MilliporeSigma
All Photos(2)

NHPMHMAG-45K

Millipore

MILLIPLEX® Non-Human Primate Metabolic Magnetic Bead Panel - Metabolism Multiplex Assay

The analytes available for this multiplex kit are: Amylin (Active), C-Peptide, Ghrelin (Active), GIP, Glucagon Like Peptide-1, Glucagon, IL-6, Insulin, Leptin, MCP-1, PP, PYY.

Sign Into View Organizational & Contract Pricing
eCl@ss:
32161000

Quality Level

species reactivity

nonhuman primates

manufacturer/tradename

Milliplex®

assay range

accuracy: 102%
(Ghrelin (Active))

accuracy: 91%
(Insulin)

accuracy: 93%
(GLP-1)

accuracy: 94%
(PP)

accuracy: 98%
(MCP-1)

accuracy: 99%
(Leptin)

sensitivity: 0.6-65.1 pg/mL
standard curve range: 13.7-10,000 pg/mL
(Ghrelin (Active), GLP-1, Glucagon, IL-6, MCP-1, PP, PYY)

standard curve range: 137.2-100,000 pg/mL
(Insulin, Leptin)

standard curve range: 2.7-2,000 pg/mL
(GIP)

standard curve range: 27.4-20,000 pg/mL
(Amylin)

standard curve range: 68.6-50,000 pg/mL
(C-Peptide)

inter-assay cv: <15%
intra-assay cv: <10%

technique(s)

multiplexing: suitable

detection method

fluorometric (Luminex xMAP)

shipped in

wet ice

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
HMHEMAG-34KMMHE-44KHMH3-34K
manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

assay range

accuracy: 102%
(Ghrelin (Active)), accuracy: 91%
(Insulin), accuracy: 93%
(GLP-1), accuracy: 94%
(PP), accuracy: 98%
(MCP-1), accuracy: 99%
(Leptin), sensitivity: 0.6-65.1 pg/mL, standard curve range: 13.7-10,000 pg/mL
(Ghrelin (Active), GLP-1, Glucagon, IL-6, MCP-1, PP, PYY), standard curve range: 137.2-100,000 pg/mL
(Insulin, Leptin), standard curve range: 2.7-2,000 pg/mL
(GIP), standard curve range: 27.4-20,000 pg/mL
(Amylin), standard curve range: 68.6-50,000 pg/mL
(C-Peptide), inter-assay cv: <15%
intra-assay cv: <10%

assay range

accuracy: 101%
(Glucagon), accuracy: 102%
(Leptin), accuracy: 103%
(GIP), accuracy: 103%
(GLP-1 (Total)), accuracy: 105%
(Ghrelin (Active)), accuracy: 106%
(MCP-1), accuracy: 97%
(TNFα), accuracy: 99%
(C-Peptide), sensitivity: 0.5 pg/mL
(MinDC+2SD; TNF?), sensitivity: 1.1 pg/mL
(MinDC+2SD; GIP), sensitivity: 13 pg/mL
(MinDC+2SD; IL-6), sensitivity: 14 pg/mL
(MinDC+2SD; Ghrelin (Active)), sensitivity: 14 pg/mL
(MinDC+2SD; MCP-1), sensitivity: 146 pg/mL
(MinDC+2SD; PYY), sensitivity: 15 pg/mL
(MinDC+2SD; Amylin (Total)), sensitivity: 16 pg/mL
(MinDC+2SD; C-Peptide), sensitivity: 16 pg/mL
(MinDC+2SD; Glucagon), sensitivity: 160 pg/mL
(MinDC+2SD; Insulin), sensitivity: 2.4 pg/mL
(MinDC+2SD; GLP-1 (Active)), sensitivity: 2.9 pg/mL
(MinDC+2SD; PP), sensitivity: 28 pg/mL
(MinDC+2SD; Amylin (Active)), sensitivity: 64 pg/mL
(MinDC+2SD; Leptin), sensitivity: 7.3 pg/mL
(MinDC+2SD; GLP-1 (Total)), standard curve range: 0.69-500 pg/mL
(TNFα), standard curve range: 1.4-1,000 pg/mL
(GIP), standard curve range: 13.7-10,000 pg/mL
(Amylin (Active)), standard curve range: 13.7-10,000 pg/mL
(Amylin (Total)), standard curve range: 13.7-10,000 pg/mL
(Ghrelin (Active)), standard curve range: 13.7-10,000 pg/mL
(Glucagon), standard curve range: 13.7-10,000 pg/mL
(IL-6), standard curve range: 13.7-10,000 pg/mL
(MCP-1), standard curve range: 13.7-10,000 pg/mL
(PYY), standard curve range: 137-100,000 pg/mL
(Insulin), standard curve range: 137-100,000 pg/mL
(Leptin), standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Active)), standard curve range: 2.7-2,000 pg/mL
(GLP-1 (Total)), standard curve range: 2.7-2,000 pg/mL
(PP), standard curve range: 27.4-20,000 pg/mL
(C-Peptide), inter-assay cv: <15%
intra-assay cv: <10%
(C-Peptide), inter-assay cv: <15%
intra-assay cv: <10%
(GIP), inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Active)), inter-assay cv: <15%
intra-assay cv: <10%
(GLP-1 (Total)), inter-assay cv: <15%
intra-assay cv: <10%
(Ghrelin (Active)), inter-assay cv: <15%
intra-assay cv: <10%
(Glucagon), inter-assay cv: <15%
intra-assay cv: <10%
(IL-6), inter-assay cv: <15%
intra-assay cv: <10%
(Insulin), inter-assay cv: <15%
intra-assay cv: <10%
(Leptin), inter-assay cv: <15%
intra-assay cv: <10%
(MCP-1), inter-assay cv: <15%
intra-assay cv: <10%
(PP), inter-assay cv: <15%
intra-assay cv: <10%
(PYY), inter-assay cv: <15%
intra-assay cv: <10%
(TNFα), inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Active)), inter-assay cv: <20%
intra-assay cv: <10%
(Amylin (Total))

