Skip to Content
MilliporeSigma

Skip To

S2EM004M99

Multiscreen® 96 well Plate, hydrophobic PVDF membrane

pore size 0.45 μm, sterile

Synonym(s):

Hydrophobic 96-Well Plate, PVDF 96-Well Plate

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Pack SizeSKUAvailabilityPrice
10 ea

Estimated to ship TODAY

$454.00

About This Item

UNSPSC Code:
41104923
NACRES:
NB.22
eCl@ss:
32039006
Material:
Durapore PVDF membrane, acrylic plate
Pore size:
0.45 μm pore size
Sterility:
sterile

$454.00


Estimated to ship TODAYDetails


Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Level

material

Durapore PVDF membrane, acrylic plate

description

Sterile, white 96-well filter plate with 0.45 um pore size Hydrophobic PVDF membrane for ELISPOT Assays. Comes in a pack of 10.

sterility

sterile

usage

Manual

packaging

pkg of 10 plates

manufacturer/tradename

MultiScreen®

technique(s)

ELISPOT: suitable, cell based assay: suitable

filtration area

0.28 cm2

plate size

96 wells

working volume

50-250 μL

matrix

Immobilon®-P

pore size

0.45 μm pore size

compatibility

manifold only

shipped in

ambient

storage temp.

10-30°C

General description

Filter Code: IP

Application

MultiScreen®-IP Filter Plate, 0.45 μm, white, sterile has been used in the enzyme-linked immunospot (ELISPOT) assay.[1][2][3]

Physical form

Color Code: White

Other Notes

Automation Compatible: No

Legal Information

Immobilon is a registered trademark of Merck KGaA, Darmstadt, Germany
MULTISCREEN is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
MAIPN4550MSIPN4B10MSIPS4W10
manufacturer/tradename

MultiScreen®

manufacturer/tradename

MultiScreen®

manufacturer/tradename

MultiScreen®

manufacturer/tradename

MultiScreen®

sterility

sterile

sterility

non-sterile

sterility

non-sterile

sterility

sterile

material

Durapore PVDF membrane, acrylic plate

material

Durapore PVDF membrane, clear acrylic plate, flat bottom wells

material

Durapore PVDF membrane, flat bottom wells, white Barex® plate (co-polymer)

material

Durapore PVDF membrane, flat bottom wells, white acrylic plate

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

pore size

0.45 μm pore size

working volume

50-250 μL

working volume

50-250 μL

working volume

50-250 μL

working volume

50-250 μL

packaging

pkg of 10 plates

packaging

pkg of 50 plates

packaging

pkg of 10 plates

packaging

pkg of 10 plates


Still not finding the right product?




Certificates of Analysis (COA)

Search for Certificates of Analysis (COA) by entering the products Lot/Batch Number. Lot and Batch Numbers can be found on a product’s label following the words ‘Lot’ or ‘Batch’.

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library


Protocols

Guidelines for various bioassays on the MultiScreen system, which makes it possible to carry out an assay from sample incubation to scintillation counting in a 96-well plate.

The ELISpot (Enzyme Linked Immuno-Spot) assay provides an effective method of measuring the antibody or cytokine production of immune cells on the single cell level.

Articles

ELISpot assay provides qualitative and quantitative information on immune responses, visualizing multiple secretory products from single responding cells.

Related Content

The ELISpot (Enzyme Linked Immuno-Spot) assay provides an effective method of measuring the antibody or cytokine production of immune cells on the single cell level. The popularity of this assay has seen resurgence in recent years as researchers attempt to gain a better understanding of immune responses in a variety of applications. The following protocol is an example of a typical ELISpot assay for quantifying the number cells producing interferon-gamma (IFN-γ) in response to antigen or non-specific activation using phytohemagglutinin (PHA). It may be optimized as necessary for other applications.


Sung-Ho Chang et al.
Cells, 9(5) (2020-05-24)
We investigated the immunogenicity of allogeneic human adipose-derived mesenchymal stem cells (ADSCs) through the production of alloreactive-CD8 T and -memory CD8 T cells, based on their human leukocyte antigen (HLA) expression. In surface antigen analysis, ADSCs do not express co-stimulatory
Sarah Côté-Bigras et al.
Clinical endocrinology, 80(2), 296-300 (2013-06-06)
While thyrotrophin receptor (TSHR) is recognized as the main autoantigen in Graves' disease (GD), the actual antigen specificity of T cells that infiltrate the thyroid and the orbit is unknown. Identifying T cell responses to TSHR peptides has been difficult
Daniela Frasca et al.
Vaccine, 34(25), 2834-2840 (2016-04-25)
The success of a vaccine in inducing a protective antibody response depends on the longevity of both long-lived plasma cells (PC) and memory B cells. We have previously shown that the in vivo antibody response to a new influenza vaccine



Global Trade Item Number

SKUGTIN
S2EM004M9904053252667800

Questions

1–2 of 2 Questions  
  1. Which specific plate is utilized in the ImmunoSpot M200 kit?

    1 answer
    1. The specific plate utilized in the ImmunoSpot M200 kit is the S2EM004M99, MultiScreen-IP Filter Plate.

      Helpful?

  2. Can S2EM004M99 be utilized with Biosys Bioreader 7000 for Elispot reading?

    1 answer
    1. The Biosys Bioreader 7000 has different versions, so it is important to confirm the specific model. If you have a 7000 V, it reads from above and will work with plates that need to be read from above. Regarding the specific plate S2EM004M99, it also needs to be read from above, making it compatible with the 7000 V model.

      Helpful?

Reviews

No rating value

Active Filters