description

The MILLIPLEX® MAP Mouse Cardiovascular Disease Panel 2 is used for the simultaneous quantification of any of the following analytes in serum, plasma, or culture supernatant samples: sCD40L, CXCL16, Endocan-1, Follistatin, LIGHT, Oncostatin M, PlGF-2, Troponin I, Troponin T.

Quality Level

species reactivity

mouse

manufacturer/tradename

Milliplex®

assay range

accuracy: 84-106%
standard curve range: 137-100,000 pg/mL
(CD40L)

standard curve range: 14-10,000 pg/mL
(Endocan-1)

standard curve range: 274-200,000 pg/mL
(Follistatin)

standard curve range: 34-25,000 pg/mL
(CXCL16, Oncostatin M)

standard curve range: 4-3,000 pg/mL
(PIGF-2)

standard curve range: 686-500,000 pg/mL
(LIGHT, Troponin I)

standard curve range: 69-50,000 pg/mL
(Troponin T)

inter-assay cv: <20%
intra-assay cv: <10%

technique(s)

multiplexing: suitable

detection method

fluorometric (Luminex xMAP)

shipped in

wet ice

Compare Similar Items

View Full Comparison

1 of 4

This Item
MCVD1MAG-77KHCVD1MAG-67KHCVD4MAG-67K
species reactivity

mouse

species reactivity

mouse

species reactivity

human

species reactivity

human

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

assay range

accuracy: 84-106%, standard curve range: 137-100,000 pg/mL
(CD40L), standard curve range: 14-10,000 pg/mL
(Endocan-1), standard curve range: 274-200,000 pg/mL
(Follistatin), standard curve range: 34-25,000 pg/mL
(CXCL16, Oncostatin M), standard curve range: 4-3,000 pg/mL
(PIGF-2), standard curve range: 686-500,000 pg/mL
(LIGHT, Troponin I), standard curve range: 69-50,000 pg/mL
(Troponin T), inter-assay cv: <20%
intra-assay cv: <10%

assay range

accuracy: 88-99%, sensitivity: 0.008 ng/mL
(proMMP-9), sensitivity: 0.012 ng/mL
(PAI-1 (total)), sensitivity: 0.012 ng/mL
(Pecam-1), sensitivity: 0.013 ng/mL
(sICAM-1), sensitivity: 0.033 ng/mL
(sE-Selectin), sensitivity: 0.039 ng/mL
(Thrombomodulin), sensitivity: 0.429 ng/mL
(sP-Selectin), standard curve range: 0.007-30 ng/mL
(sICAM-1), standard curve range: 0.012-50 ng/mL
(proMMP-9), standard curve range: 0.018-75 ng/mL
(PAI-1 (total)), standard curve range: 0.024-100 ng/mL
(Pecam-1), standard curve range: 0.024-100 ng/mL
(Thrombomodulin), standard curve range: 0.049-200 ng/mL
(sE-Selectin), standard curve range: 0.439-1800 ng/mL
(sP-Selectin), inter-assay cv: <15%
intra-assay cv: <10%

assay range

accuracy: 100%
(CK-MB), accuracy: 102%
(LIGHT), accuracy: 102%
(Oncostatin (OSM)), accuracy: 103%
(CXCL6/GCP-2), accuracy: 96%
(FABP3), accuracy: 96%
(Placental Growth Factor (PlGF)), accuracy: 97%
(NT proBNP), standard curve range: 137.2-100,000 pg/mL
(FABP3), standard curve range: 2.7-2,000 pg/mL
(Placental Growth Factor (PlGF)), standard curve range: 34.3-25,000 pg/mL
(NT proBNP, CXCL16, Endocan-1 (ESM-1), LIGHT), standard curve range: 6.9-5,000 pg/mL
(CXCL6, Oncostatin (OSM)), standard curve range: 68.6-50,000 pg/mL
(BNP, CK-MB, Troponin I (TnI)), standard curve range: 685.9-500,000 pg/mL
(FABP4), inter-assay cv: <20%
intra-assay cv: <10%