assay range

-

assay range

-

technique(s)

multiplexing: suitable

technique(s)

multiplexing: suitable

technique(s)

multiplexing: suitable

technique(s)

multiplexing: suitable

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex® xMAP®)

detection method

fluorometric (Luminex® xMAP®)

shipped in

wet ice

shipped in

wet ice

shipped in

-

shipped in

-

General description

Metabolic syndrome is a cluster of conditions, including increased blood pressure, elevated insulin levels, abnormal cholesterol levels and excess body fat around the waist. Key features of metabolic syndrome include insulin resistance, glucose intolerance, hypertension, dyslipidemia, and central obesity.

MILLIPLEX® Non-Human Primate Metabolic Panel is a 12-plex kit to be used for the simultaneous quantification of any or all of the following analytes in serum, plasma, tissue/cell lysate and culture supernatant samples: Amylin (active), C-Peptide, Ghrelin (active), GIP (total), GLP-1 (active), Glucagon, IL-6, Insulin, Leptin, MCP-1/CCL2, Pancreatic Polypeptide (PP), and PYY (total). This kit uses a 96-well format, contains a lyophilized standard cocktail, two internal assay quality controls and can measure up to 38 samples in duplicate.

The Luminex® xMAP® platform uses a magnetic bead immunoassay format for ideal speed and sensitivity to quantitate multiple analytes simultaneously, dramatically improving productivity while conserving valuable sample volume.

Panel Type: Metabolism

Specificity

Cross Reactivty
There was no or negligible cross-reactivity between the antibodies for an analyte and any of the other analytes in this panel.

Application

  • Analytes: Amylin (Active), C-Peptide, Ghrelin (Active), GIP (Total), Glucagon Like Peptide-1 (GLP-1) (Active), Glucagon, IL-6, Insulin, Leptin, MCP-1 (CCL2), Pancreatic Polypeptide (PP), PYY (Total)
  • NOTE: When measuring specific analytes, protease inhibitors should be added to blood samples upon collection: DPPIV inhibitor for GLP-1; Protease Inhibitor Cocktail for Amylin; Aprotinin for Glucagon; Serine Protease Inhibitor for Ghrelin (Active)
  • Recommended Sample Type: Non-human primate serum, plasma, cell/tissue culture supernatants and lysates.
  • Recommended Sample Dilution: 25 μL per well of undiluted serum or plasma; cell/tissue culture samples may require dilution with an appropriate control medium.
  • Assay Run Time: Overnight (18-20 hours) at 2-8°C.
  • Research Category: Metabolism
  • Research Category: Metabolic Diseases, Obesity

Features and Benefits

Design your multiplex kit by choosing available analytes within this panel.

Packaging

Everything you need in a single kit.

Storage and Stability

Recommended storage for kit components is 2 - 8°C.

Legal Information

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.

Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Julia L Nugent et al.
iScience, 24(12), 103421-103421 (2021-12-09)
The obesity epidemic significantly contributes to overall morbidity and mortality. Bariatric surgery is the gold standard treatment for obesity and metabolic dysfunction, yet the mechanisms by which it exerts metabolic benefit remain unclear. Here, we demonstrate a model of vertical
Eliete Dalla Corte Frantz et al.
PloS one, 8(7), e67192-e67192 (2013-07-31)
The associations between obesity, hypertension and diabetes are well established, and the renin-angiotensin system (RAS) may provide a link among them. The effect of RAS inhibition on type 2 diabetes is still unclear; however, RAS seems to play an important

Related Content

Multiplexing Metabolic Syndrome Biomarkers | MILLIPLEX® Assays

Multiplex immunoassays, such as MILLIPLEX® multiplex metabolic assays, are critical in metabolic syndrome research because they provide a full picture of the different conditions related to it, like diabetes and obesity, as well as save time and sample volume.

Multiplexing in Vet Med and Animal Health Research | MILLIPLEX® Assays

Learn the benefits of using biomarker detection multiplex immunoassays for laboratory, companion, and agricultural animal research and explore MILLIPLEX® multiplex assays for veterinary medicine and animal health research.

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service