KMP2G003FF1

Milligard® PES 1.2/0.2 μm nominal, Opticap® Small Scale 300 Capsule

Fittings 3/4 in. Sanitary Flange Inlet and Outlet, Method Gamma-compatible or Autoclavable

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice

About This Item

UNSPSC Code:
23151806
Pricing and availability is not currently available.
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Segment

material

polyester support, polyethersulfone membrane, polypropylene housing (Gamma Stable), silicone O-ring

product line

Opticap®

feature

hydrophilic

technique(s)

bioburden reduction: suitable

L × W

11.7 cm (5.08 in.) × 6.4 cm (2.5 in.)

filtration area

0.032 m2 (0.34 ft2)

matrix

Milligard® PES

pore size

1.2/0.2 μm (nominal)

fitting

inlet and outlet for 19 mm (3/4 in.) (Sanitary Flange)

General description

Milligard® PES 1.2/0.2 μm nominal filters are designed for effective bioburden control and reliable particulate removal from a broad range of fluid streams. When used standalone for non critical applications, these membrane-based filters typically remove Ͱ 6 log Brevundimonas diminuta. When used upstream of sterilizing-grade filters or other unit operations, they improve processing efficiency.
Milligard® PES filters are supported by the Emprove® Program which consolidates product specific testing, quality and regulatory information to simplify compliance needs.

Application

Bioburden Reduction

Features and Benefits

  • Fast flow and high throughput
  • Validated bioburden reduction
  • Predictable scalability from small-scale to production-size devices
  • High thermal stability: compatible with steam-in-place and autoclave sterilization methods
  • Single-use, gamma-ready formats
  • Caustic stable

Packaging

PE Bag

Other Notes

Directions for Use


Organism Retention: Microorganism
Mode of Action: Filtration (size exclusion)
Application: BioProcessing
Intended Use: Reduction or removal of microorganism/bioburden
Instructions for Use: Please refer to Opticap® Small Scale 300 Capsule, XL, XLT and T-line Capsules User Guide
Storage Statement: Store in dry location
Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

Legal Information

Emprove is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Filters are designed, developed and manufactured in accordance with a Quality Management System approved by an accredited registering body to the ISO 9001 Quality Systems Standard. Certificate of Quality is available online for all filters.

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
KMP2G003HH1KMP2G2STT1KMP2G2TTT1
pore size

1.2/0.2 μm (nominal)

pore size

1.2/0.2 μm (nominal)

pore size

1.2/0.2 μm pore size (nominal)

pore size

1.2/0.2 μm pore size (nominal)

product line

Opticap®

product line

Opticap®

product line

Opticap®

product line

Opticap®

technique(s)

bioburden reduction: suitable

technique(s)

bioburden reduction: suitable

technique(s)

prefiltration: suitable

technique(s)

prefiltration: suitable

filtration area

0.032 m2 (0.34 ft2)

filtration area

0.032 m2 (0.34 ft2)

filtration area

1.2 m2 (12.8 ft2)

filtration area

1.2 m2 (12.8 ft2)

matrix

Milligard® PES

matrix

Milligard® PES

matrix

Milligard® PES

matrix

Milligard® PES

material

polyester support, polypropylene housing (Gamma Stable), polyethersulfone membrane, silicone O-ring

material

polyester support, polyethersulfone membrane, polypropylene housing (Gamma Stable), silicone O-ring

material

polyester support, polyethersulfone membrane (Hydrophilic (PES)), polypropylene housing (Gamma Stable), silicone O-ring

material

polyester support, polyethersulfone membrane (Hydrophilic (PES)), polypropylene housing (Gamma Stable), silicone O-ring


Still not finding the right product?




Stay compliant with GMP using the Emprove® Program

Accelerate qualification, maintain compliance, and save time with Emprove® Dossiers.

Download Dossiers

Note: you will be brought to EmproveSuite.com. Your username and password are separate from SigmaAldrich.com and may differ.

Register for free and access Emprove® Dossiers within minutes. Upgrade your subscription plan to unlock advanced and customized content in the Emprove® Suite

Not finding what you are looking for? Visit the Emprove® Program Help page.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Articles

Prefilters can be used throughout bioprocessing to remove to remove particulates, improve quality and protect sterilizing filters and downstream unit operations.

Related Content

PrefilterFamilyGuide





Questions

Reviews

No rating value

Active Filters