MAGPMAG-24K
MILLIPLEX® Mouse Angiogenesis/Growth Factor Magnetic Bead Panel - Cancer Multiplex Assay
for the simultaneous quantification of multiple analytes
About This Item
Skip To
Quality Level
species reactivity
mouse
manufacturer/tradename
Milliplex®
assay range
accuracy: 90-104%
standard curve range: 1-1,000 pg/mL
(Endothelin-1)
standard curve range: 137-100,000 pg/mL
(Follistatin)
standard curve range: 137-100,000 pg/mL
(HGF)
standard curve range: 137-100,000 pg/mL
(SDF-1)
standard curve range: 14-10,000 pg/mL
(IL-1b)
standard curve range: 14-10,000 pg/mL
(Leptin)
standard curve range: 14-10,000 pg/mL
(MIP-1α)
standard curve range: 14-10,000 pg/mL
(sALK-1)
standard curve range: 14-10,000 pg/mL
(sCD31/ PECAM-1)
standard curve range: 27-20,000 pg/mL
(Angiopoietin-2)
standard curve range: 27-20,000 pg/mL
(EGF)
standard curve range: 27-20,000 pg/mL
(Endoglin)
standard curve range: 27-20,000 pg/mL
(MCP-1)
standard curve range: 27-20,000 pg/mL
(VEGF-C)
standard curve range: 3-2,000 pg/mL
(PLGF-2)
standard curve range: 6-4,000 pg/mL
(TNFα)
standard curve range: 6-4,000 pg/mL
(VEGF-A)
standard curve range: 69-50,000 pg/mL
(FGF-2/FGF-basic)
standard curve range: 69-50,000 pg/mL
(Prolactin)
standard curve range: 69-50,000 pg/mL
(VEGF-D)
standard curve range: 69-50,000 pg/mL
(sFasL)
standard curve range: 7-5,000 pg/mL
(Amphiregulin)
standard curve range: 7-5,000 pg/mL
(Betacellulin)
standard curve range: 7-5,000 pg/mL
(G-CSF)
standard curve range: 7-5,000 pg/mL
(IL-17A)
standard curve range: 7-5,000 pg/mL
(IL-6)
standard curve range: 7-5,000 pg/mL
(KC/CXCL1)
technique(s)
multiplexing: suitable
detection method
fluorometric (Luminex xMAP)
shipped in
wet ice
1 of 4
This Item | HAGP1MAG-12K | MAP2MAG-76K | HCMBMAG-22K |
|---|---|---|---|
| species reactivity mouse | species reactivity human | species reactivity mouse | species reactivity human |
| manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® | manufacturer/tradename Milliplex® |
| assay range accuracy: 90-104%, standard curve range: 137-100,000 pg/mL | assay range accuracy: 42-131%, standard curve range: 1.4-1,000 pg/mL | assay range accuracy: 99.2-128.2%, sensitivity: 0.001-7.495 ng/mL, standard curve range: 0.001-0.5 ng/mL | assay range accuracy: 70-105%, standard curve range: 0,019-80 ng/mL |
| Quality Level 200 | Quality Level 200 | Quality Level 200 | Quality Level 200 |
| shipped in wet ice | shipped in wet ice | shipped in wet ice | shipped in wet ice |
| detection method fluorometric (Luminex xMAP) | detection method fluorometric (Luminex xMAP) | detection method fluorometric (Luminex xMAP) | detection method fluorometric (Luminex xMAP) |
General description
MILLIPLEX® Mouse Angiogenesis//Growth Factor Panel, is a 24-plex (for serum/plasma) or 27-plex (for cell culture) kit to be used for the simultaneous quantification of the following analytes: Angiopoietin-2, G-CSF, sFasL, sAlk-1, Amphiregulin, Leptin, IL-1b, Betacellulin, EGF, IL-6, Endoglin, Endothelin-1, FGF-2, Follistatin, HGF, PECAM-1, IL-17, PLGF-2, KC, MCP-1, Prolactin, MIP-1a, SDF-1, VEGF-C, VEGF-D, VEGF-A, and TNFα. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.
The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.
Panel Type: Circulating Cancer
Application
- Analytes: sALK-1, Amphiregulin, Angiopoietin-2, Betacellulin, sCD31/sPECAM-1, EGF, Endoglin, Endothelin-1, sFasL, FGF-2 (FGF-basic), Follistatin (FST), G-CSF, HGF, IL-1β, IL-6, IL-17A (CTLA8), KC (GRO/CINC-1/CXCL1), Leptin, MCP-1 (CCL2), MIP-1α (CCL3), Placental Growth Factor 2 (PLGF-2), Prolactin, SDF-1 (CXCL12), TNF-α, VEGF-A, VEGF-C, VEGF-D
- NOTE: Angiopoeitin-2, Betacellulin, and PECAM-1 should not be run in serum/plasma samples
- Recommended Sample Type: Mouse serum, plasma or tissue/cell culture supernatants or lysates
- Recommended Sample Dilution: 25 μL per well of diluted serum or plasma; cell/tissue culture samples may require diltion in appropriate control medium
- Assay Run Time: Overnight (16-20 hours) at 2-8°C
- Research Category: Cancer
Biochem/physiol Actions
Features and Benefits
Packaging
Preparation Note
Other Notes
Legal Information
Disclaimer
signalword
Danger
Hazard Classifications
Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2
target_organs
Respiratory Tract
Storage Class
10 - Combustible liquids
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Related Content
Get even more out of your samples with this Luminex® technology-based mouse cytokine assay – the MILLIPLEX® Mouse Cytokine Expanded Panel 1.
The angiogenesis pathway is complex with many targets to analyze. Simultaneous quantification of multiple markers, with the MILLIPLEX® Human Angiogenesis/Growth Factor Panel 1, saves valuable resources. See how this panel was used to correlate angiogenesis biomarkers with early metastatic progression in NSCLC.
Cancer biomarker detection through MILLIPLEX® multiplex cancer assays can accelerate studies of tumorigenic processes helping advance cancer research.
-
Does the Mouse Angiogenesis panel (MAGPMAG-24K) cross-react with rat samples?
1 answer-
Helpful?
-
-
Can the Wash Buffer substitute Sheath Fluid or Drive at the end of a Milliplex assay to resuspend the beads?
1 answer-
The plate can be used in Wash Buffer, but it may not be as stable, and it should be read within a few hours. If you need to store the plate overnight, it should be in Sheath Fluid or Drive Fluid.