PCC030C01C
Pellicon® Capsule with Ultracel® Membrane
pore size 30 kDa, C Screen, size 0.1 m2 , with AseptiQuik® G connectors
Select a Size
This item is not able to be purchased as a guest user. For further information, please contact us at +1 866 227 3811or
.About This Item
Skip To
material
EPDM rubber seal
PPO/PS blend (core)
PPO/PS blend housing
TPE seal
Ultracel® membrane
composite regenerated cellulose (CRC) membrane
epoxy adhesive
polyester screen
polypropylene screen
polyurethane adhesive
Quality Level
sterility
sterile; γ-irradiated
product line
Pellicon®
storage condition
room temperature (15-30°C)
parameter
4-8 L/min-m2 flow rate (Feed)
50 psi max. transmembrane pressure (3.5 bar) at 4-30 °C (Forward)
75 psi max. inlet pressure (5.1 bar) at 4-30 °C
technique(s)
ultrafiltration: suitable
L
41.1 cm (16.2 in.)
diam.
3.8 cm (1.5 in.)
filtration area
0.1 m2
screen size
, Type C screen (coarse screen)
size
0.1 m2 , with AseptiQuik® G connectors
volume
38 mL , in feed channel
68 mL , in permeate channel
impurities
≤5 ppm Meets TOC (in retentate effluent, after a WFI flush of 20 L/m2)
matrix
Ultracel®
pore size
30 kDa
pH range
2-13
fitting
inlet/outlet connection (Feed: AseptiQuik® G Connector)
inlet/outlet connection (Permeate: AseptiQuik® G Connector)
inlet/outlet connection (Retentate: AseptiQuik® G Connector)
Looking for similar products? Visit Product Comparison Guide
Related Categories
1 of 4
This Item | PCC030C05C | PCC300C01C | PCC030C30E |
|---|---|---|---|
| pore size 30 kDa | pore size 30 kDa | pore size 300 kDa | pore size 30 kDa |
| filtration area 0.1 m2 | filtration area 0.5 m2 | filtration area 0.1 m2 | filtration area 3 m2 |
| technique(s) ultrafiltration: suitable | technique(s) ultrafiltration: suitable | technique(s) ultrafiltration: suitable | technique(s) ultrafiltration: suitable |
| product line Pellicon® | product line Pellicon® | product line Pellicon® | product line Pellicon® |
| volume 38 mL , in feed channel, 68 mL , in permeate channel | volume 119 mL , in feed channel, 149 mL , in permeate channel | volume 40 mL , in feed channel, 66 mL , in permeate channel | volume 1288 mL , in feed channel, 1627 mL , in permeate channel |
| fitting inlet/outlet connection (Feed: AseptiQuik® G Connector), inlet/outlet connection (Retentate: AseptiQuik® G Connector), inlet/outlet connection (Permeate: AseptiQuik® G Connector) | fitting inlet/outlet connection (Feed: AseptiQuik® G Connector), inlet/outlet connection (Permeate: AseptiQuik® G Connector), inlet/outlet connection (Retentate: AseptiQuik® G Connector) | fitting inlet/outlet connection (Feed: AseptiQuik® G Connector), inlet/outlet connection (Permeate: AseptiQuik® G Connector), inlet/outlet connection (Retentate: AseptiQuik® G Connector) | fitting inlet/outlet connection (Feed: AseptiQuik® L Connector), inlet/outlet connection (Permeate: AseptiQuik® L Connector), inlet/outlet connection (Retentate: AseptiQuik® L Connector) |
General description
Application
Features and Benefits
Gamma sterilized and preseravtive-free - ready to process in minutes
True single-use, self-contained capusle - fast, safe, and flexible batch turnaround
Proven Ultracel® membrane and C screen - high recovery, superior mass transfer, solvent resistance
Pellicon® TFF proven performance - true linear scalability within Pellicon® TFF families
Packaging
Other Notes
Comprehensive documentation to support qualification, risk assessment and process optimization needs.
Consolidation of product specific testing, quality and regulatory information to simplify compliance requirements.
Convenient 24/7 access to up-to-date product information.
Legal Information
related product
Certificates of Analysis (COA)
Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.
Articles
Our overview of scalable tangential flow filtration for viral vector production will provide key considerations for developing and optimizing your downstream process.
Find best practices for using Pellicon® Capsules in ADC processing as well as data from two studies using Pellicon® Capsules and Pellicon® cassettes in the ADC manufacturing process.
What antibody drug conjugates are, how bioconjugates work, design considerations and ADC services for ADC manufacturing, including bioconjugation.
Learn more one the attenuated viral vaccines manufacturing process: cell culture, clarification, nuclease treatment, chromatography, and sterile filtration.
Related Content
Obtenga más información sobre el procesamiento posterior de mAb, más concretamente sobre la concentración y la diafiltración, y los productos asociados pertinentes.
Learn more on mAb downstream processing, more specifically concentration and diafiltration, and the relevant associated products.
Active Filters
Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.
Contact Technical Service


