Skip to Content
MilliporeSigma

Skip To

RLI1MAG-92K

MILLIPLEX® Rat Liver Injury Panel

Configurable Rat Liver Injury 5-Plex Panel

Synonym(s):

liver injury biomarker panel for rats, rat drug safety liver panel, rat hepatotoxicity multiplex assay, rat liver enzyme panel, rat liver function assay

Sign In to View Organizational & Contract Pricing.

About This Item

UNSPSC Code:
12161503
NACRES:
NA.84
eCl@ss:
32161000
To order a Milliplex® kit, please search for your analyte of interest.


Product Name

MILLIPLEX® Rat Liver Injury Panel,

Quality Level

species reactivity

rat

packaging

pkg of 1 ea

manufacturer/tradename

Milliplex®

assay range

accuracy: 77-92%, sensitivity: 0.021-4.038 ng/mL
(MinDC+2SD), standard curve range: 0.02-15.0 ng/mL
(GSTα), standard curve range: 0.04-30.0 ng/mL
(5′-NT/CD73), standard curve range: 0.08-60.0 ng/mL
(GOT1), standard curve range: 0.10-75.0 ng/mL
(ARG1), standard curve range: 0.62-450.0 ng/mL
(SDH)

technique(s)

multiplexing: suitable

detection method

fluorometric (Luminex® xMAP® technology)

shipped in

wet ice

storage temp.

2-8°C

General description

5′NT/CD73 and ARG1 are markers of liver function and metabolic activity. GOT1 and SDH are enzymes released during hepatocellular injury, while GSTα reflects oxidative stress and detoxification. Together, these biomarkers provide a comprehensive view of liver damage and function in rat models.

Application

MILLIPLEX® Qualified assays undergo rigorous assay development, verification, and Quality Control testing to achieve optimal performance. Simultaneously analyze up to 5 analytes rat serum or plasma samples.

Analytes Included: 5′NT/CD73, ARG1, GOT1, GSTα, SDH

Assay Characteristics: Refer to the assay protocol for details on cross-reactivity, sensitivity, precision, and accuracy

Features and Benefits

Features:

  • Multiplex detection of 5 liver injury biomarkers in one assay
  • Magnetic bead-based format for efficient and reproducible processing
  • Compatible with rat serum, plasma, and tissue lysates
  • High sensitivity for early detection of hepatocellular damage
Benefits:

  • Conserves sample volume and reagents through multiplexing
  • Improves data quality and reproducibility with magnetic bead format
  • Enables early detection and monitoring of liver injury
  • Supports translational research in liver disease and toxicology

Legal Information

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Disclaimer

For research use only. Not for use in diagnostic procedures.

Label License/Sticker for Assay Product:

By opening the packaging containing this Assay Product (which contains fluorescently labeled microsphere beads authorized by Luminex Corporation) or using this Assay Product in any manner, you are consenting and agreeing to be bound by the End User Terms and Conditions and the End User License Agreement available at http://support.diasorin.com/end-user-terms-and-conditions/. If you do not agree to all of the terms and conditions, you must promptly return this Assay Product for a full refund prior to using it in any manner.

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
RV1MAG-26KRECYTMAG-65KRV2MAG-26K
species reactivity

rat

species reactivity

rat

species reactivity

rat

species reactivity

rat

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

manufacturer/tradename

Milliplex®

assay range

accuracy: 77-92%, standard curve range: 0.02-15.0 ng/mL
(GSTα), standard curve range: 0.08-60.0 ng/mL
(GOT1), standard curve range: 0.62-450.0 ng/mL
(SDH), sensitivity: 0.021-4.038 ng/mL
(MinDC+2SD), standard curve range: 0.10-75.0 ng/mL
(ARG1), standard curve range: 0.04-30.0 ng/mL
(5′-NT/CD73)

