MilliporeSigma
All Photos(1)

PXVVPPC50

Millipore

Pellicon® XL Cassette with Durapore® Membrane

filtration area 50 cm2, pore size 0.1 μm

Synonym(s):
Pellicon XL Filter Module Durapore 0.1 μm 50cm2
eCl@ss:
32031623
NACRES:
NB.24

material

PVDF membrane
polypropylene
polypropylene screen

Quality Level

feature

holdup volume 3.2 mL

manufacturer/tradename

Pellicon®

parameter

0.03–0.05 L/min recirculation rate
15 mL min. working volume
2.8 bar max. transmembrane pressure (40 psig)
5.5 bar max. inlet pressure (80 psi) at 50 °C

technique(s)

analytical sample preparation: suitable
protein purification: suitable

L

18.8 cm (7.4 in.)

W

3 cm (1.2 in.)

filtration area

50 cm2

membrane nominal area

50 cm2

gravimetric extractables

≤7.5 mg/device

matrix

Durapore®

pore size

0.1 μm nominal pore size
0.1 μm pore size

pH

1-11(cleaning)
1.5–9(continuous)

shipped in

ambient

Compare Similar Items

View Full Comparison

Show Differences

1 of 4

This Item
PXDVPPC50PXB010A50PXB300C50
feature

holdup volume 3.2 mL

feature

holdup volume 3.2 mL

feature

holdup volume 3.2 mL

feature

holdup volume 3.2 mL

parameter

0.03–0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C

parameter

0.03-0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C

parameter

0.03–0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C

parameter

0.03–0.05 L/min recirculation rate, 15 mL min. working volume, 2.8 bar max. transmembrane pressure (40 psig), 5.5 bar max. inlet pressure (80 psi) at 50 °C

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

technique(s)

analytical sample preparation: suitable, protein purification: suitable

filtration area

50 cm2

filtration area

50 cm2

filtration area

50 cm2

filtration area

50 cm2

matrix

Durapore®

matrix

Durapore®

matrix

Biomax®

matrix

Biomax®

General description

Device Configuration: Cassette
Filter Code: VVPP
Filter Type: Microfiltration

Features and Benefits

Type C screen (coarse screen)

Other Notes

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Analysis Note

Gravimetric Extractables: after a water flush

Legal Information

Durapore is a registered trademark of Merck KGaA, Darmstadt, Germany
Pellicon is a registered trademark of Merck KGaA, Darmstadt, Germany

Storage Class Code

12 - Non Combustible Liquids

WGK

WGK 1

Flash Point(F)

Not applicable

Flash Point(C)

Not applicable


Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Documents related to the products that you have purchased in the past have been gathered in the Document Library for your convenience.

Visit the Document Library

Difficulty Finding Your Product Or Lot/Batch Number?

Product numbers are combined with Pack Sizes/Quantity when displayed on the website (example: T1503-25G). Please make sure you enter ONLY the product number in the Product Number field (Example: T1503).

Example:

T1503
Product Number
-
25G
Pack Size/Quantity

Additional examples:

705578-5MG-PW

PL860-CGA/SHF-1EA

MMYOMAG-74K-13

1000309185

enter as 1.000309185)

Having trouble? Feel free to contact Technical Service for assistance.

Lot and Batch Numbers can be found on a product's label following the words 'Lot' or 'Batch'.

Aldrich Products

  • For a lot number such as TO09019TO, enter it as 09019TO (without the first two letters 'TO').

  • For a lot number with a filling-code such as 05427ES-021, enter it as 05427ES (without the filling-code '-021').

  • For a lot number with a filling-code such as STBB0728K9, enter it as STBB0728 without the filling-code 'K9'.

Not Finding What You Are Looking For?

In some cases, a COA may not be available online. If your search was unable to find the COA you can request one.

Request COA

Our team of scientists has experience in all areas of research including Life Science, Material Science, Chemical Synthesis, Chromatography, Analytical and many others.

Contact Technical Service