UFC703008

Centricon® Plus Centrifugal Filter

MWCO 30 kDa, sample volume 15-70 mL, regenerated cellulose membrane

Synonym(s):

Centrifuge concentrator

Sign In to View Organizational & Contract Pricing.

Select a Size

Change View
Size/SKUAvailabilityPrice
8 filters
Check Cart for Availability
$344.00

About This Item

UNSPSC Code:
41104916
NACRES:
NB.24
eCl@ss:
36100101
Material:
polypropylene cap, polypropylene cup (for concentrate/retentate), polypropylene cup (for filtrate collection), polypropylene cup (for sample filter), regenerated cellulose membrane
Pore size:
30 kDa MWCO
Working volume:
≤70 mL , 15—70 mL
Sterility:
non-sterile
Packaging:
pkg of 8 filter

$344.00


Check Cart for Availability

Request a Custom Order
Technical Service
Need help? Our team of experienced scientists is here for you.
Let Us Assist


Quality Segment

material

polypropylene cap, polypropylene cup (for concentrate/retentate), polypropylene cup (for filtrate collection), polypropylene cup (for sample filter), regenerated cellulose membrane

sterility

non-sterile

product line

Amicon®

feature

holdup volume 75 μL

packaging

pkg of 8 filter

manufacturer/tradename

Amicon® Ultra, Centricon®

parameter

15-70 mL sample volume

technique(s)

protein extraction: suitable, protein purification: suitable

L

121 mm

diam.

6 cm

filtration area

19 cm2

working volume

≤70 mL , 15—70 mL

pore size

30 kDa MWCO

application(s)

sample preparation

shipped in

ambient

General description

Filter Type: Ultrafiltration
The Centricon Plus-70 centrifugal filter is a disposable, single-use device designed for rapid processing of aqueous biological solutions in volumes ranging from 15 to 70 mL. It is compatible with swinging-bucket centrifuges only. The Centricon Plus-70 device can concentrate most 70 mL solutions down to 350 μL in just 25 minutes (some solutions may take slightly longer).


•90% typical recovery
•50X to 200X concentration
•Low hold-up volume
•Polypropylene housing minimizes binding
•Deadstop prevents spinning to dryness
•Ready to use. Nothing to assemble


Applications:
•Concentrating and desalting chromatography column eluates
•Concentrating monoclonal antibodies
•Concentrating proteins or viruses from culture supernatants
•Clarifying tissue homogenates and cell lysates
•Buffer exchange or diafiltration

Application

30 kDa cutoff, 15 mL to 70 mL volume

Features and Benefits

Minimum Final Concentrate Volume: 350 µL

Physical form

Color Code: Clear

Legal Information

Amicon is a registered trademark of Merck KGaA, Darmstadt, Germany
CENTRICON is a registered trademark of Merck KGaA, Darmstadt, Germany
ULTRACEL is a registered trademark of Merck KGaA, Darmstadt, Germany

Compare Similar Items

View Full Comparison

Show Differences

1 of 1

This Item
UFC701008UFC710008MRCPRT010
description

MWCO 30 kDa, sample volume 15-70 mL, regenerated cellulose membrane

description

MWCO 10 kDa, sample volume 15-70 mL, regenerated cellulose membrane

description

MWCO 100 kDa, sample volume 15-70 mL, regenerated cellulose membrane

description

NMWCO 10 kDa, Ultracel® regenerated cellulose membrane (low binding), sample volume 0.5 mL

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

sterility

non-sterile

parameter

15-70 mL sample volume

parameter

15-70 mL sample volume

parameter

15-70 mL sample volume

parameter

0.5 mL sample volume

pore size

30 kDa MWCO

pore size

10 kDa MWCO

pore size

100 kDa MWCO

pore size

10 kDa NMWCO

manufacturer/tradename

Centricon®, Amicon® Ultra

manufacturer/tradename

Amicon® Ultra, Centricon®

manufacturer/tradename

Centricon®, Amicon® Ultra

manufacturer/tradename

Microcon®

material

polypropylene cup (for sample filter), polypropylene cap, polypropylene cup (for concentrate/retentate), regenerated cellulose membrane, polypropylene cup (for filtrate collection)

material

polypropylene cup (for filtrate collection), polypropylene cap, polypropylene cup (for concentrate/retentate), regenerated cellulose membrane, polypropylene cup (for sample filter)

material

polypropylene cup (for concentrate/retentate), polypropylene cap, polypropylene cup (for filtrate collection), regenerated cellulose membrane, polypropylene cup (for sample filter)

material

Ultracel® regenerated cellulose membrane (low binding), silicone O-ring (medical-grade), polyacetal base (membrane support), polycarbonate device top, polypropylene tube (for filtrate/concentrate)

working volume

15—70 mL , ≤70 mL

working volume

≤70 mL , 15—70 mL

working volume

≤70 mL , 15—70 mL

working volume

0.5 mL


Still not finding the right product?


Storage Class

10-13 - German Storage Class 10 to 13



Choose from one of the most recent versions:

Certificates of Analysis (COA)

Lot/Batch Number

It looks like we've run into a problem, but you can still download Certificates of Analysis from our Documents section.

If you need assistance, please contact Customer Support

Already Own This Product?

Find documentation for the products that you have recently purchased in the Document Library.

Visit the Document Library



Questions

  1. What is the maximum recommended milligram amount of antibody per 70mL 30K in order to prevent the protein from crashing out?

    1 answer
    1. There is no upper limit for protein load in the Amicons, but researchers must be aware of the solubility of their target protein and empirically determine optimal running conditions.