Skip to Content
MilliporeSigma

Skip To

S200B10RE

Millipore® Stericup® Receiver Flask

filter capacity 1000 mL, pack of 12 ea

Synonym(s):

SC00B10RE

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
12 pkg
Check Cart for Availability
$133.00

About This Item

UNSPSC Code:
41104914
NACRES:
NB.24
eCl@ss:
32031623
Material:
polystyrene bottle

$133.00


Check Cart for Availability

Request more information
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


material

polystyrene bottle

Quality Level

product line

Stericup®

packaging

pack of 12 ea

parameter

45 °C max. temp.

description

2.4 mL (hold-up volume)

H

183 mm

diam.

45 mm

filter capacity

1000 mL

fitting

45 mm inlet thread(s), outlet bottle top (Universal)

compatibility

for use with Steritop Filter Units

shipped in

ambient

storage temp.

no temp limit

General description

This item is a direct replacement for SC00B10RE
Work with ease and filter with confidence with Stericup® and Steritop® Filtration Systems.

Stericup® Receiver Flasks include a click-seal confidence cap that enables a secure grip in wet and dry conditions. A tactile stop confirms the receiver bottle cap is perfectly sealed and a frosted writing surface on the receiver bottle enables convenient labelling solutions.

This Stericup® Receiver Flask with a 45 mm opening holds 1000 mL capacity.

Application

For Research Use Only
Stericup® and Steritop® systems are designed to reduce foaming and protein denaturation while maximizing flow and can be used for sterile vacuum filtration of aqueous solutions such as tissue culture media and biological fluids.

  • Tissue culture media +/- additives
  • Buffers
  • Biological solutions

Features and Benefits

  • Click seal cap is flanged and modified to enable a firm grip in wet or dry conditions—and a tactile stop confirms secure closure. Worry less about the possibility of spilling or contamination of sterilized contents.
  • Frosted, ample writing surface on the receiver bottle and lighter cap color facilitate clear labelling to improve legibility and reduce unreadable smears.
  • Click seal cap rests on the side to avoid risk of contamination.
  • Receiver bottles are stackable to save storage space.

Legal Information

Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
Stericup is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
S200B02RES200B05RES2VPT10RE
material

polystyrene bottle

material

polystyrene bottle

material

polystyrene bottle

material

polyethersulfone membrane, polystyrene bottle, polystyrene funnel(s), polystyrene housing

parameter

45 °C max. temp.

parameter

45 °C max. temp.

parameter

45 °C max. temp.

parameter

max. temp. at 45 °C

compatibility

for use with Steritop Filter Units

compatibility

for use with Steritop Filter Units

compatibility

for use with Steritop Filter Units

compatibility

-

fitting

45 mm inlet thread(s), outlet bottle top (Universal)

fitting

45 mm inlet thread(s), outlet bottle top (Universal)

fitting

45 mm inlet thread(s), outlet bottle top (Universal)

fitting

inlet funnel, 45 mm outlet thread(s)

packaging

pack of 12 ea

packaging

pack of 12 ea

packaging

pack of 12 ea

packaging

pack of 12 ea

Quality Level

400

Quality Level

400

Quality Level

400

Quality Level

400


Still not finding the right product?




Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Articles

Select the right sterile filter by media, volume, and application.





Global Trade Item Number

SKUGTIN
S200B10RE04054839116353

Questions

1–10 of 16 Questions  
  1. Are Stericup and Steritop filters DNAse free?

    1 answer
    1. Stericup and Steritop are not DNAse free. These are meant for Research Use Only and are not cGMP products.

      Helpful?

  2. The User Guide says “Use only glass or plastic bottles designed for vacuum applications”. Can you specify which bottles are compatible?

    1 answer
    1. Steritop® Quick Release bottle top units require a vacuum-rated receiver bottle with either a GL33 or GL45 mm closure thread as specified. Steritop® E bottle top units require a vacuum-rated receiver bottle with a GL45 mm closure thread. Bottles no larger than 2 L should be used.
      Glass bottles, GL33:
      • Wheaton media bottles (glass), 500 mL (Product Z364886)
      • Wheaton media bottles (glass), 1 L (Product Z364894)
      Glass bottles, GL45
      • Corning® glass media storage bottle, 125 mL (Product CLS1399125)
      • Corning® glass media storage bottle, 250 mL (Product CLS1399250)
      • Corning® glass media storage bottle, 500 mL (Product CLS1399500)
      • Corning® glass media storage bottle, 1 L (Product CLS13991L)
      • Pyrex® round media storage bottle, 500 mL (Product CLS1395500)
      • Pyrex® round media storage bottle, 1 L (Product CLS13951L)
      • KIMBLE® KIMAX® Media bottle, 250 mL (Product DWK14395250)
      • KIMBLE® KIMAX® Media bottle, 500 mL (Product DWK14395500)
      • KIMBLE® KIMAX® Media bottle, 1 L (Product DWK143951000)
      Plastic (pre-sterile) bottles, GL45:
      • Stericup® Quick Release Receiver flask, 250 mL (Product S200B02RE)
      • Stericup® Quick Release Receiver flask, 500 mL (Product S200B05RE)
      • Stericup® Quick Release Receiver flask, 1000 mL (Product S200B10RE)

      Helpful?

  3. Can Stericup® and Steritop® filters be reused?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single use, disposable processing.

      Helpful?

  4. What is the maximum vacuum pressure for filtration?

    1 answer
    1. 700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)

      Helpful?

  5. Which type of pump should be used with Stericup® and Steritop® vacuum filters?

    Which type of pump should be used with Stericup® and Steritop® vacuum filters?

    1 answer
    1. We recommend our Chemical Duty Pump: https://www.sigmaaldrich.com/product/mm/wp6111560

      Helpful?

  6. What Bacterial Endotoxins Test is used?

    1 answer
    1. The test method used complies with USP 85 and EP 2.6.14 to ensure the absence of endotoxin in our products.

      Helpful?

  7. What leachables are detected during filtration processes using Stericup® filters?

    1 answer
    1. We have not performed extractables/leachables studies for our Stericup® filters.

      Helpful?

  8. Are Stericup® and Steritop® filters GMP-certified?

    1 answer
    1. No, Stericup® and Steritop® devices are not GMP-approved.

      Helpful?

  9. Can we filter oil-type liquids with Stericup® filters?

    Can we filter oil-type liquids with Stericup® filters?

    1 answer
    1. Likely not, due to pore size/possible fouling/chemical compatibility. Refer to our guide, "Chemical compatibility of filter components": https://www.sigmaaldrich.com/deepweb/assets/sigmaaldrich/product/documents/302/855/membrane-chemical-compatibility-ds2532en-ms.pdf

      Helpful?

  10. What is the chemical compatibility of the various Stericup® and Steritop® filters?

    What is the chemical compatibility of the various Stericup® and Steritop® filters?

    1 answer
    1. Helpful?

1–10 of 16 Questions  

Reviews

No rating value

Active Filters