assay range

accuracy: 103%
(Thrombomodulin), accuracy: 104%
(Pentraxin-3 (PTX3)), accuracy: 104%
(Tissue Factor (TF)), accuracy: 106%
(Pecam-1), accuracy: 109%
(sE-Selectin), standard curve range: 0.01-5 ng/mL
(Troponin T (TnT)), standard curve range: 0.04-30 ng/mL
(Follistatin (FST)), standard curve range: 0.14-100 ng/mL
(Pentraxin-3 (PTX3) & Tissue Factor (TF)), standard curve range: 0.27-200 ng/mL
(Pecam-1), standard curve range: 0.34-250 ng/mL
(Thrombomodulin), standard curve range: 2.7-2,000 ng/mL
(sE-Selectin), inter-assay cv: <20%
intra-assay cv: <10%

technique(s)

multiplexing: suitable

technique(s)

multiplexing: suitable

technique(s)

multiplexing: suitable

technique(s)

multiplexing: suitable

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex xMAP)

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

General description

Cardiovascular disease (CVD), particularly atherosclerotic vascular disease, is a leading cause of global mortality, accounting for 30% of all global deaths (WHO). Inflammatory mechanisms play a vital role in the initiation, maintenance, and progression of vascular disease with a strong correlation between inflammatory markers and prognosis in acute and chronic coronary artery disease. Numerous studies have demonstrated an association of obesity and diabetes with cardiovascular risk
factors.

MILLIPLEX® Mouse CVD Panel 2 is a 9 plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma, or tissue culture samples: sCD40L, CXCL16, Endocan-1, Follistatin, LIGHT, Oncostatin M, PlGF-2, Troponin I and Troponin T. This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Cardiovascular

Specificity

Cross Reactivty
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes within a panel.

Application

  • Analytes: sCD40L, CXCL16, Endocan-1 (ESM-1), Follistatin, LIGHT, Oncostatin M (OSM), , Placental Growth Factor 2 (PIGF-2), Troponin I (TnI), Troponin T (TnT)
  • Recommended Sample Type: Mouse serum, plasma, or cell/tissue culture supernatants or lysates
  • Recommended Sample Dilution: 10 μL per well of undiluted serum or plasma; cell/tissue culture supernatants may require dilution in appropriate control medium
  • Assay Run Time: Overnight (16-18 hours) at 2-8°C
  • Research Category: Cardiovascular Disease
  • Research Subcategory: Metabolism

Features and Benefits

Design your multiplex kit by choosing available analytes within this panel.

Packaging

Everything you need in a single kit.

Components

Mouse CVD Panel 2 Standard, 1 vial, lyophilized

Mouse CVD Panel 2 Quality Control 1, 1 vial, lyophilized

Mouse CVD Panel 2 Quality Control 2, 1 vial, lyophilized

Serum Matrix (0.08% Sodium Azide), 1 vial, lyophilized

Assay Buffer, 1 bottle, 30 mL

Bead Diluent, 1 bottle, 4 mL

Wash Buffer, 10X (0.05% Proclin), 2 bottles, 30 mL ea

Mouse CVD Panel 2 Detection Antibodies, 1 bottle, 5.5 mL

Streptavidin-Phycoerythrin, 1 bottle, 5.5 mL

Mixing Bottle, 1 bottle

Sample Plate, 96 well format, 1 plate

2 Foil Plate Sealers

Storage and Stability

Recommended storage for kit components is 2 - 8°C.

Other Notes

Please contact Technical Service for linearity of dilution.
Sensitivity: See kit protocol for individual analytes sensitivities.

Legal Information

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Pictograms

Skull and crossbonesEnvironment

Signal Word

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1

Storage Class Code

6.1C - Combustible, acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

WGK

WGK 3


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

(enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service