About This Item
$154.00
Quality Segment
form
liquid
manufacturer/tradename
Chemicon®
technique(s)
cell culture | stem cell: suitable
input
sample type mesenchymal stem cell(s)
shipped in
dry ice
storage temp.
-10 to -25°C
Application
2. Cells to be frozen should be in late log phase growth.
3. Monolayers will need to be dissociated. After dissociation, cells are resuspended in Mesenchymal Stem Cell Expansion Medium (Cat. No. SCM015) and counted to determine viability and number.
4. Centrifuge cells at 300 x g for 3 min. Remove the medium above the pellet.
5. Resuspend the cells in Mesenchymall Stem Cell Freezing Medium at a concentration of ~4 x 106 cells/mL. Freeze 1 mL of cells/vial. After the cells have been resuspended and aliquoted into appropriate cryogenic storage vials, they can be placed in a freezing container and the normal freeze down procedure should be started within five minutes.
6. Cells must be stored at or below -80°C. For long term storage the cells should be stored in ultra-low temperature freezer (-150°C), or in liquid nitrogen (-196°C).
7. Thawing of cryopreserved cells should be as follows:
a. Do not thaw the cells until the recommended medium and appropriate plasticware and/or glassware are on hand.
b. Thaw cells quickly in a 37°C water bath. Important: Do not vortex the cells.
c. Sterilize vial by rinsing with 70% ethanol.
d. In a laminar flow hood, use a 1 or 2 mL pipette to transfer the cells to a sterile 15 mL conical tube. Be careful to not introduce any bubbles during the transfer process.
e. Using a 10 mL pipette, slowly add dropwise 9 mL of Mesenchymal Stem Cell Expansion Medium (pre-warmed at 37°C) to the 15 mL conical tube. IMPORTANT: Do not add the whole volume of medium at once to the cells. This may result in decreased cell viability due to osmotic shock.
f. Gently mix the cell suspension by slow pipeting up and down twice. Be careful to not introduce any bubbles. IMPORTANT: Do not vortex the cells.
g. Centrifuge the tube at 300 x g for 2-3 minutes to pellet the cells.
h. Decant as much of the supernatant as possible
i. Resuspend the cells in a total volume of 10 mL of Mesenchymal Stem Cell Expansion Medium (pre-warmed at 37°C).
j. Plate the cell mixture onto a 10-cm tissue culture plate.
k. Incubate the cells at 37°C in a 5% CO2 humidified incubator.
l. The next day, exchange the medium with fresh Mesenchymal Stem Cell Expansion Medium (pre-warmed to 37°C). Exchange with fresh medium every two to three days thereafter.
m. When the cells are approximately 80% confluent, they can be dissociated with Accutase® (Cat. No. SCR005) and passaged or alternatively frozen for later use.
Physical form
Preparation Note
Legal Information
Disclaimer
1 of 1
This Item | |||
|---|---|---|---|
| description The Mesenchymal Stem Cell Freezing Medium (1x) has been optimized & validated for Stem cell culture. This medium is available in a 50ml format. | description The Mesenchymal Stem Cell Expansion Medium (1x) has been optimized & validated for Stem cell culture. This medium is available in a 500mL format. | description - | description Xeno-free mesenchymal stem cell media specially formulated for the rapid expansion of human mesenchymal stem cells isolated from a variety of sources, including adipose and bone marrow tissues. |
| technique(s) cell culture | stem cell: suitable | technique(s) cell culture | stem cell: suitable | technique(s) cell culture | stem cell: suitable | technique(s) cell culture | stem cell: suitable |
| form liquid | form liquid | form liquid | form liquid |
| shipped in dry ice | shipped in dry ice | shipped in - | shipped in dry ice |
| storage temp. -10 to -25°C | storage temp. -10 to -25°C | storage temp. - | storage temp. -10 to -25°C |
| Quality Level 100 | Quality Level 200 | Quality Level 100 | Quality Level 100 |
| manufacturer/tradename Chemicon® | manufacturer/tradename Chemicon® | manufacturer/tradename - | manufacturer/tradename Chemicon® |
Storage Class
10 - Combustible liquids
WGK
WGK 1
Flash Point (°F)
Not applicable
Flash Point (°C)
Not applicable
Choose from one of the most recent versions:
Already Own This Product?
Find documentation for the products that you have recently purchased in the Document Library.