Skip To
material
PureFlex™ polyethylene bag (film)
polyester body
silicone septum (platinum-cured)
silicone tubing
stainless steel body (ASTM® 316 L)
Quality Level
agency
according to ISO ISO 11137
meets USP 88 Biological Reactivity
sterility
sterile; β-irradiated
product line
NovaSeptum® GO
feature
autoclavable: no
parameter
-20-50 °C temp. range (-4-122 °F)
0.50 bar max. pressure (7.25 psi)
impurities
<2.15 bacterial endotoxins (LAL test, EU/device)
fitting
female Luer-Lok® outlet
male Luer-Lok® outlet
application(s)
cell therapy
gene therapy
life science and biopharma
mAb
ophthalmics
parenterals
pharma/biopharma processes
sterile sampling
viral therapy
storage temp.
room temp
1 of 4
This Item | DEM461-90020 | DEM461-90005 | DEM714-10100 |
|---|---|---|---|
| fitting female Luer-Lok® outlet, male Luer-Lok® outlet | fitting female Luer-Lok® outlet, male Luer-Lok® outlet | fitting female Luer-Lok® outlet, male Luer-Lok® outlet | fitting female Luer-Lok® outlet (3-piece), male Luer-Lok® outlet (3-piece) |
| feature autoclavable: no | feature autoclavable: no | feature autoclavable: no | feature autoclavable: no |
| material PureFlex™ polyethylene bag (film), silicone septum (platinum-cured), stainless steel body (ASTM® 316 L), polyester body, silicone tubing | material polycarbonate syringe (Fluid contact layer), polyester body, silicone septum (platinum-cured), silicone syringe (Fluid contact layer, medical silicone fluid), silicone syringe (Fluid contact layer, platinum-cured), silicone tubing, stainless steel body (ASTM® 316 L) | material polycarbonate syringe (Fluid contact layer), polyester body, silicone septum (platinum-cured), silicone syringe (Fluid contact layer, medical silicone fluid), silicone syringe (Fluid contact layer, platinum-cured), silicone tubing, stainless steel body (ASTM® 316 L) | material PureFlex™ polyethylene bag (film), TPE tubing (Thermoplastic elastomer), polyester body, silicone septum (platinum-cured), stainless steel body (ASTM® 316 L) |
| product line NovaSeptum® GO | product line NovaSeptum® GO | product line NovaSeptum® GO | product line NovaSeptum® GO |
| agency according to ISO ISO 11137 | agency meets USP 88 Biological Reactivity | agency according to ISO ISO 11137, meets USP 88 Biological Reactivity | agency according to ISO ISO 11137, meets USP 88 Biological Reactivity |
| sterility sterile; β-irradiated | sterility sterile; β-irradiated | sterility sterile; β-irradiated | sterility sterile; β-irradiated |
General description
Application
Packaging
Preparation Note
Units are integrity tested at regular intervals during manufacturing.
Aqueous extraction contains < 2.15 EU per device as determined using the Limulus Amebocyte Lysate (LAL) test.
Other Notes
- Septum: Platinum-cured silicone; Body: Polyester; Cannula: ASTM® 316 L Stainless steel
- Drainage bag: Polyethylene film (PureFlex film)
- Fluid contact layer (syringe): Polycarbonate,
platinum-cured silicone, medical silicone fluid
- Tubing: Silicone
- Outlet Tubing: Female and male Luer-Lok®
Legal Information
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service