PO4): 2ppm max
Potassium (K): 0.3ppm max
Residue after ignition: 0.002% max
Sodium (Na): 0.3ppm max
Substances reducing permanganate: To pass test
Sulfate (SO4): 2ppm max
Tin (Sn): 0.3ppm max
Titanium (Ti): 0.3ppm max
Zinc (Zn): 0.3ppm max

Signal Word

Danger

Hazard Statements

hazcat

Aquatic Acute 1 - Aquatic Chronic 2 - Eye Dam. 1 - Skin Corr. 1 - STOT SE 3

Target Organs

Respiratory system

storage_class_code

8B - Non-combustible, corrosive hazardous materials

WGK Germany

WGK 2

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable

Certificate of Analysis

Certificate of Origin

Articles
Shown here is the chiral separation of amphetamine enantiomers under MS-compatible conditions on Astec CHIROBIOTIC® V2 after extraction from urine using Supel™-Select SCX SPE 96-well plates. The highest grade mobile phase solvents and additives were used to supply low background interference and low particulate contaminants for robust, trouble-free operation. Cerilliant CRMs provided reliable identification and quantification.
Read More
Protocols
LC/MS Analysis of Methamphetamine Enantiomers on Astec® CHIROBIOTIC® V2 in Urine after SPE using Supel™-Select SCX
Read More

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service