Skip to Content
MilliporeSigma

Skip To

P2GVPPV05

Pellicon® 2 Cassette Media: Durapore® 0.22 µm

Chemistry: Polyvinylidene Fluoride (PVDF) Screen Type: V Device Size: 0.5 m2

Pellicon® 2 Cassette Media: Durapore® 0.22 µm

Synonym(s):

Pellicon 2 Cassette Filter Module GVPP 0.22 μm V 0.5 m2, Pellicon® 2 Cassette Filter

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
1 ea

Estimated to ship TODAY

$4,210.00

About This Item

eCl@ss:
32031623
UNSPSC Code:
23151806

$4,210.00


Estimated to ship TODAYDetails


Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Product Name

Pellicon® 2 Cassette Media: Durapore® 0.22 µm, Chemistry: Polyvinylidene Fluoride (PVDF) Screen Type: V Device Size: 0.5 m2

Quality Segment

material

PVDF , polypropylene screen, polyurethane adhesive

manufacturer/tradename

Pellicon®

parameter

5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C

technique(s)

analytical sample preparation: suitable, protein purification: suitable

H

2.16 cm (0.85 in.)

L

21 cm (8.3 in.)

W

17.8 cm (7.0 in.)

filtration area

0.5 m2

membrane nominal area

0.5 m2

gravimetric extractables

≤1500 mg/m2

matrix

Durapore®

pore size

0.22 μm nominal pore size, 0.22 μm pore size

pH

2-11

General description

The Pellicon® 2 product line was designed with process scale-up and applications development in mind. The series of devices includes the long established Durapore® hydrophilic PVDF microfiltration membrane, well known for its exceptional combination of high flux, low protein binding and high product recoveries.

This Pellicon® 2 Cassette Filter is a cassette, microfiltration product with a filtration area of 0.5 m2 and a 0.22 μm pore size.

This Pellicon® 2 cassette features a type v screen (open channel) and measures 17.8 cm (W) x 21 cm (L) x 1.5 cm (H).

Features and Benefits

  • Leading-edge void-free membranes to match virtually any separation challenge
  • Short flow path for higher flux and higher resolution separation capability
  • Choice of flow channel configuration providing process optimization capability
  • Predictable, fast, scale-up
  • True linear scalability from laboratory size modules to industrial assemblies for processing thousands of liters

Analysis Note

Gravimetric Extractables: after a water flush

Other Notes

Prefiltration Rquirements: 100 µm
These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
P2GVPPC05P2VVPPV05P2DVPPC05
pore size

0.22 μm nominal pore size, 0.22 μm pore size

pore size

0.22 μm nominal pore size, 0.22 μm pore size

pore size

0.1 μm nominal pore size, 0.1 μm pore size

pore size

0.65 μm nominal pore size, 0.65 μm pore size

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

filtration area

0.5 m2

filtration area

0.5 m2

filtration area

0.5 m2

filtration area

0.5 m2

matrix

Durapore®

matrix

Durapore®

matrix

Durapore®

matrix

Durapore®

material

PVDF , polyurethane adhesive, polypropylene screen

material

PVDF , polypropylene screen, polyurethane adhesive

material

PVDF , polypropylene screen, polyurethane adhesive

material

PVDF , polypropylene screen, polyurethane adhesive

parameter

5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C

parameter

5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C

parameter

5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C

parameter

5-35 L/min recirculation rate at 0.4 bar (6 psi), 7 bar max. transmembrane pressure (100 psig) at 30 °C


Still not finding the right product?


Storage Class

10 - Combustible liquids

wgk

WGK 2



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

Reviews

Active Filters

    • Review 1
    • Votes 0
    5 out of 5 stars.

    Millipore cassettes are the best

    In the field of biopharmaceutical filtration, Millipore cassettes are widely regarded as the benchmark for reliability, high flux performance, effective impurity clearance, and reusability.

    Helpful?