Skip to Content
MilliporeSigma

HNPMAG-35K

MILLIPLEX® Human Neuropeptide Magnetic Bead Panel - Neuroscience Multiplex Assay

The analytes available for this multiplex kit are: α-MSH, β-Endorphin, Neurotensin, Oxytocin, Substance P.

Synonym(s):

Human Neuroscience Protein Multiplex Assay, Luminex® Human Neuroscience Panel, Millipore Human Neuroscience Immunoassay

Sign In to View Organizational & Contract Pricing

About This Item

UNSPSC Code:
12161503
eCl@ss:
32161000
NACRES:
NA.84

To order a Milliplex® kit, please search for your analyte of interest.

Skip To

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist

Quality Level

species reactivity

human

manufacturer/tradename

Milliplex®

assay range

accuracy: 98-118%
(Spike Recovery)

sensitivity: 11-479 pg/mL
(MinDC+2SD)

standard curve range: 27-20,000 pg/mL
(α-MSH)

standard curve range: 41-30,000 pg/mL
(Neurotensin)

standard curve range: 55-40,000 pg/mL
(Oxytocin)

standard curve range: 69-50,000 pg/mL
(β-Endorphine)

standard curve range: 7-5,000 pg/mL
(Substance P)

technique(s)

multiplexing: suitable

detection method

fluorometric (Luminex xMAP)

shipped in

wet ice

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
HNDG3MAG-36KHNABTMAG-68KAPOMAG-62K
species reactivity

human

species reactivity

human

species reactivity

human

species reactivity

human

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

assay range

accuracy: 98-118%
(Spike Recovery), standard curve range: 27-20,000 pg/mL
(α-MSH), standard curve range: 55-40,000 pg/mL
(Oxytocin), standard curve range: 7-5,000 pg/mL
(Substance P), sensitivity: 11-479 pg/mL
(MinDC+2SD), standard curve range: 69-50,000 pg/mL
(β-Endorphine), standard curve range: 41-30,000 pg/mL
(Neurotensin)

assay range

accuracy: 108%
(RANTES), accuracy: 108%
(sICAM-1), accuracy: 111%
(Cathepsin D), accuracy: 123%
(PDGF-AA), accuracy: 137%
(PDGF-AB/BB), standard curve range: 2-10,000 pg/mL
(RANTES), standard curve range: 2.4-10,000 pg/mL
(BDNF), standard curve range: 2.4-10,000 pg/mL
(PAI-1 (total)), standard curve range: 2.4-10,000 pg/mL
(PDGF-AA), standard curve range: 24-100,000 pg/mL
(Cathepsin D), standard curve range: 24-100,000 pg/mL
(MPO), standard curve range: 24-100,000 pg/mL
(NCAM), standard curve range: 24-100,000 pg/mL
(PDGF-AB/BB), standard curve range: 24-100,000 pg/mL
(sICAM-1), standard curve range: 61-250,000 pg/mL
(sVCAM-1)

assay range

accuracy: 109%
(Spike recovery for Aβ1-42), accuracy: 91%
(Spike recovery for pTau181), accuracy: 98%
(Spike recovery for tTau), sensitivity: 1.5 pg/mL
(pTau181; MinDC+2SD), sensitivity: 10.2 pg/mL
(A?1-40; MinDC+2SD), sensitivity: 14.2 pg/mL
(tTau; MinDC+2SD), sensitivity: 2.5 pg/mL
(A?1-42; MinDC+2SD), standard curve range: 0.7-500 pg/mL
(pTau181), standard curve range: 11-8000 pg/mL
(tTau), standard curve range: 2-2000 pg/mL
(Aβ1-42), standard curve range: 21-15000 pg/mL
(Aβ1-40), inter-assay cv: <15%
intra-assay cv: <10%

assay range

accuracy: 85%
(Apo E), accuracy: 86%
(Apo AI), accuracy: 89%
(Apo CIII), accuracy: 92%
(Apo B), sensitivity: 1.00 ng/mL
(Apo AII), sensitivity: 1.22 ng/mL
(Apo CII), sensitivity: 1.42 ng/mL
(Apo E), sensitivity: 1.48 ng/mL
(Apo AI), sensitivity: 1.71 ng/mL
(Apo CIII), sensitivity: 4.84 ng/mL
(Apo B)

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex xMAP)

General description

The central nervous system is a complex environment consisting of billions of neurons and glial support cells. These neurons use chemical signals to communicate information. Neuropeptides are neuronal signaling molecules secreted by the central and peripheral nervous systems, influencing a broad spectrum of biological functions including the regulation of metabolism, reproduction, immunity, and behavior. Understanding the role of neuropeptides in the pathogenesis of devastating neuronal diseases and behavioral disorders is fundamental. While it is understood that accurate measurement of neuropeptides is important, conventional methods, including RIAs and ELISAs, are not able to simultaneously measure multiple neuropeptides with small sample volume. MILLIPLEX® Human Neuropeptide Bead Panel is a 5-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma, cerebrospinal fluid (CSF), tissue/cell lysate, and culture supernatant samples: α-Melanocyte Stimulating Hormone (α-MSH), β-Endorphin, Neurotensin, Oxytocin, and Substance P.

