P2B050V05

Pellicon® 2 Cassette Media: Biomax® 50 kDa

Chemistry: Polyethersulfone (PES) Screen Type: V Device Size: 0.5 m2

Synonym(s):

Pellicon® 2 Cassette Ultrafiltration Module Biomax-50 V 0.5 m2, Pellicon® 2 Cassette Ultrafiltration Biomax® Module

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
1 ea
Check Cart for Availability
$4,270.00

About This Item

UNSPSC Code:
23151806

$4,270.00


Check Cart for Availability

Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Pellicon® 2 Cassette Media: Biomax® 50 kDa, Chemistry: Polyethersulfone (PES) Screen Type: V Device Size: 0.5 m2

Quality Segment

material

polyethersulfone , polypropylene screen, polyurethane adhesive

manufacturer/tradename

Pellicon®

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

technique(s)

analytical sample preparation: suitable, protein purification: suitable

H

2.16 cm (0.85 in.)

L

21 cm (8.3 in.)

W

17.8 cm (7.0 in.)

filtration area

0.5 m2

membrane nominal area

0.5 m2

gravimetric extractables

≤1500 mg/m2

matrix

Biomax®

pore size

50 kDa NMWCO

pH

1-14

General description

The Pellicon® 2 Ultrafiltration BIOMAX 50 Cassette sets the standard in cassette-style tangential flow filtration devices. P2B050V05 was designed with process scale-up and applications development in mind.

Millipore′s BIOMAX 50 polyethersulfone membrane has void-free structures that guard against leakage of solutes through microdefects normally associated with voids beneath the thin skins of conventional UF membranes. These void-free membranes are more permeable, resulting in high-flux with equivalent or superior product retention. These void-free membranes provide the advantages of fast, high yield processing and smaller systems.

The Pellicon® 2 Cassette Ultrafiltration BIOMAX Module feature a filtration area of 0.5 m2 with a pore size of 50 kDa NMWCO.

Application

Concentration, desalting or buffer exchange of:
  • Protein solutions
  • Polysaccharide solutions
  • Virus suspensions


Harvest, washing or clarification of:
  • Cell cultures and lysates
  • Colloidal suspensions
  • Viral cultures

Features and Benefits

  • Type V screen (open channel)
  • Leading-edge void- free membranes to match virtually any separation challenge
  • Short flow path for higher flux and higher resolution separation capability
  • Choice of flow channel configuration providing process optimization capability
  • Predictable, fast, scale-up
  • True linear scalability from laboratory size modules to industrial assemblies for processing thousands of liters
  • Brings higher resolution, improved yields and superior back-pressure resistance
  • Ultracel membranes are composite membranes cast on a microporous substrate for defect-free membranes with superior

Analysis Note

Gravimetric Extractables: after a water flush

Other Notes

Prefiltration Rquirements: 100 µm
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

BIOMAX is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
P2B050C05P2B050A05P2B005V05
matrix

Biomax®

matrix

Biomax®

matrix

Biomax®

matrix

Biomax®

pore size

50 kDa NMWCO

pore size

50 kDa NMWCO

pore size

50 kDa NMWCO

pore size

5 kDa NMWCO

material

polyethersulfone , polyurethane adhesive, polypropylene screen

material

polyethersulfone , polypropylene screen, polyurethane adhesive

material

polyethersulfone , polypropylene screen, polyurethane adhesive

material

polyethersulfone , polypropylene screen, polyurethane adhesive

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward), 5-35 L/min recirculation rate at 0.4 bar (6 psi)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 4-6 L/min recirculation rate at 1.4 bar (20 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

parameter

0.33 bar max. transmembrane pressure (5 psig) (reverse), 5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C (forward)

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®

manufacturer/tradename

Pellicon®


Still not finding the right product?


Storage Class

10 - Combustible liquids

wgk

WGK 2



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

Reviews

No rating value

Active Filters