Glycerol

Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

Sign Into View Organizational & Contract Pricing

Synonym(s):
Glycerin, 1, 1,2,3-Propanetriol, Glycerin
Linear Formula:
HOCH2CH(OH)CH2OH
CAS Number:
Molecular Weight:
92.09
Beilstein:
635685
MDL number:
EC Index Number:
200-289-5

Agency

meets USP/NF

Quality Level

vapor density

3.1 (vs air)

vapor pressure

<1 mmHg ( 20 °C)

Assay

≥99.5% (GC)

form

liquid

autoignition temp.

698 °F

technique(s)

electrophoresis: suitable

impurities

≤0.003% Chlorinated compounds (as Cl)
≤0.05% Fatty acid esters (as butyric acid)
≤0.5% Water
≤2 ppm Heavy metals (as Pb)

ign. residue

≤0.005%

color

APHA: ≤10

refractive index

n20/D 1.474 (lit.)

pH

5 (20 °C, 100 g/L in H2O)

bp

182 °C/20 mmHg (lit.)

mp

20 °C (lit.)

transition temp

flash point 199 °C

density

1.25 g/mL (lit.)

anion traces

sulfate (SO42-): ≤0.001%

shipped in

ambient

storage temp.

room temp

SMILES string

OCC(O)CO

InChI

1S/C3H8O3/c4-1-3(6)2-5/h3-6H,1-2H2

InChI key

PEDCQBHIVMGVHV-UHFFFAOYSA-N

Looking for similar products? Visit Product Comparison Guide

Related Categories

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
GX0190G7757G7893
Glycerol Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

Supelco

GX0185

Glycerol

Glycerol

Supelco

GX0190

Glycerol

Glycerol ReagentPlus&#174;, &#8805;99.0% (GC)

Sigma-Aldrich

G7757

Glycerol

Glycerol ACS reagent, &#8805;99.5%

Sigma-Aldrich

G7893

Glycerol

vapor pressure

<1 mmHg ( 20 °C)

vapor pressure

<1 mmHg ( 20 °C)

vapor pressure

<1 mmHg ( 20 °C)

vapor pressure

<1 mmHg ( 20 °C)

assay

≥99.5% (GC)

assay

≥95%

assay

≥99.0% (GC)

assay

≥99.5%

form

liquid

form

liquid

form

viscous liquid

form

viscous liquid

autoignition temp.

698 °F

autoignition temp.

698 °F

autoignition temp.

698 °F

autoignition temp.

698 °F

technique(s)

electrophoresis: suitable

technique(s)

electrophoresis: suitable

technique(s)

electrophoresis: suitable

technique(s)

electrophoresis: suitable

Application

Glycerol is used both in sample preparation and gel formation for polyacrylamide gel electrophoresis. Glycerol (5-10%) increases the density of a sample so that the sample will layer at the bottom of a gel′s sample well. Glycerol is also used to aid in casting gradient gels and as a protein stabilizer and storage buffer component.
Meets ACS Specifications, Meets Reagent Specifications for testing USP/NF monographs GR ACS

Analysis Note

Acrolein and glucose: To pass test
Assay (GC): 99.5% min
Chlorinated compounds (as Cl): 0.003% max
Color (APHA): 10 max
Fatty acid esters (as butyric acid): 0.05% max
Form: Clear liquid
Heavy metals (as Pb): 2ppm max
Infrared Spectrum: Conforms to standard
Neutrality: To pass test
Residue after ignition: 0.005% max
Substances darkened by sulfuric acid: To pass test
Sulfate (SO4): 0.001% max
Water (H2O): 0.5% max

Storage Class Code

10 - Combustible liquids

WGK

WGK 1

Flash Point(F)

390.2 °F - Pensky-Martens closed cup

Flash Point(C)

199 °C - Pensky-Martens closed cup


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Customers Also Viewed

Slide 1 of 8

1 of 8

Glycerol ReagentPlus&#174;, &#8805;99.0% (GC)

Sigma-Aldrich

G7757

Glycerol

Glycerol anhydrous for synthesis

Sigma-Aldrich

8.18709

Glycerol

Glycerin meets USP testing specifications

Sigma-Aldrich

G2289

Glycerin

Glycerol solution 83.5-89.5% (T)

Sigma-Aldrich

49781

Glycerol solution

Glycerol Molecular Biology Grade

Millipore

356352-M

Glycerol

Glycerol FCC, FG

Sigma-Aldrich

W252506

Glycerol

Glycerin United States Pharmacopeia (USP) Reference Standard

USP

1295607

Glycerin

Glycerol analytical standard

Supelco

77067

Glycerol

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service