assay range

accuracy: 97-108%, intra-assay cv: <10%, standard curve range: 0.1-100 ng/mL
(CINC-1/GRO/KC, IL-6, MCP-1, PAI-1 (total)), standard curve range: 0.1-15 ng/mL
(VEGF), standard curve range: 0.1-20 ng/mL
(TNFα), standard curve range: 0.2-150 ng/mL
(TIMP-1), standard curve range: 0.3-200 ng/mL
(CTGF), standard curve range: 1.4-1,000 ng/mL
(Caveolin-1), inter-assay cv: <10%
(All other analytes), inter-assay cv: <15%
(CINC-1/GRO/KC, PAI-1 (total), TIMP-1, TNFα), inter-assay cv: <20%
(Caveolin-1)

assay range

accuracy: 80-131%, standard curve range: 0.2-1,000 pg/mL
(EGF), standard curve range: 12.2-50,000 pg/mL
(GM-CSF, IL-1α, IL-2, IL-12 (p70), IL-18), standard curve range: 14.6-60,000 pg/mL
(Leptin, IFNγ, GRO/KC/CINC-1), standard curve range: 2.4-10,000 pg/mL
(MIP-1α, IL-1β, IP-10, Fractalkine, TNFα), standard curve range: 24.4-100,000 pg/mL
(LIX, MIP-2), standard curve range: 29.3-120,000 pg/mL
(MCP-1), standard curve range: 4.9-20,000 pg/mL
(G-CSF, Eotaxin, IL-4, IL-13, IL-5, VEGF, RANTES), standard curve range: 7.3-30,000 pg/mL
(IL-10, IL-17A), standard curve range: 73.2-300,000 pg/mL
(IL-6)

assay range

accuracy: 67-92%, standard curve range: 0.1-40 ng/mL
(sICAM-1), standard curve range: 0.1-50 ng/mL
(sE-Selectin), standard curve range: 0.3-250 ng/mL
(Adiponectin), standard curve range: 0.7-500 ng/mL
(von Willebrand Factor (vWF))

Quality Level

200

Quality Level

200

Quality Level

200

Quality Level

200

detection method

fluorometric (Luminex xMAP)

detection method

fluorometric (Luminex® xMAP® technology)

detection method

fluorometric (Luminex® xMAP® technology)

detection method

fluorometric (Luminex® xMAP® technology)

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice

shipped in

wet ice


pictograms

Skull and crossbonesEnvironment

signalword

Danger

Hazard Classifications

Acute Tox. 3 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Sens. 1

Storage Class

6.1C - Combustible acute toxic Cat.3 / toxic compounds or compounds which causing chronic effects

wgk

WGK 3



Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Related Content

Multiplex toxicity assays enable researchers to simultaneously measure multiple toxicity biomarkers of various organs to gain a better understanding of toxicity. Explore how MILLIPLEX® multiplex toxicity assays are advancing research on liver injury, kidney toxicity, genotoxicity, and more.

See how multiplex assays, such as the Luminex® bead-based multiplex immunoassay MILLIPLEX® Rat Liver Injury Panel, enable researchers to simultaneously measure multiple hepatotoxic biomarkers and cytokines to expand knowledge on drug-induced liver injury processes.

View All Related Content

Nalini Govender et al.
Clinical and experimental reproductive medicine, 48(2), 124-131 (2021-05-25)
Approximately 30% of preeclamptic pregnancies exhibit abnormal liver function tests. We assessed liver injury-associated enzyme levels and circulating transforming growth factor beta (TGF-β) levels in an arginine vasopressin (AVP)-induced pregnant Sprague-Dawley rat model. Pregnant and non-pregnant Sprague-Dawley rats (n=24) received



Global Trade Item Number

SKUGTIN
RLI1MAG-92K04055977130737

Questions

  1. Is the Rat Liver Injury Panel (RLI1MAG-92K) kit cross-reactive to mouse or other mammalian species?

    1 answer
    1. The multi-species cross-reactivity data for the Rat Liver Injury Panel is attached. Please note that this is based on 4 samples from each species and standards were not tested to determine the amount of cross-reactivity. For samples below detection, the lack of signal may not necessarily indicate an absence of cross-reactivity and could be due to low levels in the few samples tested.

      Helpful?