The MILLIPLEX® Human Neuropeptide Bead Panel is to be used for the simultaneous quantification of the following 5 analytes in any combination: α-MSH, β-Endorphin, Neurotensin, Oxytocin, and Substance P. This kit may be used for the analysis of all or any combination of the above analytes in tissue/cell lysate, culture supernatant samples, and cerebrospinal fluid (CSF). Serum or plasma samples may also be used and will need to be extracted. An important note about this conversion panel is that the samples may be extracted using either the acetonitrile precipitation technique or the Waters 96-well HLB extraction plate. Please refer to the protocol for more information on both methods. The necessary components to perform the extractions are not included with the kit.

Panel Type: Neuroscience

Application

  • Analytes: α-MSH, β-Endorphin, Neurotensin, Oxytocin, Substance P
  • Note that this is a competitive assay.
  • Recommended Sample type: serum, plasma, tissue culture supernatant, or CSF
  • Recommended Sample dilution: extracted serum or plasma or neat CSF or culture supernatant
  • Assay Run Time: Overnight
  • Research Category: Neuroscience

Biochem/physiol Actions

There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.

Features and Benefits

Design your multiplex kit by choosing available analytes within this panel.

Packaging

Everything you need in a single kit.

Preparation Note

Recommended storage for kit components is 2 - 8°C.

Other Notes

Human Neuropeptide Standard, 1 vial, lyophilized

Human Neuropeptide Quality Control 1, 1 vial, lyophilized

Human Neuropeptide Quality Control 2, 1 vial, lyophilized

Assay Buffer, 2 bottles, 30 mL ea.

Wash Buffer, 10X (0.05% Proclin), 2 bottles, 30 mL ea

Human Neuropeptide Primary Antibodies, 1 bottle, 3.5 mL

Human Neuropeptide Detection Antibodies, 1 bottle, 5.5 mL

Human Neuropeptide Matrix Solution, 1 bottle, 1.5 mL

Human Neuropeptide Antibody-Immobilized Magnetic Beads, 20X, 200 uL ea

Streptavidin-Phycoerythrin, 1 bottle, 5.5 mL

Mixing Bottle, 1 bottle

Sample Plate, 96 well format, 1 plate with 2 Foil Plate Sealers
Sensitivity: Refer to kit protocol for sensitivities of individual biomarkers.

Legal Information

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

pictograms

Skull and crossbonesEnvironment

signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1

Storage Class

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

wgk_germany

WGK 3


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library

Immediate effects of spinal manipulation on nitric oxide, substance P and pain perception.
Molina-Ortega, F; Lomas-Vega, R; Hita-Contreras, F; Plaza Manzano, G; Achalandabaso et al.
Manual therapy null
Marco Barbariga et al.
Investigative ophthalmology & visual science, 59(3), 1305-1312 (2018-04-07)
The purpose of this study was to investigate the role of substance P (SP) in patients affected with corneal neovascularization (CNV) and in three different Tac1-knockout (KO) murine models of CNV. SP levels in tears were measured with a multiplex
Ann M Manzardo et al.
American journal of medical genetics. Part A, 170(9), 2328-2333 (2016-08-16)
Prader-Willi syndrome (PWS) is a rare genetic neurodevelopmental disorder associated with maladaptive social behavior, hyperphagia and morbid obesity. Orexin A is a hypothalamic neuropeptide important as a homeostatic regulator of feeding behavior and in energy metabolism through actions in the
Emmanuel Bäckryd et al.
Pain medicine (Malden, Mass.), 15(1), 111-119 (2013-10-15)
Pain medicine still lacks mechanism-specific biomarkers to guide diagnosis and treatment, and defective top-down modulation is an important factor in the pathophysiology of chronic pain conditions. Using modern analytical tools and advanced multivariate statistical analysis, the aim of this study
Olga V Roschina et al.
Journal of clinical medicine, 10(23) (2021-12-11)
The neuropeptides β-endorphin and oxytocin are released into the bloodstream as hormones from the pituitary gland but also have an important function as neuroregulators in the forebrain. The blood levels of both polypeptides have been shown to reflect depressive symptoms.

Related Content

Neuroscience multiplex assays, such as MILLIPLEX® multiplex assays, enable simultaneous measurement of neuroscience-related biomarkers to gain a better picture of neurodegenerative diseases, neurological disorders, and neuropeptide/neurohormone signaling.

Learn how multiplex detection of Alzheimer’s disease biomarkers, using the MILLIPLEX® Human Amyloid Beta and Tau Magnetic Bead Panel, allows for a different perspective on neurodegenerative disease research.

Encuentre los inmunoanálisis que permiten explorar las citocinas que intervienen en la neuroinmunología y la neuroinflamación, así como los biomarcadores de enfermedades neurodegenerativas.

Find immunoassays to explore neuroimmunology and neuroinflammation cytokines and neurodegenerative disease biomarkers.

See All

Questions

  1. Can reagents from two or more Milliplex kits be combined and run in a single plate if the bead regions do not overlap and if the samples use the same dilution factor?

    1 answer
    1. The kits cannot be combined after purchase because the detection antibodies are provided at a 1X concentration. Combining reagents would dilute out the detection antibody cocktails, impacting the signal and sensitivity. Additionally, there is a risk of cross-reactivity, and the matrix conditions may vary depending on the kit. We do offer an SPR program for combining panels and can review requests prior to the purchase of the kits.

      Helpful?

Reviews

No rating value

Active Filters

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service