pore size 0.22 μm, polyethersulfone membrane, filter capacity 500 mL, 33 mm outlet thread(s), pack of 12 ea

Synonym(s):

Steritop Threaded Bottle Top Filter, Steritop®-GP Quick Release Bottle Top Filter, bottle top sterile filter unit, bottle top vacuum filter, bottle top vacuum filtering unit

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
12 filters
Check Cart for Availability
$162.00

About This Item

UNSPSC Code:
41104914
NACRES:
NB.24
eCl@ss:
32031623
Pore size:
0.22 μm pore size
Filter capacity:
500 mL
Packaging:
pack of 12 ea
Material:
polyethersulfone membrane, polystyrene funnel(s), polystyrene housing

$162.00


Check Cart for Availability

Request more information
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Segment

material

polyethersulfone membrane, polystyrene funnel(s), polystyrene housing

product line

Steritop®

feature

hydrophilic

packaging

pack of 12 ea

parameter

45 °C max. temp.

description

2.4 mL (hold-up volume)

technique(s)

sterile filtration: suitable

H

148 mm

capacity

500 mL

diam.

12.5 cm

filter capacity

500 mL

filter diam.

73 mm

filtration area

40 cm2

matrix

Express PLUS

pore size

0.22 μm pore size

fitting

inlet funnel, 33 mm outlet thread(s)

shipped in

ambient

storage temp.

15-25°C

General description

Work with ease and filter with confidence with Stericup® and Steritop® Filtration Systems.

Stericup ® and Steritop ® sterile filtration devices use reliable, high-performance membranes for optimum sterile filtration of laboratory reagents, buffers, and media. These devices combine superior flow rates and throughput with low non-specific binding and a stable, no-tip design.

This Steritop ® 500 mL bottle top 0.22 μm pore size polyethersulfone (PES) membrane filter unit can be used on bottles with 33 mm openings, , designed for vacuum applications.

Application

For Research Use Only
Stericup® and Steritop® systems are designed to reduce foaming and protein denaturation while maximizing flow and can be used for sterile vacuum filtration of aqueous solutions such as tissue culture media and biological fluids.

  • Tissue culture media +/- additives
  • Buffers
  • Biological solutions

Legal Information

EXPRESS PLUS is a trademark of Merck KGaA, Darmstadt, Germany
Millipore is a registered trademark of Merck KGaA, Darmstadt, Germany
STERITOP is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
SCGPS02RES2GPT01RES2GPT10RE
description

pore size 0.22 μm, polyethersulfone membrane, filter capacity 500 mL, 33 mm outlet thread(s), pack of 12 ea

description

pore size 0.22 μm, polyethersulfone membrane, filter capacity 250 mL, 33 mm outlet thread(s), pack of 12 ea

description

pore size 0.22 μm, polyethersulfone membrane, filter capacity 150 mL, pack of 12 ea

description

pore size 0.22 μm, polyethersulfone membrane, filter capacity 1000 mL, pack of 12 ea

filter capacity

500 mL

filter capacity

250 mL

filter capacity

150 mL

filter capacity

1000 mL

pore size

0.22 μm pore size

pore size

0.22 μm nominal pore size, 0.22 μm pore size

pore size

0.22 μm pore size

pore size

0.22 μm pore size

material

polystyrene housing, polystyrene funnel(s), polyethersulfone membrane

material

polystyrene , polyethersulfone membrane

material

polystyrene funnel(s), polystyrene housing, polyethersulfone membrane

material

polystyrene funnel(s), polyethersulfone membrane, polystyrene housing

packaging

pack of 12 ea

packaging

pack of 12 ea

packaging

pack of 12 ea

packaging

pack of 12 ea

fitting

33 mm outlet thread(s), inlet funnel

fitting

33 mm outlet thread(s), inlet funnel

fitting

inlet funnel, 45 mm outlet thread(s)

fitting

inlet funnel, 45 mm outlet thread(s)

feature

hydrophilic

feature

holdup volume 2.4 mL, hydrophilic

feature

hydrophilic

feature

hydrophilic


Still not finding the right product?




Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

1–10 of 16 Questions  
  1. What is the bottle part number for SCGPS05RE?

    1 answer
    1. WHEATON® LAB 45™ Reagent Bottle, Clear Borosilicate Glass With Connection Neck (Catalog Number: 844026) is compatible for use with SCGPS05RE, the Millipore Steritop Threaded Bottle Top Filter.

      Helpful?

  2. What leachables are detected during filtration processes using Stericup® filters?

    1 answer
    1. We have not performed extractables/leachables studies for our Stericup® filters.

      Helpful?

  3. What tubing can be used with Stericup® and Steritop® vacuum filters?

    What tubing can be used with Stericup® and Steritop® vacuum filters?

    1 answer
    1. Stericup® and Steritop® filters are fitted with a 1/4” tube adapter. We recommend 3/16 in. (4.8 mm) ID silicone tubing to fit this tube adapter: https://www.sigmaaldrich.com/product/mm/xx7100004

      Helpful?

  4. Can Stericup® and Steritop® filters be used to prepare solutions that will be administered to patients?

    1 answer
    1. No, all Stericup® and Steritop® devices are Research Use Only.

      Helpful?

  5. What is the chemical compatibility of the various Stericup® and Steritop® filters?

    What is the chemical compatibility of the various Stericup® and Steritop® filters?

    1 answer
    1. Helpful?

  6. What is the difference between classic Stericup® filters and Stericup® “Quick Release” filters?

    1 answer
    1. Stericup® Quick Release, or “QR”, filters feature a connection between funnel filter and receiver bottle that requires only a quarter-turn release to facilitate funnel removal. These filters come fully engaged – there is no need to tighten before use. The receiver bottle cap has flanges on the top surface to improve grip, as well as a positive lock stop to ensure a leak-proof seal with the receiver bottle. Other improvements include a large, frosted writing surface on the receiver bottle and a lighter cap color to facilitate labelling, more prominent volume markings on the filtration funnel and receiver bottle, and a product label with a peel-off lot record strip on the bag for easy viewing in storage.

      Helpful?

  7. What is the expiration date of Stericup® and Steritop® filters?

    1 answer
    1. Typically 3 years from sterilization.

      Helpful?

  8. Can Stericup® bottles be placed inside freezers for long-term storage of media?

    1 answer
    1. You can successfully freeze and store many aqueous solutions (such as culture media) in Stericup® bottles at temperatures up to -20 °C (-4 °F). It is strongly recommended that you run a sample stability trial under your actual storage conditions prior to using Stericup® bottles for frozen storage.

      Helpful?

  9. What is the maximum vacuum pressure for filtration?

    1 answer
    1. 700 mm Hg (27.5” Hg, 0.9 bar) differential vacuum at 25 °C (77 °F)

      Helpful?

  10. Can Stericup® and Steritop® filters be reused?

    1 answer
    1. All Stericup® and Steritop® filters were developed for single use, disposable processing.